background image

Sauna & Steam

Oceanic Saunas  01902 450 550  sales

@oceanic-saunas.co.uk www.oceanic-saunas.co.uk

13

Sauna Heater Manual

10.  Trouble shooting Guide

Please Note that we recommend a suitably qualified person carries out all repairs.

Trouble description 

Cause 

Solutions 

Overheat LED is on

1. The high tempeature cut off 

has been tripped

1.Remove the plastic casing 

around the temperature 

sensor and press the black 

button (you should hear a 

click) to reset the overheat 

sensor.

Maintenance

We recommend that you inspect the sauna heater on a regular basis for any signs of deterioration 

of the condition, pay particular attention to both the fastenings, the condition of the wiring and 

the electrical elements. 

Note if the rocks have started to crumble this can cause the elements to overheat and they should 

be changed for new rocks. We recommend commercial operators to change the rocks at least 

once very 12 months.

10.1.  Sauna Heaters & Sauna Cabins Maintenance 

All Sauna products supplied by Direct Saunas Limited and Oceanic Saunas are for use in an indoor 

environment such as a domestic house or a club building and should not be used in any other 

circumstances.  

10.2.  Sauna Maintenance 

Dependant upon how regularly the sauna cabin is being used a series of maintenance checks 

should be performed on the sauna cabin and sauna heater to ensure that they are kept in a good 

state of repair.  

For commercial users we recommend these inspections be conducted on a monthly basis by a 

member of the maintenance staff and detailed records kept. 

For domestic use these checks should be carried out every 6 months. 

Any obvious deterioration should be noted immediately if noticed in between maintenance 

checks and should be resolved before continuing use of the products.   

Under no circumstances do we recommend operating the sauna cabin if any electrical wiring 

is considered to be hazardous, please contact your electrician or our technical department for 

assistance.  

10.3.  Maintenance Checks 

Please note all maintenance checks should be preformed whilst the sauna cabin and sauna heater 

are cold.  

10.4.  Sauna Heater:

Ensure the heater has been correctly disconnected from the mains electricity before these checks 

are conducted

1) 

Check sauna elements for signs of deterioration. Report any signs of deterioration to the 

supplier 

Содержание BIC CS20

Страница 1: ...c Ltd Pountney Street Wolverhampton WV2 4HX Phone 01902 450 550 sales oceanic saunas co uk www oceanic saunas co uk Sauna Steam COMPACT SAUNA HEATER Built in Controls with Temperature Sensor Assembly...

Страница 2: ...na Heater Parameters 5 5 1 Sauna Heater Parts Description 5 5 2 Detailed Circuit Diagram 6 5 3 Control Panel Description 7 6 Installation 8 6 1 Pre installation checklist 8 6 2 Minimum Clearances 9 6...

Страница 3: ...hese suffering heart disease high blood pressure diabetes or not in good health are advised to seek medical opinion before using a sauna room Do not smoke in the sauna room Avoid using the sauna room...

Страница 4: ...co uk www oceanic saunas co uk 4 L N Isolated Single Phase 230V Mains Power In 2 2 5 3kW Sauna Heater Heating element Sauna Heater Manual 4 1 Basic Circuit Diagram CS20 CS30 Circuit diagram N L 1 Temp...

Страница 5: ...arameter Model Power KW Voltage V Phase N Current A Heater Elements Sauna Stone kg Dimensinos LxWxH mm CS20 2 230 1 9 1 12 14 410 x 210 x 540 CS25 2 5 230 1 11 1 12 14 CS30 3 230 1 13 1 12 14 5 1 Saun...

Страница 6: ...ram Sensor HEAT ELEMENT INPUT 230V 1N 50 60Hz N L Controller Controller Circuit board Switch C F Display Switch F JP1 JP4 TEMP JP3 TIME JP1 Fahrenheit JP2 Centigrade JP3 Display Time JP4 Display Tempe...

Страница 7: ...ure 7 Overheat LED Indicator LED to signal that heater has overheated reset manually inside the temperature sensor 8 Temperature LED Indicator LED to signal the digital display is showing the temperat...

Страница 8: ...board Circuit board 2 Bracket Bracket 3 Cover Protects the electronics 4 Heat resistance Detects temperature 5 High Temp cut off switch When temperature in sauna room exceed 120 oC 6 Temperature Senso...

Страница 9: ...t install the sauna heater on the floor or in a cabinet vi Do not cover the sauna heater back with asbestos cement or similar material vii The wire which enters the sauna room must be type 60245 IEC 6...

Страница 10: ...00 Minimum clearance distances Minimum clearance distances 210 100 50 20 Min 180 Min 1100 50 3mm gap between screw head and wall All sizes in mm Supporting Screw 6mm x 40mm 4pcs 3 5 150 600 7 2 Instal...

Страница 11: ...cating the temperature sensor input inside the heater 1800 Temperature Sensor min 500 7 4 Installing the temperature sensor i Install the temperature sensor as in the diagram below ii Open the cover w...

Страница 12: ...epending upon use 9 Testing and Operation i Turn the power on to the heater using the IP rated rocker switch ii Turn the heater on using the on off button on the control panel iii The default time wil...

Страница 13: ...onment such as a domestic house or a club building and should not be used in any other circumstances 10 2 Sauna Maintenance Dependant upon how regularly the sauna cabin is being used a series of maint...

Страница 14: ...rms to the clearance distances stated in the sauna heater manual Check for any signs of charring and replace the heater guard if it is showing signs of disrepair vii The sauna cabin should be kept in...

Отзывы: