background image

   

PAGE

 

8

OBLICA

 

|

 

SPECIFICATIONS

 

AND

 

PRODUCT

 

GUIDE

ACCESS

PANEL

FIRE

6. ACCESS PANEL

Access panels are recommended for all ORTAL fireplaces. They allow efficient and 
comfortable access to the fireplace receiver and valves, which is required for servicing 
purpose. 
Access panels can designed and positionned to minimise their visual impact as long as 
access to the valves and receiver is maintained. The size of the access panel may vary, 
but in all cases must allow the fireplace technician to effectively conduct a services. We 
recommend a minimum size of 200x200mm. 

However, access panels are not the only option for servicing the fireplace operation 
mechanisms. A technician may also service the fireplace controls by going through the 
firebox. This procedure requires removing the glass panel(s), taking out the interior 
media and lifting the grill, burner and bottom side (explosion valve) of the unit. The 
technician would then return all these fireplace components when service is complete. 
The servicing procedure will take longer than through an access panel.

Fireplace installers are advised to consult with their clients, project architects or interior 
designers regarding the advantages and disadvantages of each service option. 

Содержание Ortal 110 RS/LS

Страница 1: ...ORTAL CORNER FIREPLACES SPECIFICATIONS PRODUCT GUIDE...

Страница 2: ...proved DuraVent flue system as specified Consult the relevant authority to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensure that t...

Страница 3: ...3kPA 0 61kPA 0 22kPA 125 205mm 150H RS LS B135 Marked 1200 with 7x1 275mm orifice Marked 1400 with single 3 9mm orifice 55MJ h 1 13kPA 0 61kPA 0 22kPA 125 205mm 170 RS LS B135 Marked 1200 with 7x1 275...

Страница 4: ...400 130H RS LS 1426 527 930 1343 x 549 412 x 549 150 RS LS 1670 484 757 1595 x 400 412 x 400 150H RS LS 1675 527 930 1594 x 549 412 x 549 170 RS LS 1870 484 757 1795 x 400 412 x 400 170H RS LS 1875 52...

Страница 5: ...254 1930 581 953 200 RS LS 254 2164 538 763 200H RS LS 254 2170 581 953 250 RS LS 254 2664 538 763 250H RS LS 254 2670 581 953 The framing structure must be clad externally with non combustible materi...

Страница 6: ...0 581 953 457 250 RS LS 254 2664 538 763 520 250H RS LS 254 2670 581 953 457 OPTION 2 TIMBER STUDS WITH METAL SECTION The frame must be designed to carry the entire weight of the finished wall with no...

Страница 7: ...EXHAUST AND AIR INTAKE HOT AIR FLOW HEAT RELEASE AS REVEAL VENTING Convection air outlet A convection air outlet is required for all Ortal fireplaces This allows for heat building up within the firep...

Страница 8: ...rvices We recommend a minimum size of 200x200mm However access panels are not the only option for servicing the fireplace operation mechanisms A technician may also service the fireplace controls by g...

Страница 9: ...PAGE 9 OBLICA SPECIFICATIONS AND PRODUCT GUIDE 7 TV CLEARANCES 305mm MIN 305mm MIN RECESSED INSTALLATION FLUSH INSTALLATION...

Страница 10: ...AL DECORATIVE ROOM SEALED GAS APPLIANCES HAVE BEEN TESTED AND APPROVED BY AGA IAPMO R T FOR USE WITH NATURAL GAS NG Australian Standard AS5263 0 2016 Decorative Gas Log and Other Fuel Effect Appliance...

Отзывы: