Sauna & Steam
Oceanic Saunas 01902 450 550 sales
@oceanic-saunas.co.uk www.oceanic-saunas.co.uk
13
Sauna Heater Manual
10. Trouble shooting Guide
Please Note that we recommend a suitably qualified person carries out all repairs.
Trouble description
Cause
Solutions
Overheat LED is on
1. The high tempeature cut off
has been tripped
1.Remove the plastic casing
around the temperature
sensor and press the black
button (you should hear a
click) to reset the overheat
sensor.
Maintenance
We recommend that you inspect the sauna heater on a regular basis for any signs of deterioration
of the condition, pay particular attention to both the fastenings, the condition of the wiring and
the electrical elements.
Note if the rocks have started to crumble this can cause the elements to overheat and they should
be changed for new rocks. We recommend commercial operators to change the rocks at least
once very 12 months.
10.1. Sauna Heaters & Sauna Cabins Maintenance
All Sauna products supplied by Direct Saunas Limited and Oceanic Saunas are for use in an indoor
environment such as a domestic house or a club building and should not be used in any other
circumstances.
10.2. Sauna Maintenance
Dependant upon how regularly the sauna cabin is being used a series of maintenance checks
should be performed on the sauna cabin and sauna heater to ensure that they are kept in a good
state of repair.
For commercial users we recommend these inspections be conducted on a monthly basis by a
member of the maintenance staff and detailed records kept.
For domestic use these checks should be carried out every 6 months.
Any obvious deterioration should be noted immediately if noticed in between maintenance
checks and should be resolved before continuing use of the products.
Under no circumstances do we recommend operating the sauna cabin if any electrical wiring
is considered to be hazardous, please contact your electrician or our technical department for
assistance.
10.3. Maintenance Checks
Please note all maintenance checks should be preformed whilst the sauna cabin and sauna heater
are cold.
10.4. Sauna Heater:
Ensure the heater has been correctly disconnected from the mains electricity before these checks
are conducted
1)
Check sauna elements for signs of deterioration. Report any signs of deterioration to the
supplier