7.

 

Snap the plastic sensor connector onto the plastic base in the 
location marked in figure 2.  The clip snaps over the rib on 
the outside of the base so that the terminals in the plastic 
housing are inside the base. 

8.

 

Open the valve again.  Now the controller is ready to sense 
any water.  NOTE:  The water supply line should be 
connected directly to the leak controller so it will shut the water off as close to the water supply valve as possible. 

Maintenance

 

 

Replace all four AA batteries yearly to ensure proper leak protection.  USE 
ONLY “AA” SIZE ALKALINE BATTERIES. 

 

Replace batteries if the alarm has been sounding for an undetermined length of 
time 

 

Replace batteries if the low battery alarm is sounding (2 beeps and 2 LED flashes 
in succession) 

 

Press the manual close button (see figure 3) at the annual battery change to ensure 
the valve functions properly.

 

 

 

1.

 

Make sure water is turned off and line is not under pressure. 

2.

 

Remove door by lifting out drip tray and pressing door latch down forcing the top of the door to lean outward.  The 
rectangular opening under the drip tray reveals door latch. 

3.

 

Set door aside carefully to avoid scratching it. 

4.

 

See figure 4 for plumbing path.  There are three water lines: 

 

WHITE:  for water supply to the filter and/or float valve 

 

BLUE:  exits float valve and 
returns to supply reservoir water 

 

VIOLET/PURPLE (Red may be 
used as an alternate):  for 
product water or reverse 
osmosis brine water 

5.

 

Determine where to mount your 
filters in the filter compartment and 
drill new 1/8” diameter holes if 
needed. 

 

CARBON FILTRATION 

INSTALLATION

 

6.

 

If you wish to connect a second 
point-of-use system such as an ice 
maker, you can use the purple 
(alternatively it will be red) colored 
tube already inserted through the 
column support.  You will need to 
replace the elbow on it with a tee as 
shown in figure 4. 

FILTER INSTALLATION (if applicable) 

Figure 2 

Figure 3 

Содержание Aquabar 2

Страница 1: ...the LCD display 5 Setting the Clock 6 Setting hot and cold temperature 6 Setting Energy Saver mode 6 Setting filter life monitor 7 Setting UV bulb life monitor 7 Hot booster mode 8 Locking the displa...

Страница 2: ...of gallons is programmed through the display panel on the front of the unit which is detailed on page 7 No message will be displayed until the accumulated number of gallons reaches approximately 90 o...

Страница 3: ...y by calling customer service at 614 861 1350 Electrical Power Requirements see data plate on base Tri temp models 115v 60 Hz 4 9A 230v 50 Hz 2 5A Duo temp model 115v 60 Hz 1 2A 230v 50 Hz 0 6A CAUTIO...

Страница 4: ...functions properly 1 Make sure water is turned off and line is not under pressure 2 Remove door by lifting out drip tray and pressing door latch down forcing the top of the door to lean outward The r...

Страница 5: ...are ready to connect it to your water supply NOTE If you have a leak controller installed on the unit the water supply line should be connected directly to it This will shut the water off as close to...

Страница 6: ...LAKE 12 Press or button to set the cold water temperature from OFF to COLD about 50 F to COLDER about 45 F to COLDEST about 40 F NOTE Each time the button is pushed the temperature display advances an...

Страница 7: ...tank Example END TIME 6 00 AM When the ENERGY SAVER mode is activated the cold tank and the hot tank will turn back ON at 6 00 AM and normal energy consumption will resume cooling the cold tank and he...

Страница 8: ...o the cooler To engage the lock press and hold the and buttons at the same time for 3 seconds After 3 seconds you will hear a single beep and the word LOCKED will be displayed above the cup icon Once...

Страница 9: ...the reservoir will not drain out 9 In a clean container prepare a solution of 2 teaspoons 10ml of mild dish soap in 2 gallons 8 liters of clean room temperature water 10 Wash the baffle and lids compl...

Страница 10: ...refully pour the 2 gallon solution into the reservoir 5 Let the sanitizing solutions sit for 5 minutes no more than 10 minutes Wipe down the exposed inner surface of the reservoir using the solution i...

Страница 11: ...e of the metal base before trying to slide it down The front ear has a notch to slide over a raised area in the plastic base see figure 7 TO REMOVE THE FAUCET MANIFOLD The center front panel under the...

Страница 12: ...air is required Follow the sequence of steps listed below to avoid damaging the plastic base in the repair process 1 Drain all water from the unit This will make the unit easier to handle 2 Remove the...

Страница 13: ...heat or cool the thermostat may be broken Call customer service Water cooler is noisy The water cooler is equipped with a refrigeration system It is normal to hear a refrigerator like vibrating sound...

Страница 14: ...ries Low Battery first warning Green Or Red after 3 days beeping max Flashing or Off a 2 flashes On or Off a 2 beeps Dry Examine the sensor hold button until LED light stays solid to stop alarm turn k...

Страница 15: ...e the cost of labor required to disconnect and reconnect plumbing and electrical connections or the labor to remove the refrigeration system from the water cooler will be the responsibility of the use...

Страница 16: ...OASIS INTERNATIONAL 222 E Campus View Blvd Columbus OH 43235 U S A 1 800 64 OASIS 1 800 646 2747 www OasisCoolers com Printed in China 2010 OASIS International 031666 019 rev B...

Страница 17: ...he silicone plug from it as well then place baffle into reservoir 5 Gently place the UV bulb into the hole in the SS lid 6 Thread it in turn clockwise until it is snug You can lift the black float lid...

Страница 18: ...hangs up lift it a little higher or let it drop slightly Panel should come free easily 10 Carefully cut zip tie off of bundled wires inside compressor area Don t cut through wire insulation 11 Insert...

Страница 19: ...through hole at back of shelf into the reservoir area 17 Connect wire harness The 4 pin housings only connect one way UV bulb install in Aquabar 2 Note For POU2LR model plug unit in and make sure comp...

Страница 20: ...installed the black cabinet top will be almost flush with the area around the circuit board Start Fingers OASIS INTERNATIONAL 222 East Campus View Blvd Columbus OH 43235 U S A 1 800 950 3226 www oasis...

Отзывы: