background image

   

PAGE

 

4

OBLICA

 

|

 

SPECIFICATIONS

 

AND

 

PRODUCT

 

GUIDE

3. DIMENSIONS

A

B

C

MODEL 

(all measurements in mm)

A

WIDTH

B

DEPTH

C

HEIGHT

GLASS FRONT 

FRONT

GLASS SIDE 

SIDE

75 RS/LS

856

473

803

786 x 479

411 x 479

110 RS/LS

1251

484

757

1176 x 400

412 x 400

110H RS/LS

1256

527

930

1173 x 549

412 x 549

130 RS/LS

1419

484

757

1346 x 400

412 x 400

130H RS/LS

1426

527

930

1343 x 549

412 x 549

150 RS/LS

1670

484

757

1595 x 400

412 x 400

150H RS/LS

1675

527

930

1594 x 549

412 x 549

170 RS/LS

1870

484

757

1795 x 400

412 x 400

170H RS/LS

1875

527

930

1794 x 549

412 x 549

200 RS/LS

2110

484

757

2036 x 400

412 x 400

200H RS/LS

2116

527

930

2034 x 549

412 x 549

250 RS/LS

2610

484

757

2519 x 400

412 x 400

250H RS/LS

2616

527

930

2534 x 549

412 x 549

Note: Minimum height off of the floor for all front facing Ortal fireplaces is 210mm.  
Appliance legs must not be removed.

Содержание Ortal 110 RS/LS

Страница 1: ...ORTAL CORNER FIREPLACES SPECIFICATIONS PRODUCT GUIDE...

Страница 2: ...proved DuraVent flue system as specified Consult the relevant authority to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensure that t...

Страница 3: ...3kPA 0 61kPA 0 22kPA 125 205mm 150H RS LS B135 Marked 1200 with 7x1 275mm orifice Marked 1400 with single 3 9mm orifice 55MJ h 1 13kPA 0 61kPA 0 22kPA 125 205mm 170 RS LS B135 Marked 1200 with 7x1 275...

Страница 4: ...400 130H RS LS 1426 527 930 1343 x 549 412 x 549 150 RS LS 1670 484 757 1595 x 400 412 x 400 150H RS LS 1675 527 930 1594 x 549 412 x 549 170 RS LS 1870 484 757 1795 x 400 412 x 400 170H RS LS 1875 52...

Страница 5: ...254 1930 581 953 200 RS LS 254 2164 538 763 200H RS LS 254 2170 581 953 250 RS LS 254 2664 538 763 250H RS LS 254 2670 581 953 The framing structure must be clad externally with non combustible materi...

Страница 6: ...0 581 953 457 250 RS LS 254 2664 538 763 520 250H RS LS 254 2670 581 953 457 OPTION 2 TIMBER STUDS WITH METAL SECTION The frame must be designed to carry the entire weight of the finished wall with no...

Страница 7: ...EXHAUST AND AIR INTAKE HOT AIR FLOW HEAT RELEASE AS REVEAL VENTING Convection air outlet A convection air outlet is required for all Ortal fireplaces This allows for heat building up within the firep...

Страница 8: ...rvices We recommend a minimum size of 200x200mm However access panels are not the only option for servicing the fireplace operation mechanisms A technician may also service the fireplace controls by g...

Страница 9: ...PAGE 9 OBLICA SPECIFICATIONS AND PRODUCT GUIDE 7 TV CLEARANCES 305mm MIN 305mm MIN RECESSED INSTALLATION FLUSH INSTALLATION...

Страница 10: ...AL DECORATIVE ROOM SEALED GAS APPLIANCES HAVE BEEN TESTED AND APPROVED BY AGA IAPMO R T FOR USE WITH NATURAL GAS NG Australian Standard AS5263 0 2016 Decorative Gas Log and Other Fuel Effect Appliance...

Отзывы: