Oasis R1P Скачать руководство пользователя страница 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Location Requirements

 

 

IM POR TANT: 

 

 

For best  performance,  allow a 2” (5 cm) space  around  the  side  and  the  top.  Do not  put  any objects  on  top  of the  chiller that  could 

obstruct  the  fan.

 

 

 

 

 

 

 

 

 

3

 

 

1. Chiller unit

 

 

2. Blue tubing  included

 

4  

with chiller

 

2

 

3. Faucet  is required

 

(sold separately)

 

 

4. Cold water  supply  line

 

 

9

 

5. White tubing  included

 

with chiller

 

5

 

 

6. Filtration

 

(sold separately)

 

7

 

 

10

 

8  

14.75”

 

(37.46 cm)

 

 

7.  Water supply fitting

 

(sold separately)

 

 

8. Filter inlet

 

 

9. Filter outlet

 

 

6

 

8.72"

 

 

10.

 

 

10 . Quick  connect fitting

 

(22.14 cm) 

(26.16 cm)

 

included  with chiller

 

 

 

 

 

 

 

 

Electrical Requirements

 

 

A 120-volt, 60-Hz, 15- or  20-amp,  grounded electrical supply  is required.  

This  drinking  water  cooler  is  intended  to  be  connected  to  a  ground  fault 

circuit interrupting (GFCI) device to meet UL requirements. 

It is recommended  that  a  separate  circuit  serving  only  your  chiller unit 

be  provided.  Use an  outlet  that  cannot  be  turned  on/off  by a switch.

 

 

Recommended  Ground  Method

 

 

The chiller must  be  grounded. This appliance  is equipped with  a power 

supply  cord  with  a 3 prong  ground  plug.  To minimize possible  shock

 

hazard,  the  cord  must  be  plugged  into  a mating,  3 prong,  ground-type 

outlet,  grounded in accordance  with  all national  and  local codes  and

 

ordinances.  If  a  mating  outlet  is not  available,  it is the  personal 

responsibility  and  obligation  of the  customer  to  have  a properly 

grounded, 3 prong  outlet  installed  by a qualified  electrician.

 

 

 

 

 

 

 

 

4

 

Содержание R1P

Страница 1: ...e refroidissement sous l vier Instructions d installation et guide de soins et entretien Questions sur les caract ristiques prix de vente sugg r op ration rendement pi ces accessoires ou service appel...

Страница 2: ...pen if the instructions are not followed 2 Table of Contents CHILLER SAFETY 2 ASSISTANCE OR SERVICE 3 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 4 Electrical Requirements 4 Wa...

Страница 3: ...y for correct installation It is the responsibility of the installer to comply with installation specifications and with state and local plumbing codes Water connections use easy to connect fittings t...

Страница 4: ...nded electrical supply is required This drinking water cooler is intended to be connected to a ground fault circuit interrupting GFCI device to meet UL requirements It is recommended that a separate c...

Страница 5: ...0 part 10 part 7 part 10 NOTE Tubing must be cut to fit All tubes must be cut squarely with no burrs All tubing connections must be fully seated Tubing must be routed to avoid sharp bends and have eno...

Страница 6: ...ner 6 Set chiller in its normal upright position for storage Draining the Chiller 1 Shut off water supply to chiller 2 Put chiller in position allowing a 2 5 cm space around the side and top 3 Connect...

Страница 7: ...onnection with this product In no event will the Warrantor be liable for indirect special or consequential damages including without limitation economic loss or for any delay in the performance of thi...

Страница 8: ...ues potentiels pouvant causer des blessures ou la mort vous ou d autres Tous les messages de s curit suivent le symbole d alerte et les mots DANGER ou AVERTISSEMENT Ces mots signifient Le non respect...

Страница 9: ...________________________ Num ro de t l phone __________________________ Num ro de mod le ___________________________________________________ Date d achat ______________________________________________...

Страница 10: ...e prise lectrique appropri e n est pas disponible c est la responsabilit et l obligation du consommateur de faire installer par un lectricien qualifi une prise 3 dents connect e terre 3 1 Refroidisseu...

Страница 11: ...le r servoir doit tre connect directement au refroidisseur sans aucun r gulateur de pression Si vous n installez pas un syst me de filtration avec votre refroidisseur ou si votre syst me de filtrage i...

Страница 12: ...du fil lectrique et videz l eau dans un grand contenant 6 Remettez le refroidisseur a position normale pour entreposage Vider le refroidisseur 1 Interrompez l alimentation en eau vers le refroidisseu...

Страница 13: ...ation soit ouverte J V rifiez que la pression d eau vers le refroidisseur soit minimalement de 30 psi 138 kPa L eau a une saveur d sagr able J Si le distributeur n a pas t utilise depuis 3 jours ou pl...

Страница 14: ...u combin avec une autre machine ou appareil L alt ration ou la modification de ce refroidisseur Proselect peut causer des d g ts d eau des chocs lectriques ou des incendies Sauf pour ce qui est ici cr...

Страница 15: ...marque d pos e de D TEFLON est une marque d pos e de E I Dupont 030099 300 REV E 2015 LVD Acquisition All rights reserved Tous droits r serv s Printed in Mexico Imprim au Mexique Oasis Oasis LVD Acqui...

Отзывы: