background image

   page 6

oblica

 | argos model specifications

operate the argos

modes oF use

3 modes of use: ignition, normal rate and slow combustion.

Warning: 

 ignition position only to be used 

during ignition (30 min max).
the appliance must be attended during the 
whole duration of operation in this position!

                                                 

 

 

ignition

place some crushed paper on the grid (avoid glazed 
paper) and some kindlings. lit the paper, close the  
door of the appliance and fully open the air outlet.  
once the fire is well lit up you can load your appliance.  
it is recommended, during the first hours of operation,  
to make a moderate fire so as to allow a normal 
dilatation of the whole appliance. To ease ignition,  
we advise you to keep a bed of ashes on the grid,  
which will be saved for further use (make sure air  
vents aren’t obstructed too much).

Содержание ARGOS

Страница 1: ...argos model specifications Technical Data 2 Installation 3 Operate the Argos 5 Safety Rules 8 Certification 9...

Страница 2: ...lly Australian Standards Test Results Manufacturer Data Power output 11kW 12kW Efficiency 56 76 Weight 169 Kg Dimensions h1250mm 532mm Flue sections Double skin 175 225mm Roof ceiling penetration Trip...

Страница 3: ...uch heat shields has to be made in accordance with the BCA Building Code of Australia If the nearby surfaces are made of incombustible materials and do not get damaged under heat those clearances may...

Страница 4: ...elow Place bottom of the deflector on the rear stops indicator no 2 on sketch Let the front of the deflector sit on the front stops indicator no 3 on sketch Step 1 Step 2 Step 3 Deflector assembly To...

Страница 5: ...ates from the appliance Ventilate the room to limit nuisance Air Control Use the heat resistant glove provided with the appliance to handle the instruments of control which could be very hot Burning r...

Страница 6: ...Place some crushed paper on the grid avoid glazed paper and some kindlings Lit the paper close the door of the appliance and fully open the air outlet Once the fire is well lit up you can load your ap...

Страница 7: ...trains of intermittence cannot be respected or a reduced power is chosen In this case full power can be achieved over duration of 3 hours and at a reduced rate at low power 10 hours of operation are a...

Страница 8: ...y During operation all the stove s surfaces are hot Be careful of burns Never try to modify the stove The use of fuels that are not recommended or unsuitable for the stove are forbidden including liqu...

Страница 9: ...TITLE Oblica Argos wood heater WORK REQUESTED Assessment of appliance to AS NZS 4012 1999 for determination of Power Output and Efficiency and AS NZS 4013 1999 for Flue Gas Emission using hardwood fu...

Отзывы: