background image

 

28 

EN

 

resetting  of  the  thermal  cutout,  this  appliance  must  not 
be  supplied  through  an  external  switching  device,  such 
as  a  timer,  or  connected  to  a  circuit  that  is  regularly 
switched on and off by the utility. 

 

The  heater  must  not  be  located  immediately  below  a 
socket-outlet. 

 

Means for disconnection having a contact separation in 
all  poles  must  be  incorporated  in  the  fixed  wiring  in 
accordance with the wiring rules. 

 

For  correct  installation  on  the  wall,  thanks  to  refer  to 
‘Installation on wall’ part. 

 

Fixed  heaters  are  to  be  installed  so  that  switches  and 
other  controls  cannot  be  touched  by  a  person  in  the 
bath or shower. 

 

Connect  the  two  conductors  and  the  pilot  wire  of  the 
supply  cord  to  a  connection  box  in  respecting  the 
following polarities:

 

- Live: Brown

- Neutral: Blue 

- Pilot wire: Black 

 

This heater is filled with a precise quantity of special oil. 
Repairs requiring opening of the oil container are only to 
be made by the manufacturer or his service agent who 
should be contacted if there is an oil leak; 

 

When  scrapping  the  heater,  follow  the  regulations 
concerning the disposal of oil. 

 

WARNING:  In  order  to  avoid  overheating,  do  not  cover 
the heater.  

 

Warning: this product shall be installed in the volume 2 

Содержание OCEAIFC1000W

Страница 1: ...OCEAIFC1000W OCEAIFC1400W OCEAIFC1800W MANUEL D INSTRUCTIONS Radiateur aluminium fluide caloporteur INSTRUCTION MANUAL Aluminum Radiator...

Страница 2: ...enfants de moins de 3 ans moins qu ils ne soient sous une surveillance continue Les enfants g s entre 3 ans et 8 ans doivent uniquement mettre l appareil en marche ou l arr t condition que ce dernier...

Страница 3: ...rs et autres dispositifs de commande ne puissent pas tre touch s par une personne dans la baignoire ou la douche Un moyen de d connexion du r seau d alimentation ayant une distance d ouverture des con...

Страница 4: ...le volume 2 ou hors volume d une salle de bain conform ment aux exigences de la norme fran aise d installation lectrique NF C 15 100 Note Le sch ma ci dessous est donn uniquement titre d exemple Nous...

Страница 5: ...ance de radiofr quence maximale 100mW Le soussign OCEANIC d clare que l quipement radio lectrique du type Chauffage lectrique r f OCEAIFC1000W OCEAIFC1400W OCEAIFC1800W est conforme la directive 2014...

Страница 6: ...24 OCEAIFC1400W 1400W 230V 50Hz Class II IP24 OCEAIFC1800W 1800W 230V 50Hz Class II IP24 III Installation D terminez l emplacement ad quat L appareil doit tre uniquement utilis et install en position...

Страница 7: ...l appareil et les murs le sol les meubles rideaux voir les dessins ci dessous 1 Percer les trous dans le mur en suivant les instructions Assurez vous que les distances comme indiqu es sur la figure c...

Страница 8: ...clavier Mise en marche veille R glage de la temp rature Appuyer sur ce bouton pour une augmentation rapide de la temp rature Ce bouton permet galement de s lectionner les plages horaires lors du r gl...

Страница 9: ...fin de pouvoir utiliser l appareil en mode programmation P1 P2 P3 vous devez r gler l heure et la date La programmation ne peut tre effectu e qu apr s le r glage de l heure Pour la modification de l h...

Страница 10: ...emp ratures du mode ECO et CONFORT sont li es La modification de l une des deux entraine la modification automatique de l autre la temp rature du mode ECO est toujours 3 5 C inf rieure celle du mode C...

Страница 11: ...Mode Confort Signifie Mode Eco Signifie Mode Hors Gel Une fois votre choix fait appuyer sur pour passer l heure suivante Si vous avez fait une erreur vous pouvez revenir au r glage de l heure pr c de...

Страница 12: ...edi et dimanche Utiliser pour choisir le mode de fonctionnement de l heure correspondante Signifie Mode Confort Signifie Mode Eco Signifie Mode Hors Gel Une fois votre choix fait appuyer sur pour pass...

Страница 13: ...s la personnalisation des 24h termin es appuy sur pour confirmer le r glage des heures et passer au r glage du jour suivant ainsi de suite jusqu avoir Une fois votre choix fait appuyer sur pour passer...

Страница 14: ...n est effectu e pendant 1 min le clavier se verrouille automatiquement Appuyer sur ensemble pour le d verrouiller L ic ne s affiche uniquement quand l appareil chauffe V Nettoyage maintenance D conne...

Страница 15: ...liser de d tergent d agents chimiques ou de solvants car cela pourrait endommager les parties plastiques OCEANIC 120 126 Quai de Bacalan CS 11584 33000 Bordeaux IMPORTED BY A M C 123 QUAI JULES GUESDE...

Страница 16: ...indicative Puissance thermique maximale continue la puissance thermique nominale la puissance thermique minimale En mode veille Caract ristique Caract ristique Unit Symbole Valeur Puissance thermique...

Страница 17: ...indicative Puissance thermique maximale continue la puissance thermique nominale la puissance thermique minimale En mode veille Caract ristique Caract ristique Unit Symbole Valeur Puissance thermique...

Страница 18: ...indicative Puissance thermique maximale continue la puissance thermique nominale la puissance thermique minimale En mode veille Caract ristique Caract ristique Unit Symbole Valeur Puissance thermique...

Страница 19: ...18 FR T l charger l application Oceanic et cr ez votre identificant et mot de passe...

Страница 20: ...19 FR Enregistrement Connexion par E mail Connexion par telephone...

Страница 21: ...20 FR Mode de connexion rapide Tous les radiateurs de votre installation se connectent en une seule fois...

Страница 22: ...21 FR...

Страница 23: ...22 FR Connexion individuelle Connexion un par un des radiateurs de votre installation...

Страница 24: ...23 FR S il vous pla t revenir oceanic APP pour continuer le r glage...

Страница 25: ...24 FR...

Страница 26: ...25 FR Probl me de connexion...

Страница 27: ...26 FR Aide...

Страница 28: ...and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction...

Страница 29: ...ed heaters are to be installed so that switches and other controls cannot be touched by a person in the bath or shower Connect the two conductors and the pilot wire of the supply cord to a connection...

Страница 30: ...om receiving a bath or a shower and socket outlets lower or equal to 32 A the circuit corresponding must be protected by a device with differential residual current RCD lower or equal to 30 mA FOR HOU...

Страница 31: ...adjustment via digital display l Clock l Weekly calendar l 2 modes of use o Manual o Automatic with weekly presetting 24h timer custom setting 7 different daily presets 6 orders pilot wire l Frost pr...

Страница 32: ...300 OCEAIFC1400W 500 OCEAIFC1800W 700 2 Fit the fasten tube in the hole and fit the bracket on the wall with screws 3 Hang the unit on the bracket gently after ensuring the unit is right fixed turn th...

Страница 33: ...ng for quick decreasing Backward the hour in 24 hour program setting This button is used to select different operating modes or different settings Pressing this button for 5 seconds resets the WIFI se...

Страница 34: ...conds to modify the clock 4 Function setting 1 Press to choose the mode or the program 2 Press to choose the temperature Different modes and preprogrammed programs Comfort mode Setting temp from 5 to...

Страница 35: ...Weekend 5 Program modification P1 When under program press once the symbol and the symbol first hour start flashing Press to choose the operating mode of the corresponding time Means Mode Confort Mean...

Страница 36: ...o the previous time setting by pressing Once 24h customization is complete press to confirm the setting and exit the menu The last 2 days of the week are displayed on the screen You are adjusting the...

Страница 37: ...to confirm the setting of the hours and move to the next day setting is displayed on the screen corresponding to Tuesday Perform the same operation as before to set the modes for each hour of the day...

Страница 38: ...hen in Comfor 1 or Confort 2 the temperature can t get set 9 Windows detector function Press to turn on off the windows function when the logo display in the screen it means window function is on If t...

Страница 39: ...his could create a fire and or electrical hazard We also recommend the periodic cleaning of this appliance by lightly running a vacuum cleaner nozzle over the guards to remove any dust or dirt that ma...

Страница 40: ...indicative Maximum continuous heat output At nominal heat output At minimum heat output In standby mode Item Item Unit Symbol Value Heat output Type of heat input for electric storage local space heat...

Страница 41: ...indicative Maximum continuous heat output At nominal heat output At minimum heat output In standby mode Item Item Unit Symbol Value Heat output Type of heat input for electric storage local space heat...

Страница 42: ...indicative Maximum continuous heat output At nominal heat output At minimum heat output In standby mode Item Item Unit Symbol Value Heat output Type of heat input for electric storage local space heat...

Страница 43: ...42 EN Download the Oceanic app and create your user name and password...

Страница 44: ...43 EN Sign up E mail sign up Mobile sign up...

Страница 45: ...44 EN Connection Quick connect mode...

Страница 46: ...45 EN Connection Hotspot mode...

Страница 47: ...46 EN Please go back to oceanic APP to continue setting...

Страница 48: ...47 EN...

Страница 49: ...48 EN Connection failure...

Страница 50: ...49 EN Help...

Страница 51: ......

Страница 52: ...www oceanic eu...

Отзывы: