Oasis PGN8EBF Скачать руководство пользователя страница 22

Section 8: Maintenance and Decommissioning

22

Maintenance

1. Inspection of condenser should be made at 3-month intervals. To remove dirt and lint 

from condenser, disconnect power supply cord, then use small stiff non-wire or vacuum 
cleaner attachment brush. Observance of this procedure will ensure adequate air 
circulation through condenser so operation is efficient and economical.

2. Outside of unit can be wiped clean with mild soap and water mixture. Never use harsh 

chemicals or abrasive cleaners, including any chlorine solutions. Rinse thoroughly with 
clean water, then dry surfaces.

Overload Protection

The compressor motor, where used, is equipped with an automatic reset protector which 
will disconnect the motor from the line in case of an overload.

Lubrication

This unit is equipped with a hermetically sealed compressor and requires no additional 
lubrication.  The fan motor, where used, on this unit seldom needs oiling, but if required, 
a few drops of SAE 10 oil should be used.

To Discontinue use of Water Cooler

1. Close water shut-off valve and disconnect power to the 

CHILLER

.

2. Provide container to catch water to be drained and place under the cold tank drain.

3. Remove the drain plug from the drain tube.

4. Actuate the bottle filler and allow the water to drain into the bucket.  Replace drain plug.

5. Disconnect power to the 

BOTTLE FILLER

.

6. Disconnect the water supply line at the shut-off valve.

Содержание PGN8EBF

Страница 1: ...1 PGN8EBF PGN8FEBF Wall Mounted Refrigerated Bottle Filler INSTALLATION INSTRUCTIONS...

Страница 2: ...t driver What s Included Tools Hardware Required Section 1 Getting Started 2 Drain Elbow x2 Means to cut 1 1 4 drain pipe T15 Torx screwdriver and bit 4 appropriate anchors not supplied T15 Torx Screw...

Страница 3: ...COMMENDED ADULT BARRIER FREE HEIGHT INSTALLATION SHOWN REDUCE HEIGHT BY 3 INCHES FOR INSTALLATIONS USED PRIMARILY BY CHILDREN AGES 12 AND YOUNGER UNIT SHALL ALSO HAVE A MINIMUM CLEAR FLOOR SPACE 30 76...

Страница 4: ...signed to be operated at a water supply line pressure of up to 100 psi 690 kPa A pressure regulator must be installed in front of unit s water inlet if water pressure including any possible pressure s...

Страница 5: ...5 CHILLER INSTALLATION...

Страница 6: ...t with three chosen anchors not provided 3 An in line strainer is furnished in Water Supply tube Connect Water Supply tube to shut off valve NOTE This connection should not be a solder joint or flare...

Страница 7: ...7 BOTTLE FILLER INSTALLATION...

Страница 8: ...PGN8EBF comes partially assembled for shipping Remove the kit from the packaging and separate it into the assemblies and components shown below Tool Needed T15 Torx bit Drip Tray Assembly Filter Supp...

Страница 9: ...bottle filler and cooler frames to center the frame 3 Affix the frame to the wall with at least 4 anchors into any appropriate anchor points through the staggered slotted holes Be careful to ensure th...

Страница 10: ...center bracket and wall frame 5 Attach the filter support bracket with 2x T15 Torx screws to the frame and drip tray support bracket This bracket helps to prevent the filter cartridge from falling in...

Страница 11: ...stem to the installed P trap NOTE Drainpipes will need to be positioned and cut to length as needed Drain Elbows Drainpipes P Trap 7 Assemble PGN8EBF wrapper to the installed frame Rest the alcove on...

Страница 12: ...n 12 8 If the outer edge of the drip tray is not properly aligned loosen the screws mounting the filter support and drip tray bracket to the frame and push forward or back as needed Then retighten the...

Страница 13: ...13 Water Line With Insulation Tubing Provided Solenoid Valve Route the insulated cold water out line up into the bottle filler cabinet and connect it to the solenoid valve located in the alcove FOR U...

Страница 14: ...TANT It is required to keep in line strainer in system for unit to function properly removing strainer can cause damage to solenoid valve and or cartridge system if applicable DO NOT turn the water on...

Страница 15: ...After the frame has been installed not shown insert the insulated water line from the cold tank into the solenoid located at the top of the alcove assembly 9 Cooling Tank Water Outlet Cooling Tank Wat...

Страница 16: ...power cord from side opposite of the condenser fan to ensure it does not become an obstruction Power Brick IEC Connector 10 Turn on water source and check for leaks 11 Ensure nothing is obstructing t...

Страница 17: ...degrees until secured 11 To flush the filter ensure that the condenser fan is free from obstructions and plug in the unit then turn on the water source Check for leaks FOR FILTERED MODEL ONLY Install...

Страница 18: ...be functioning properly install the front cover panel by inserting the top flanch up between the wrapper and center bracket then tipping the panel back to the fountain Secure it with the 2x 8 hex or...

Страница 19: ...Bottle Count 0 5L 1 Bottle Flow Rate 1 2 GPM 20 second maximum dispense time To change the program settings follow these steps For each model top cap will need to be set aside until programming is co...

Страница 20: ...e 2 1 041250 001 Panel Front 3 1 041241 001 Panel Filter 4 1 041238 006 Wrapper 5 2 A020967 1 1 2 Elbow W Nuts 1 1 4 6 4 039043 001 Washer Slip 1 1 2 to 1 1 4 7 1 036010 002 Waste Tube 6 13 8 1 036010...

Страница 21: ...ket ONN Center ITEM QTY P N DESCRIPTION 12 1 041250 001 Panel ONN Front 13 1 035081 010 Panel Side Right STN 430 14 1 031766 201 Condenser 15 1 031767 004 Shroud Fan 16 1 038773 002 Blade Fan 17 1 038...

Страница 22: ...ion The compressor motor where used is equipped with an automatic reset protector which will disconnect the motor from the line in case of an overload Lubrication This unit is equipped with a hermetic...

Страница 23: ...y other machine or device Alteration or modification of this machine may cause serious flooding and or hazardous electrical shock or fire EXCEPT AS SET FORTH HEREIN THE MANUFACTURER MAKES NO OTHER WAR...

Страница 24: ...trademark of LVD Acquisition LLC dba Oasis International 2023 LVD Acquisition LLC 24 222 East Campus View Blvd Columbus OH 43235 614 861 1350 www oasiscoolers com OASIS INTERNATIONAL Wall Mounted Ref...

Отзывы: