Because of its Ethernet interface according 10BASE-T / 100BASE-TX standard ID MAX50.10-xE is
well suited for easy integration CAT-5 infrastructure. Alternatively either a power over ethernet
(PoE) power supply (according to IEEE802.3af) or an external DC power supply can be used.
ID MAX50.10-xE can be ordered in two different versions
1.
ID MAX50.10-RE
The type ID MAX50.10-RE is version with internal relay which is well suited to protect interior
door with common security requirements.
2.
ID MAX50.10-E
The type ID MAX50.10-E is a version to connect the remote I/O-board (ID CPR.I/O-A) with one
relay output and 2 digital inputs. The remote installation of the relay guarantees a maximum on
security if the relay shall switch e.g. a door opener, because it can placed at the interior of the
building
8.1. System delivery contents
1 x
Bottom part of housing (concealed housing)
1 x
Housing upper part with Reader electronic
1 x
Surface mounting adapter
1 x
Connection board
1 x
Screw Torx 3 x 8 mm, Torx T10 for closing the housing
2 x
Thread cutting screws 3,2 x 15 mm for mounting the surface adapter
2 x
Thread cutting screw 3,2 x 25 mm for wall mounting
1 x
Installation instruction
8.2. Optional Accessories
For ID MAX50.10-E:
ID CPR.I/O-A (Order-No. 3420.000.00):
I/O Extension Board with one relay and two digital inputs.
ID CPR.Ethernet Connect-RJ45: (3859.000.00)
Connection board with RJ45 female jack to be used as an alternative to the LSA
connection board which is included in deliveries content.
For ID MAX50.10-RE:
ID CPR.Ethernet Connect-RJ45: (3859.000.00)
Connection board with RJ45 female jack to be used as an alternative to the LSA
connection board which is included in deliveries content.