Page 42 of 48
III.Temperature setting
1.
Under the mode of comfort or Eco (excluding anti-freezing mode), temperature is adjustable.
Press
+
or
-
to choose the desired temperature for comfort mode between 5°C and 29°C. The
temperature difference between mode ECO and mode comfort is 3.5°C, so the temperature
range of mode ECO is between 1.5°C and 25.5°C.
2. Press other buttons except
+/-
to finish the setting, or after 5 seconds it will automatically save.
3. When the room temperature is higher than the selected temperature, the heater will stop
heating.
IV. Setting menu (MENU)
Press
MENU
to enter setting menu interface.
Press
+ / -
to choose from time setting
, program mode setting
,
Window detection mode
, keyboard lock setting
. The selected icon will flash while other
icons keep on.
Press
MENU
to exit the setting menu or after 30 seconds it will automatically exit and go back to
working interface.
1. Time setting
Press
MENU
to enter setting menu interface, and
+ / -
to select the time setting
. When
is flashing, press
OK-boost
to enter time setting.
Press
+ / -
to adjust the hour between 00-23.
Press
OK-boost
to confirm hour setting and move to minute setting (00~59).
Press
OK-boost
to confirm minute setting and move to day of week setting (1~7).
Press
OK-boost
to confirm or after 30 seconds, it will automatically save and go back to working
interface.
2. Program mode setting
Under program mode, you can choose from 7 pre-set 24-hour programs (P1~P7) for each day of
week. The 7 pre-set 24-hour programs (P1~P7) are programmable. For each hour, you can
choose between comfort mode or economic mode.
Under program mode, the default setting for day 1 to 7 of the week are as follows:
day 1 to day 5: work with P1,
day 6 to day 7: work with P3.
Содержание OCEAISH1750W0