This manual is applicable to both the LightJet 430 and LightJet 430RS printers. All references 
to the LightJet 430 also refer to the LightJet 430RS.  

The LightJet

®

 430 is a wide format digital color printer capable of producing large 

photographic quality images on various paper and film materials from several data formats. The 
photographic media is held stationary during imaging in an internal drum. Media advances are 
required between imaging times. The standard operating mode of the printer is roll to roll. 

Using This Guide 

This Site Preparation Guide describes the physical attributes and site requirements necessary for 
installing and operating the LightJet

® 

430 digital photo printer. The guide is structured as 

follows: 

 

Chapter One describes the contents of the document and some important safety 
information for all users of the printer. 

 

Chapter Two describes the shipping, handling, location and installation requirements for 
the LightJet

®

430, including customer-supplied equipment. 

 

Appendix A

 

is a Pre-installation Site Checklist that will help you ensure that your site is 

prepared for LightJet

® 

430 installation. 

 

Important Safety Information For All Users 

This is a Class 1 laser product meeting laser safety requirements of 21 CFR 1040 and 
EN60825-1 as applicable. Laser devices contained within this equipment are hazardous. All 
procedures necessary to perform user functions are outlined in this document.  Internal lasers 
have the following output characteristics under maximum conditions: 

 

Laser Type 

Wavelength 

(nm) 

Output Power

(mW) 

Beam Divergence 

(mRad) 

Helium Neon (HeNe) Red Laser: 

633 

14 

1.4 

Helium Neon (HeNe) Green Laser: 

543 

1.7 

1.0 

Argon (Ar+) Blue Laser: 

458 

2.5 

1.0 

Table 1-1. LightJet

® 

430 laser specifications 

Содержание LightJet 430

Страница 1: ...Oc LightJet 430 Site Preparation Guide Revision J June 2005 Document 3010045572...

Страница 2: ...Oc Display Graphics Systems 2002 ALL RIGHTS RESERVED...

Страница 3: ...uirements 2 4 Electrical Requirements 2 5 AC Power 2 5 Power Factor Correction 2 6 GFI Circuit Breakers 2 6 AC Distribution Circuit 2 6 Grounding 2 6 Power Cord Specifications 2 7 Power Outlet Specifi...

Страница 4: ...2 2 Figure 2 2 LightJet 430 dimensions 2 3 Figure 2 3 Building access requirements 2 4 Figure 2 4 Darkroom size requirements 2 5 Figure 2 5 Left side connections 2 8 Figure 2 6 Right side connections...

Страница 5: ...ments replaced Gretag with Oc Feb 13 2002 H Added info that manual also covers LightJet 430RS Apr 16 2002 I Added note on page 2 9 about clean dry air being necessary Updated phone numbers for service...

Страница 6: ...o conduct repairs Service visits are paid for by the customer either under a maintenance agreement or by purchase order or prepayment Time and material rates are charged for any service not covered un...

Страница 7: ...tes Of America FCC Canada ICES 003 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This d...

Страница 8: ...r Safety This equipment is a Class 1 laser product which is safe under all operating conditions The following standards were used to evaluate compliance United States of America Center for Devices and...

Страница 9: ...structured as follows Chapter One describes the contents of the document and some important safety information for all users of the printer Chapter Two describes the shipping handling location and ins...

Страница 10: ...SERSTRAHLUNG IM OFFENEM ZUSTAND UND MIT BERBR CKTEN SICHERUNGSSCHALTERN WIRD VON DIESEM GER T LASERSTRAHLUNG EMITTIERT VERMEIDEN SIE DIE BESTRAHLUNG DER AUGEN DURCH DIREKTE ODER GETREUTE LASERSTRAHLUN...

Страница 11: ...the proper equipment available for handling and moving the shipping crate The printer is shipped in a wooden crate with the dimensions shown in Figure 2 1 The loaded crate weighs approximately 970 kg...

Страница 12: ...e or tile floors this should be considered when selecting the installation route and final location The dimensions of the LightJet 430 are shown in Figure 2 2 1 Figure 2 3 illustrates minimum size req...

Страница 13: ...System Requirements 45572 I see copyright disclosure use and duplication information on pg iii 2 3 88 170 cm 224 cm Figure 2 2 LightJet 430 dimensions...

Страница 14: ...ing conditions found in a normal working environment The room size required is illustrated in Figure 2 4 1 The room dimensions specified are minimum requirements and must not be reduced 2 Notes 1 This...

Страница 15: ...area around the machine must be kept clear of obstructions Cables must be managed to prevent tripping We recommend that the host computer reside in a room adjacent to the darkroom This allows host ope...

Страница 16: ...it breakers Use standard thermal circuit breakers where possible 1 For protection of personnel and equipment use an appropriately rated and protected AC circuit to supply power to the LightJet 430 AC...

Страница 17: ...cription IEC 320 Power Cord Set Length 244 cm 8 feet Cordage Rating 3 1 5 mm HAR Oc Reference 40889 Power Outlet Specifications The AC power outlet must be located such that no more than an 8 foot pow...

Страница 18: ...directing the heated air out of the darkroom This will remove 5000 BTU per hour 1440 watts from the machine Use metal or plastic clamps to secure the hose to the machine As shown in Figure 2 5 locate...

Страница 19: ...Volume flow 1 CFM Pressure 70 psi regulated Air supplied to the machine must pass through an air preparation unit that contains the following Air filter 5 0 micron element complete with an auto drain...

Страница 20: ...ecessary to consult a third party to isolate the source of such vibrations It is recommended that the LightJet 430 be installed on a stiff well supported floor a concrete floor is ideal to minimize tr...

Страница 21: ...formation The X Rite 892 is a scanning densitometer and requires the following cables when connecting directly to the host computer telecom to 9 pin DB style null configured adapter p n 881 91 and tel...

Страница 22: ...views of tiles frames in data base on LJ Spooler Storage drive C B B E F Input Frame data nested tiles from local database composed by LightJet Spooler Control Output From local disk to LightJet 430 v...

Страница 23: ...the operating system is SCSI two controllers are required The first is for the operating system hard drive and other peripherals The second is for the imaging hard disk and communication with the Lig...

Страница 24: ...fastest highest quality wide format digital photo printer available Maximum performance requires a properly trained operator Oc trains the operator in the use of the LightJet 430 hardware and the con...

Страница 25: ...100 30 5 m 100 Supported Widths for All Three Media Types 76 cm 30 81 cm 32 102 cm 40 127 cm 50 Table 2 1 Supported media dimensions Oc Display Graphics Systems and or the respective media manufactur...

Страница 26: ...LightJet 430 site preparation guide see copyright disclosure use and duplication information on pg iii 45572 I 2 16 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 27: ...rformed efficiently please review this document carefully and send the completed checklist to us at least three weeks before the scheduled installation date This will allow us enough time to help you...

Страница 28: ...ding Dock Loading Dock adequate to uncrate at customer facility Fork Lift available 2500lb 1200kg Capability Clear path from loading dock to darkroom Darkroom dimensions 403 cm 158 5 335 cm 132 Electr...

Страница 29: ..._____ Processor Monitored and Graphed one per processor setup Densitometer status A reflective transmissive LightJet FE Host Computer with minimum or greater hardware and software components PosterSho...

Страница 30: ...ftware Primary Page Layout Software Vector Primary Image Editing Software Raster Data Transport Method e g Network 100baseT or Jaz Type ___________________ Type ___________________ Type ______________...

Страница 31: ...rmation on pg iii A A 5 Installation Start Date The customer agrees to have an operator available for the installation This will allow the customer to get into production as quickly as possible Signat...

Страница 32: ...see copyright disclosure use and duplication information on pg iii 45572 I A A 6 THIS PAGE INTENTIONALLY LEFT BLANK...

Отзывы: