4. Safety Instruc
tio
ns
Installa
ti
on, repair or reloca
ti
ons must be done by a fully qu
alifi
ed person and not by the customer. If done
incorrectly it may cause
fi
re, electric shock, water leakage and other hazards.
A circuit breaker must be installed for the unit.
To avoid risk of electrical shock, the unit must have a good power connec
ti
on and earthing.
The unit is equipped with an over-load protec
ti
on system. A
ft
er a previous stoppage, the unit will not start for at
least 3 minutes.
Do not use any means to accelerate the defros
ti
ng processor or to clean other than those
recommended by the manufacturer.
The unit must be stored in a room without any con
ti
nuously opera
ti
ng igni
ti
on sources
(for example: open
fla
mes, an opera
ti
ng gas appliance or an opera
ti
ng electric heater.)
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qua
lifi
ed
persons in order to avoid a hazard.
The appliance shall be installed in accordance with na
ti
onal wiring regula
ti
ons.
Before obtaining access to terminals, all supply circuits must be disconnected.
An all-pole disconnec
ti
on device must be incorporated which as at least 3mm clearances in all poles, a leakage
current that may exceed 10mA, residual current device (RCD) having a rated residual opera
ti
ng current not
exceeding 30mA and disconnec
ti
on must be incorporated in the
fi
xed wiring in accordance with the wiring rules.
The unit should be installed, operated and stored in a room with a
fl
oor area larger than 30m2.
-
The installa
ti
on of pipe-work shall be kept to a minimum 30 m2
-
Spaces where refrigerant pipes shall be compliance with na
ti
onal gas regula
ti
ons.
-
Servicing shall be performed only as recommended by the manufacturer.
-
The appliance shall be stored in a well-ven
tila
ted area where the room size corresponds to the room area as
spec
ifi
ed for opera
ti
on.
-
All working procedure that a
ff
ects safety means shall only be carried by competent persons.
Transport of equipment containing
fl
ammable refrigerants
-
Compliance with the transport regula
ti
ons
-
Marking of equipment using signs
-
Compliance with local regula
ti
ons
-
Disposal of equipment using
fl
ammable refrigerants
-
Compliance with na
ti
onal regula
ti
ons
-
Storage of equipment/appliances
-
The storage of equipment should be in accordance with the manufacturer's instruc
ti
ons. Storage of packed
(unsold) equipment
-
Storage package protec
ti
on should be constructed such that mechanical damage to the equipment inside
the package will not cause a leak of the refrigerant charge.
-
The maximum number of pieces of equipment permi
tt
ed to be stored together will be determined by local
regula
ti
ons.
Use supply wires suitable for 75°C
* Cau
ti
on: Single wall heat exchanger, not suitable for potable water connec
ti
on.
11
11
Содержание I Series
Страница 1: ...oasis i series Inverter Pool Heat Pump Installation Operation Manual oasisheatpumps com...
Страница 2: ......
Страница 3: ...Contents 1 1 1...
Страница 8: ...2 Unit Dimensions Unit mm 545 1000 398 Oasis I9 I12 6...
Страница 9: ...Oasis I17 1046 101 453 615 767 Water inlet 40 Water outlet 40 96 790 490 862 466 1160 Oasis I19 7 1 1...
Страница 10: ...Oasis I25 Oasis I29T 8 Water inlet 40 Water outlet 40 96 790 490 862 466 1160...
Страница 24: ...2 2...