ELECTRICAL CONNECTION
PLEASE NOTE:
Electrical connec
ti
on should only be completed by licenced personnel and in accordance with all
relevant New Zealand and Australian Standards, applicable laws and local legisla
ti
ons.
1. Remove the external cover to the electrical terminal by removing the screws and the terminal cover panel.
2. Feed the electrical cable in through the conduit nipple and a
tt
ach the electric supply wires to the applicable
Ac
ti
ve Neutral and Earth connec
ti
ons located in the electrical terminal.
3. To complete the electrical connec
ti
on, install electrical conduit, UF cable or other suitable means as spec
ifi
ed (as
permi
tt
ed by local electrical authori
ti
es) and connect the cable to a dedicated power supply branch circuit
equipped with the appropriate size circuit breaker, or
ti
me delay fuse protec
ti
on.
INITIAL START UP AND COMMISSIONING
PLEASE NOTE:
The water pump must be running and water circula
ti
ng through the heat pump for the system to
operate.
1. Turn on your water
fil
ter pump and check for water leaks and verify
fl
ow to and from the pool.
2. Turn on the electrical power supply to the Oasis unit.
3. Press the ON/OFF
bu
tt
on of the controller for half a second, the heat pump will start within 60seconds
4. To select the opera
ti
ng mode, press the “M” bu
tt
on to cycle to the sun icon (hea
ti
ng)
5. To set the temperature, press
in the main interface, the current target-temperature will
fla
sh
6. Press
to increase the temperature, or press
to decrease the temperature
7. Once the desired temperature is displayed, allow the screen to
ti
me out to set
8. A
ft
er the system has been running for approximately 5 minutes; check the 2 temperatures displayed on the
screen and review the Temperature D
iff
eren
ti
al (TD). The main temperature displayed is the cold water inlet
temperature, the small temperature display is the heated water outlet.
9. Adjust the water
fl
ow by opening or closing the 3-way valve installed at the cold-water inlet to achieve a target
TD of approximately 2°C (e.g. 22°C inlet water and 24°C outlet water)
10. If there is any interrup
ti
on to water
fl
ow (i.e. when the water pump is turned o
ff
), the unit will automa
ti
cally turn
o
ff
and display an E03 error code - no water
fl
ow. This is normal and the system will restart once water
fl
ow is
reinstated.
INITIAL HEAT UP TIME
Ini
ti
al heat up
ti
mes will vary depending on the size of your pool, environmental condi
ti
ons and the capacity of the
system installed. A
ft
er installa
ti
on please allow the unit and pool pump to run con
ti
nuously un
ti
l the desired pool
water temperature is reached (it may take several days for the pool to ini
ti
ally reach the set temperature).
10
Содержание I Series
Страница 1: ...oasis i series Inverter Pool Heat Pump Installation Operation Manual oasisheatpumps com...
Страница 2: ......
Страница 3: ...Contents 1 1 1...
Страница 8: ...2 Unit Dimensions Unit mm 545 1000 398 Oasis I9 I12 6...
Страница 9: ...Oasis I17 1046 101 453 615 767 Water inlet 40 Water outlet 40 96 790 490 862 466 1160 Oasis I19 7 1 1...
Страница 10: ...Oasis I25 Oasis I29T 8 Water inlet 40 Water outlet 40 96 790 490 862 466 1160...
Страница 24: ...2 2...