000-40000-010-02-201307 

25

 

Appendix A 

Tera Term Software 

Tera Term is third-party software provided with your IDRaman mini on a USB drive.  

Installing Tera Term Software 

► 

Procedure 

1.

 

Find the Tera Term folder on the USB drive provided and copy it to your computer. 

2.

 

Double-click the installation file in the Tera Term folder. 

3.

 

Once the software is installed: 

a.

 

Turn on the IDRaman mini 

b.

 

Connect it to the USB port on the computer using the supplied cable. 

4.

 

Start the Tera Term software. 

5.

 

Select 

Serial

6.

 

Select port that you are using to connect to the IDRaman mini. 

 

7.

 

Click 

OK

Содержание IDRaman mini

Страница 1: ...A 34698 Phone 727 733 2447 Fax 727 733 3962 8 a m 8 p m Mon Thu 8 a m 6 p m Fri EST E mail Info OceanOptics com General sales inquiries Orders OceanOptics com Questions about orders TechSupport OceanO...

Страница 2: ...without written permission from Ocean Optics Inc This manual is sold as part of an order and subject to the condition that it shall not by way of trade or otherwise be lent re sold hired out or otherw...

Страница 3: ...mechanically block the path 4 Never look directly into the laser source or scattering laser light from any reflective surface Never sight down the beam into the source 5 Maintain experimental setup at...

Страница 4: ...nd up to 100 mW of 785nm NIR laser light may be emitted during data acquisition Only personnel trained in laser safety protocols should be allowed to use this instrument The aperture warning label ind...

Страница 5: ...dous when intra beam ocular eye exposure occurs i e when one intentionally or unintentionally looks directly into the beam from within the Nominal Optical Hazard Distance NOHD Never look directly into...

Страница 6: ...ices D 000 40000 010 02 201307 Condition 1 Sample door open Safety interlock defeated or failed No auxiliary lenses present N O H D 10 3 cm 4 06 in Condition 2 Point and Shoot attachment installed N O...

Страница 7: ...nd Operation 5 Overview 5 Controls and Indicators 5 Peak Software Set up 9 Peak Acquisition Software 10 Software Overview 11 Creating Library Files 12 Saving a Library Spectrum 12 Acquiring a Referenc...

Страница 8: ...Table of Contents ii 000 40000 010 02 201307 Appendix A Tera Term Software 25 Installing Tera Term Software 25 Changing Pin Codes 26 Appendix B Specifications 27 Index 29...

Страница 9: ...an access documentation for Ocean Optics products by visiting our website at http www oceanoptics com Select Technical Operating Instructions then choose the appropriate document from the available dr...

Страница 10: ...anty ensures you of the highest level of craftsmanship and reliability for years to come No other manufacturer offers such a solid guarantee of quality and reliability The Ocean Optics 3 Year Warranty...

Страница 11: ...es an internal calibration routine to ensure the most accurate Raman shift data is acquired Measuring most samples in less than 9 seconds the IDRaman provides visual confirmation of results and displa...

Страница 12: ...I is available as a standalone product or packaged with a helpful accessory pack IDR MINI KIT The accessory pack can also be purchased separately IDR MINI ACCY IDR MINI Consists of the handheld Raman...

Страница 13: ...may result in noisy signals or missing the Raman active target completely leading to false negative readings from unidentified samples Increasing the spot size of the laser dilutes the valuable inform...

Страница 14: ...1 Introduction 4 000 40000 010 02 201307...

Страница 15: ...and operating the IDRaman mini Read all instructions and warnings carefully before attempting to install and operate your device IDR MINI Controls and Indicators The IDRaman mini features a user frien...

Страница 16: ...010 02 201307 Screen Description The initial power up screen Enter your 4 digit pin the default is 1234 The system has been activated A vial has been left in the compartment The system has been activ...

Страница 17: ...een activated The door is closed and there is no vial in the sample compartment The system performs an auto calibration The system is ready for a sample Press to begin acquisition The system is ready...

Страница 18: ...a Observe caution as the laser radiation will exit the point and shoot laser attachment This match screen displays the Pearson correlation stored spectrum library green and the sample spectrum red Whe...

Страница 19: ...anual calibration by clearing the sample vial area and pressing this tool button This tool will turn green if the calibration passes and red if it fails Activates Dynamic Raman Scattering DRS The DRS...

Страница 20: ...tartup Menu Wait until the system s red button disappears You are ready to take spectra 9 Install Tera Term open source software from the USB memory stick for later use during library building See App...

Страница 21: ...2 Set up and Operation 000 10000 080 02 0505 11 Software Overview...

Страница 22: ...n again to exit Library mode Saving a Library Spectrum To save the library spectrum use the SAVE feature described in Saving Spectra Save the files in the lib Lib file format After you save your libra...

Страница 23: ...the CCD detector The slide switch at the top Use Reference determines if a reference is used Use Reference Yes causes the reference to be subtracted this is the default Select Use Reference No if you...

Страница 24: ...ssing the average button again NOTE Average will acquire a full set of averaged references before it begins acquiring spectra Peak CleanTM Peak Clean is a beta correction algorithm to produce spectra...

Страница 25: ...quires and displays the number of spectra chosen DRS will produce optimal results with short integration times and statistically most significant with a relatively large number of acquisitions When th...

Страница 26: ...2 Set up and Operation 16 000 40000 010 02 201307 Button Function Save Press this button and then choose the file format to save spectra...

Страница 27: ...d Operation 000 10000 080 02 0505 17 Display Features Graph Palette The Graph Palette brings up a menu to expand spectral regions Scale Palette The scale palette is used to lock or unlock the autoscal...

Страница 28: ...te Resetting the Time and Date Any time the batteries are removed for more than 30 minutes the time and date stamp will reset to 1970 Procedure To reset the time and date stamp 1 From the Tools menu s...

Страница 29: ...vice Spectra Contains time and date stamped files saved using the Save function on the IDRaman mini in an ASCII format which can be opened by any spreadsheet software LibraryTemp Contains the same tim...

Страница 30: ...those files into the Library folder to add more compounds to the library 5 If you saved a spectrum of a compound using the Save function on the IDRaman mini follow these procedures to add the file to...

Страница 31: ...80 02 0505 21 c Copy the file d Paste the file into the Library folder Building a Secure Library Procedure 1 The first time you build a library your folder c users public snrisecurelibrary should cont...

Страница 32: ...d select the Secure Library button This will invoke the Secure Library dialog 4 After you have entered your library folder name and an allowed output file name the dialog will ask for your security ke...

Страница 33: ...u have successfully created your encrypted library compound usr it will appear in the snrisecurelibrary folder It can now be transferred to the IDRaman mini using the USB drive tool It should go in th...

Страница 34: ...2 Set up and Operation 24 000 40000 010 02 201307...

Страница 35: ...e Tera Term folder on the USB drive provided and copy it to your computer 2 Double click the installation file in the Tera Term folder 3 Once the software is installed a Turn on the IDRaman mini b Con...

Страница 36: ...Setup tab 9 Select the Terminal option 10 Select the Local Echo box and click OK You can now see what you are typing Changing Pin Codes Procedure To reset the PIN using Tera Term 1 Type ID Pinset nnn...

Страница 37: ...Battery 2 AA batteries 6 hours w Alkaline 11 hours w Lithium External Power Supply Not applicable replaceable batteries used USB power available Weight 11 75 oz 0 33kg Dimensions 3 6 x 2 80 x 1 5 in 9...

Страница 38: ...B Specifications 28 000 40000 010 02 201307...

Страница 39: ...ocument audience iii purpose iii summary iii Dynamic Raman Scattering DRS 15 F features 1 G graph palette 18 I indicators 5 introduction 1 L library 12 building 19 building a secure 22 M models 2 O ov...