9.1.5. Connection of the extension I/O-Board ID CPR.I/O-A (ID CPR50.10-E only)
G
N
D
V
C
C
R
x
D
T
x
D
IN
1
IN
2
1 2 3 4 5 6 7 8 9
X1
Fig. 9: ID CPR.I/O-A
ID CPR.I/O-A
ID CPR50.10-E
Pin
Symbol
X3 Pin
1
GND
Ground
6
GND-D
2
VCC
+5 VDC
5
VCC
3
RxD
Receive Input
4
OUT
4
TxD
Transmit Output
3
IN
5
IN1*
Digital Input 1
-
-
6
IN2*
Digital Input 2
-
7
Relay NO
-
8
Relay COM
9
Relay NC
Table 4 Connection assignment of the I/O Extension Board
*
The digital inputs [IN1] and [IN2] must to be connected to the internal ground, connector
[GND]. Any connection to external voltage might damage the unit!
9.1.5.1. Technical Data ID CPR.I/O-A
Dimensions (W x H x D)
43 mm x 39 mm x 13 mm
(1.69" x 1.54" x 0.51")
Weight
20 g
Protection class
IP 20
Supply Voltage
+ 5 V DC
Temperature range
Operation
Storage
-20 °C bis +70 °C
-40 °C bis +85 °C
Relative air humidity
95 % (non-condensing)
Cable length to ID CPR50.10-E
max. 5 m (twisted paired wire)
Relay
1 x switch over
(contacts capacity: 24 V AC/DC 1,5 A)
Digital inputs
2 x activated against GND only (max. 1 k
)