Communicating Wall Control

With Wi--Fi

R

Capability

Installation Manual

TSTAT0201CW

U.S. Patent No. 7,243,004

U.S. Patent No. 7,775,452

C O M M U N I C A T I N G     S Y S T E M

R

All trademarks are the property of the respective owners.
Wi-Fi

®

is a registered trademark of the Wi-Fi Alliance Corporation.

Содержание TSTAT0201CW

Страница 1: ...FiR Capability Installation Manual TSTAT0201CW U S Patent No 7 243 004 U S Patent No 7 775 452 C O M M U N I C A T I N G S Y S T E M R All trademarks are the property of the respective owners Wi Fi i...

Страница 2: ...ensors 16 Wiring Considerations 17 Shielded Wire 19 Non communicating equipment 19 Mounting 19 Humidifier Connection 21 Bypass Humidifiers 21 Fan Powered Humidifiers 21 Commissioning 22 Communicating...

Страница 3: ...furnaces only 32 Blower RPM Modulating furnaces only 33 Lockout Timer 33 Heat Pump AC Status 33 Stage Heat Cool 33 Defrost 33 Outdoor Coil Temp 33 Last 10 System Faults 33 Lifetime Run History 34 Cycl...

Страница 4: ...l Types 52 Humidity Offset 53 Programming On Off 54 Reset to Factory Defaults 55 Dealer Info 56 Service Reminder 57 Install Service Menus Communicating Equipment 57 Setup Menu 57 English Metric Displa...

Страница 5: ...ypass 68 Airflow Capacity 68 Damper Type 69 Leaving Air Sensor LAS 70 Disable Zoning 70 Damper Timing 71 HRV Heat Recovery Maintenance 71 Daughter Board 72 Operational Information 73 Auto Mode 73 Setp...

Страница 6: ...Read these instructions thoroughly and follow all warnings and cautions included in literature and attached to the unit Consult local building codes and the current edition of the National Electrical...

Страница 7: ...efficiency and com fort They support controlled humidification dehumidification and air quality control Either an Observer communicating or a standard 24VAC controlled outdoor unit may be used When us...

Страница 8: ...et service provider or mobile device carrier service International Comfort Products makes no repre sentations or warranties express or implied including to the extent permitted by applicable law any i...

Страница 9: ...will allow a quick start up of the Observer Control before learning all the details of system operation However for the best possible comfort and operation refer to the Owner s Manual Set Day and Time...

Страница 10: ...ct the appropriate date Un der time you can select the hour minute and am pm then use the and to select the appropriate time You also have the option of selecting between a 12 HR or 24 HR clock format...

Страница 11: ...ays The Observer Control gives you flexibility in how to create a comfort schedule You can choose one schedule for all days create a schedule for your work week and the week end or you can make every...

Страница 12: ...12 616 01 1019 00 A14558 2 Press under All Days then press EDIT...

Страница 13: ...PERIOD then use the or to select the period to change 4 Press START then use the or to change the time the corresponding period starts 5 Press HEAT TO then use the or to change the desired heating te...

Страница 14: ...Setup commissioning operation and troubleshooting of the communicating system are covered only in this installation instruction It is the guide to connecting the system compon ents and commissioning t...

Страница 15: ...guidelines should be followed The Observer Control and Room Sensors SHOULD be mounted Approximately 5 ft 1 5 m from the floor Close to or in a frequently used room preferably on an inside partitioning...

Страница 16: ...The remote sensor can be wired to the terminal block connectors labeled S1 and S2 at the control s back plate The Observer Control will automatically detect the Remote Room Sensor and ig nore its inte...

Страница 17: ...lowing color code be used when wiring each device DX Green Data A DX Yellow Data B C White 24VAC Com R Red 24VAC Hot NOTE TERMINAL MARKINGS FOR EACH COMMUNICAT ING SYSTEM COMPONENT MAY NOT BE IN THE S...

Страница 18: ...length and routing of each wire to reach each wire entry on the connector back plate Strip 1 4 in 6 4 mm of insulation from each wire 8 Match and connect thermostat wires to proper terminals on wall c...

Страница 19: ...e Observer Control when paired with the NAXA00101DB daughter board will operate non communic ating equipment When the system utilizes the NAXA00101DB daughter board the Observer Control oper ates as a...

Страница 20: ...20 616 01 1019 00 3 90 5 20 0 97 Fig 2 Wall Control Assembly Pieces...

Страница 21: ...ation instruc tions for the proper wiring procedure for each particular hu midifier Fan Powered Humidifiers Most fan powered humidifiers produce internal 24VAC in or der to energize upon a switch or c...

Страница 22: ...all Control is first powered up it will display Loading Graphics then Select Function of this Unit Next it will search for equipment beginning with the indoor then the outdoor and remote room sensors...

Страница 23: ...been found the Installer will be asked to select if a humidifier is installed NOTE If the communicating indoor equipment furnace or fan coil cannot be found the wall control will display the op tion t...

Страница 24: ...door and outdoor equipment have been found or entered the following screen will appear allowing the In staller to select HUMIDIFIER INSTALLED Press YES or NO to make the appropriate selection Selectin...

Страница 25: ...25 616 01 1019 00...

Страница 26: ...tion was made press RELEARN to go back When all of the equipment is correct press SAVE Brand Selection After the commissioning of the Observer Control the in staller will be prompted to select the app...

Страница 27: ...ly be issued for the Observ er Communicating Wall Control Updates are usually made to support new HVAC equipment that are added to our prod uct line install these updates as required for the equipment...

Страница 28: ...lease contact your distributor or call the help desk avail able 8 00 AM 5 00 PM ET M F at 877 591 8908 if you need help with Wi Fi set up and connection to the MyOb serverComfort web server See the Ow...

Страница 29: ...e away from the Wi Fi access point or router More information on Wi Fi range extenders may be found at the www MyObserverComfort com website To establish Wi Fi connectivity to the Observer wall contro...

Страница 30: ...menus contain vital information This information enables the Installer or Service person to view a summary of what has been installed etc This information is not covered in the Owner s Manual To enter...

Страница 31: ...l automatically exit after 90 seconds of no activity Equipment Summary Menu This screen shows indoor unit type and model number out door unit type and model number if a communicating out door unit and...

Страница 32: ...s stage of heat that the furnace is currently delivering OFF LOW HIGH capacity modulating furnace only Electric Heat Fan Coil Displays stages of electric heat that the fan coil is currently delivering...

Страница 33: ...outdoor unit coil only available on 2 stage communicating outdoor units F or C default F Last 10 System Faults This screen will show last 10 events that occurred through out the system Each entry has...

Страница 34: ...indoor unit and outdoor unit if communicating have the following histories Cycle Counters Number of heat cool power cycles the unit has performed Run Timers Lifetime hours of operation in heating cool...

Страница 35: ...the number of hours of fan operation after which the replace filter reminder shall appear Off The Replace Filter Reminder function is disabled 800 7200 hours in 800 hour increments after which the re...

Страница 36: ...a change from heat to cool or vice versa will not occur until the current cycle is satisfied and an opposite mode demand has existed for 30 minutes If the set point is changed the 30 minute timer is...

Страница 37: ...wall control the remote room air thermistor or the average of the local and remote sensors Local use the local sensor in the wall control Remote use the remote room sensor Part No SYSTXI IRRS01 and i...

Страница 38: ...38 616 01 1019 00 Reversing Valve For heat pump applications the reversing valve will be active with heating or cooling operation Heat Cool default...

Страница 39: ...00 English Metric Display Displaying temperature in English or Metric Values F all temperatures and setpoints shown in degrees Fahrenheit C all temperatures and setpoints shown in degrees Celsius Def...

Страница 40: ...40 616 01 1019 00 Fan on with W An option to turn the fan on with a call for heating ON OFF default...

Страница 41: ...Lockout When enabled cooling will not be provided when the outside temperature is below 55 F Off Cooling is allowed at all outdoor air temperatures On Cooling not allowed when outdoor air temperature...

Страница 42: ...ry heat will not be used when the outside temperature is above this setting Off The auxiliary heat can turn on whenever sufficient demand exists regardless of outside air temperature 5 55 F Outside ai...

Страница 43: ...h the heat pump will be locked out and only auxiliary heat will be used Off The heating cycle will always start with the heat pump regardless of the outside air temperature 5 55 F Outside air temperat...

Страница 44: ...44 616 01 1019 00 Minimum Cooling Setpoint The minimum cooling setpoint the user is allowed to set on the thermostat 52 F to 90 F 12 C to 32 C Default 52 F 12 C...

Страница 45: ...45 616 01 1019 00 Maximum Heating Setpoint The maximum heating setpoint the user is allowed to set on the thermostat 50 F to 88 F 10 C to 30 C Default 88 F 30 C...

Страница 46: ...re Offset This option allows calibration or deliberate mis calibration of the outdoor temperature This offset is added to the actual temperature values 5 F to 5 F 3 C to 3 C Number of degrees added to...

Страница 47: ...47 616 01 1019 00 Room Air Temperature Offset 5 F to 5 F 3 C to 3 C Number of degrees added to the actual temperature value Default 0...

Страница 48: ...lected number of minutes prior to schedule change in both heating and cooling mode as energy efficiently as possible Off at the programmed time the setpoints shall be changed to the next programmed se...

Страница 49: ...e minimum difference enforced between heating and cool ing desired temperatures This can allow one setting to push the other to maintain this difference 2 to 6 minimum number of degrees between the he...

Страница 50: ...ing or cooling cycles per hour 2 The Y Y2 W and W2 outputs shall be energized at most twice per hour 4 The Y Y2 W and W2 outputs shall be energized at most four times per hour 6 The Y Y2 W and W2 outp...

Страница 51: ...616 01 1019 00 Auto Changeover Timer This feature designates the minimum number of minutes between heating and cooling operation when in auto mode 5 to 30 minutes 5 minute increments Default 30 minut...

Страница 52: ...616 01 1019 00 Time Between Fuel Types The minimum amount of time the Y1 and Y2 output must be energized in heating before turning on the W1 output 10 to 25 minutes 5 minute increments Default 15 minu...

Страница 53: ...s option allows calibration or deliberate mis calibration of the humidity sensor This offset is added to the actual hu midity value The Test Humidifier option allows the Humidifi er to be toggled on a...

Страница 54: ...ing On Off This feature allows the thermostat to turn off the program ming mode and operate as a non programmable thermostat Off operates as a non programmable thermostat On allows program schedule to...

Страница 55: ...1 1019 00 Reset to Factory Defaults This feature allows the installer to return the thermostat to its factory default settings The installer will need to hold the button down for 10 seconds to reset s...

Страница 56: ...en the user selects dealer info after service or maintenance reminders are displayed on the screen NOTE If the dealer inserts their contact information includ ing email address on this screen the user...

Страница 57: ...up Menu This menu has several layers allowing modification of equip ment settings No settings will need to be made at equipment i e DIP switches on a furnace All configuration settings made effective...

Страница 58: ...58 616 01 1019 00 tion of the information that can be found in the INSTALLER SETUP menu English Metric Display F or C default F...

Страница 59: ...ce Fancoil Heating Airflow Selects the airflow of the indoor unit when heating EFFI CIENCY is the airflow used to meet specified ratings COM FORT is a decreased airflow used to increase the output air...

Страница 60: ...settings This selection en ables the full dehumidify and comfort capabilities of the system When COMFORT is not selected the unit will not run reduced airflows for dehumidification EFF 325 fixed airfl...

Страница 61: ...pacity of the furnace De fault value is the furnace air flow for the lowest heat capacity Maximum CFM only appears with modulating furnaces Maximum CFM to run a modulating furnace This will reduce the...

Страница 62: ...62 616 01 1019 00 Low Heat Rise Set to ON if the system contains a bypass humidifier The ON setting will increase the furnace low heat airflow On Off default...

Страница 63: ...00 Defrost Interval Time interval at which defrost cycles can occur on a heat pump 30 minutes 60 minutes 90 minutes 120 minutes default Auto Defrost interval optimized by outdoor control default for c...

Страница 64: ...01 1019 00 Defrost With Furnace Choose whether furnace operates during defrost cycle YES default NO Quiet Shift Turns on Quiet Shift function in 1 stage or 2 stage commu nicating heat pumps OFF defau...

Страница 65: ...65 616 01 1019 00 Zones...

Страница 66: ...mportance factor than bedrooms and smaller areas The Zone weight affects what heating and cooling stages are used to condition the calling zones If only one zone is calling for conditioning and that z...

Страница 67: ...67 616 01 1019 00 Zone Names Allows the installer to assign a name to each zone Zone Airflow Control Zone airflow control...

Страница 68: ...68 616 01 1019 00 Bypass Select bypass amount for zone X Airflow Capacity This setting is used to limit the allowable zone airflow to prevent excessive air noise from being allowed into a zone...

Страница 69: ...s type of damper requires continuous power to remain open or to remain closed depending on the type of damper that is installed A power open spring closed damper should be wired to the Common and Open...

Страница 70: ...60 F 45 F default Disable Zoning Zoning Enabled Zoning system operates normally Zoning Disabled Zoning operation is disabled All dampers are driven to the open position Temperature is controlled by th...

Страница 71: ...Timing Selects the drive time for the dampers Selections are 15 30 45 60 75 105 and 120 seconds Heat Recovery Maintenance Energizes the fan output at the specified speed for HRV applications DISABLED...

Страница 72: ...mmunicating indoor equipment and non communi cating outdoor equipment The daughter board should be used in the following applications S Non communicating indoor unit with non communi cating outdoor un...

Страница 73: ...d 5 to 120 minutes default 30 minutes Setpoint Deadband The minimum difference enforced between heating and cool ing desired temperatures This can allow one setting to push the other to maintain this...

Страница 74: ...ser OFF system becomes non programmable Smart Recovery This feature applies to programmable operation only The control will start recovery 90 minutes prior to schedule change in both heating and cooli...

Страница 75: ...75 616 01 1019 00 Appendix Wiring Diagrams Note R and C required for single stage communicating equipment...

Страница 76: ...76 616 01 1019 00...

Страница 77: ...77 616 01 1019 00...

Страница 78: ...78 616 01 1019 00...

Страница 79: ...ng Indoor Unit with Non Communicating Outdoor NAXA00101DB Green Yellow White Red OAT Sensor Non Communicating Outdoor W2 Y2 C Y R Y2 W2 C R Wall Control OAT DX R C DX Y G W O O G W1 C Y Y2 R W2 G W1 D...

Страница 80: ...6 01 1019 00 All trademarks are the property of the respective owners Wi Fi is a registered trademark of the Wi Fi Alliance Corporation Copyright 2014 International Comfort Products Lewisburg TN 37091...

Отзывы: