4.1.1 Change the User and Admin passwords
Record the changes for future reference.
4.1.2 Unit Reset
Click this button to reset the ATA100 to factory default settings. You will be asked to confi rm
this operation.
4.1.3 VSWR Alert Setting
The ATA100 measures the VSWR Coeffi cient during transmission and will report an
“Impaired Radio” alert if the VSWR appears to be high. For installations where the antenna
performance is marginal it is possible to adjust the threshold to prevent the alert being
issued. If the “Impaired Radio” alert is being triggered along with an amber LED indication
select and press Change to view the adjustment pop-up.
Adjust the VSWR Threshold Value so that it is just above that of the Measured Value.
Do not select a value far above the Measured Value as this may prevent a warning of a
deteriorating antenna installation.
NOTE: A VSWR Alert is an indication that the Antenna installation is not performing
effi ciently. The antenna and cable should be checked carefully before making
any adjustment.
Содержание ATA100
Страница 1: ...Installation Manual English Class A AIS Transceiver www oceansignal com ATA100 ...
Страница 7: ...21 04 2020 912S 03333 01 05 7 ATA100 INSTALLATION MANUAL 1 5 Example Systems ...
Страница 12: ...ATA100 INSTALLATION MANUAL 12 912S 03333 01 05 21 04 2020 ...
Страница 24: ...TEMPLATES 22 ...
Страница 25: ...ALWAYS CHECK THE DIMENSIONS OF TEMPLATES BEFORE USING ...
Страница 26: ...ALWAYS CHECK THE DIMENSIONS OF TEMPLATES BEFORE USING 24 ...
Страница 27: ......
Страница 28: ...ALWAYS CHECK THE DIMENSIONS OF TEMPLATES BEFORE USING ...
Страница 29: ...TEMPLATES 27 ...
Страница 52: ...Ocean Signal Ltd Unit 4 Ocivan Way Margate CT9 4NN United Kingdom info oceansignal com www oceansignal com ...