19
616 01 1019 00
Shielded Wire
If the thermostat wiring will be located near or in parallel with
high voltage wiring, cable TV or Ethernet wiring, then shiel-
ded thermostat wire can be used to reduce or eliminate po-
tential interference. The shield wire should be connected to
the C terminal, or ground, at the indoor unit. The shield wire
should NOT be connected to any terminal at the wall control.
Connecting the shield to ground at both ends can cause cur-
rent loops in the shield, reducing shield effectiveness.
Non-communicating equipment
The Observer® Control, when paired with the
NAXA00101DB daughter board, will operate non-communic-
ating equipment. When the system utilizes the
NAXA00101DB daughter board, the Observer Control oper-
ates as a standard universal thermostat. See Appendix Wir-
ing Diagrams
Mounting
First become familiar with all plastic assembly pieces shown
in Figure 2. The wall control will snap together with the
back-plate. A back-plate is supplied Figure 2
.
Attach
back-plate using only a small hole in the wall allowing a four
wire connection to pass through. Mount the assembly to the
back-plate.
NOTE
: Once Observer Control is secured to wall with the
back-plate assembly (snapped together), care must be taken
not to bend or break the interlocking tabs when removing.
Содержание TSTAT0201CW
Страница 12: ...12 616 01 1019 00 A14558 2 Press under All Days then press EDIT...
Страница 20: ...20 616 01 1019 00 3 90 5 20 0 97 Fig 2 Wall Control Assembly Pieces...
Страница 25: ...25 616 01 1019 00...
Страница 40: ...40 616 01 1019 00 Fan on with W An option to turn the fan on with a call for heating ON OFF default...
Страница 65: ...65 616 01 1019 00 Zones...
Страница 75: ...75 616 01 1019 00 Appendix Wiring Diagrams Note R and C required for single stage communicating equipment...
Страница 76: ...76 616 01 1019 00...
Страница 77: ...77 616 01 1019 00...
Страница 78: ...78 616 01 1019 00...