2.SPECIFICATION
2.1 Performance data of Swimming Pool Heat Pump Unit
*** REFRIGERANT : R410A
Heating: Outdoor air temp:24
/19
, Inlet water temp:26
Unit
Heating Capacity
Heating Power Input
Running Current
Power Supply
Compressor Quantity
Compressor
Fan Quantity
Fan Power Input
Fan Rotate Speed
Fan Direction
Noise
Water Connection
Water Flow Volume
Water Pressure Drop(max)
Unit Net Dimensions(L/W/H)
Unit Shipping Dimensions(L/W/H)
Net Weight
Shipping Weight
Model
kW
BTU/h
kW
A
W
RPM
dB(A)
3
m /h
kPa
mm
mm
kg
kg
mm
Oasis H13bp
13.8
47000
2.1
10.4
230V
/50Hz
1
rotary
1
120
850
horizontal
54
40
4.5
10
956
372
600
1040
415
615
57
66
Unit
Heating Capacity
Heating Power Input
Running Current
Power Supply
Compressor Quantity
Compressor
Fan Quantity
Fan Power Input
Fan Rotate Speed
Fan Direction
Noise
Water Connection
Water Flow Volume
Water Pressure Drop(max)
Unit Net Dimensions(L/W/H)
Unit Shipping Dimensions(L/W/H)
Net Weight
Shipping Weight
Model
kW
BTU/h
kW
A
W
RPM
dB(A)
3
m /h
kPa
mm
mm
kg
kg
mm
Oasis C17bp
18.2
62000
3.0
13.4
230V
/50Hz
1
rotary
1
150
850
horizontal
56
40
6.0
10
1115
455
868
1220
510
880
87
101
EH9h
9.2
31400
1.5
6.7
230V
/50Hz
1
rotary
1
120
850
horizontal
51
40
3.0
10
956
372
600
1040
415
615
51
60
Oasis H17bp
18.2
62000
3.0
13.4
230V
/50Hz
1
rotary
1
150
850
horizontal
56
40
6.0
10
1115
455
868
1220
510
880
86
100
EH9bp
9.2
31400
1.5
6.7
230V
/50Hz
1
rotary
1
120
850
horizontal
51
40
3.0
10
956
372
600
1040
415
615
51
60
Oasis C13bp
13.8
47000
2.1
10.4
230V
/50Hz
1
rotary
1
120
850
horizontal
54
40
4.5
10
956
372
600
1040
415
615
57
66