Page 31 of 48
- The unit must be connected to a standard wall box
placed at least 60 cm from the floor.
- The appliance must not be connected to an outlet
with a power plug.
- The appliance must be supplied through a residual
current device (RCD) having a rated residual
operating current not exceeding 30 mA.
- The appliance must not be connected to the earth
wire (yellow and green wire).
ELECTRICAL CONNECTION
Blue or light gray wire connect to Neutral (230V)
Brown or red wire connect to Phase (230V)
Black wire connect to pilot wire. (Optional function to
use in case of control by pilot wire box)
- In the absence of pilot wire, insulate the bare end
of the black wire to prevent electrical contact with the
other wires or ground.
WALL-MOUNTED KITS (not provided)
Description
Drawing
Spec
QTY
Screw
4 x 30 mm
8
Wall plug
Φ8
8