OBID
®
Manual
ID RW01L.AB-A
FEIG ELECTRONIC GmbH
Page 31 of 39
H20801-1e-ID-B.doc
5.1.2. READER_MODE
This byte defines the operating mode of the reader.
Bit:
7
6
5
4
3
2
1
0
Function:
-
-
-
DC-FORMAT
SCAN-IF
-
default
b0
b0
b0
b000
b1
SCAN_IF:
This byte is used to select the interface for scan mode
b0
:
Scan mode over the asynchronous interface
b1
:
Scan mode over the data/clock interface
DC_FORMAT:
This parameter is used to specify data transmission for the data/clock interface.
b000
:
Wiegand Emulation (see
Data format: Hex (binary) 1:1, as stored on the transponder.
b001
:
2.3.2.1. Magnetic card emulation
Data format: Hex (binary) 1:1, as stored on the transponder.
b010
:
2.3.2.1. Magnetic card emulation
Data format: per ISO 7811-2, Track 2 (5 bits)
b011
:
Magnetic card emulation (see:
2.3.2.1. Magnetic card emulation
Data format: per ISO 7811-1, Track 1 (7 bits)