background image

Safety

 

recommendations

DANGER

      

This

 

device

 

must

 

not

 

be

 

used

 

for

 

medical

 

or

 

veterinary

 

purposes

.

     

Do

 

not

 

use

 

this

 

item

 

in

 

explosive

 

atmospheres

.

WARNING

  

Do

 

not

 

subject

 

the

 

insertion

 

tube

 

or

 

other

 

cables

 

to

 

strong

 

pulling

and

 

do

 

not

 

move

 

the

 

display

 

unit

 

around

 

by

 

holding

 

the

 

cables

.

Otherwise

 ,

the

 

insertion

 

tube

 

or

 

cables

 

may

 

be

 

damaged

     

Do

 

not

 

subject

 

the

 

distal

 

end

 

to

 

severe

 

impact

 

or

 

pulling

,

do

 

not

 

expose

 

the

 

angulation

 

section

 

to

 

severe

 

impact

 

or

 

bending

.

Otherwise

,

the

 

precision

 

components

 

that

 

make

up

 

of the

 

distal

 

end

 

and

 

the

 

angulaion

  

section

 

may

 

be

 

damaged

Do

 

not

 

allow

 

any

 

liquids

 

other

 

than

 

water

 ,

saltwater

,

machine

,

or

 

diesel

 

oil

 

come

 

into

contact

 

with

 

the

 

insertion

 

tube

,

Otherwise

 ,

the

 

insertion

 

tube

 

may

 

be

 

damaged

.

    
   

 

     

 

 

  

r

2

Do

 

not

 

allow

 

water

 

come

 

into

 

contact

 

with

 

parts

 

other

 

then

 

insertion

 

tube

 ,

water

 

creates

 

the

 

risk

 

of

 

electric

 

shock

 ,

the

 

parts

 

of

 

the

 

instrument

 

other

 

than

 

insertion

 

tube

 

are

 

not

 

watertight

,

so

 

the

 

instrument

 

should

 

not

 

be

 

used

 

or

 

stored

 

where

 

it

 

is

submerged

 

or

 

wet

.  

Do

 

not

 

use

 

or

 

store

 

the

 

instrument

 

at

 

a

 

temperature

 

higher

 

than

 

60

°

C

 

or

 

lower

 

than

 -

20

°

C

.

Store

 

the

 

instrument

 

in

 

dry

 

and

 

adequately

 

ventilated

 

environment

.

Do

 

not

 

modify

 

or

 

disassemble

 

the

 

unit

.

Содержание 2.8

Страница 1: ...Handheld InspectionScope User s Manual ...

Страница 2: ...that make up of the distal end and the angulaion section may be damaged Do not allow any liquids other than water saltwater machine or diesel oil come into contact with the insertion tube Otherwise the insertion tube may be damaged r 2 Do not allow water come into contact with parts other then insertion tube water creates the risk of electric shock the parts of the instrument other than insertion ...

Страница 3: ...17 18 01 Display Unit 02 Charge Indicator 03 MENU 04 Upward Key 05 Downward Key 06 OK Key 07 Play Back 08 Video Key 09 Power On Off 10 Brightness 11 Snapshot 12 Cable Plug 13 Lock nut 14 Tightening Knob 15 Control Wheel 16 2 Way articulation Unit 17 Control Stick 18 4 Way Articulation Unit ...

Страница 4: ...nd articulation unit Be sure of alignment of the Key Slot as Fig2 then crew in securely Fig3 4 1 Inserting SD card SD should be inserted as Fig1 If SD card can t be plugged in smoothly please check orientation Fig1 Fig2 CAUTION CAUTION ...

Страница 5: ...damage may be induced to instrument keep the insertion tube as straight as possible to get best operations The display and articulation unit can be connected by soft cable in between P s The soft cable is a standard accessary which can be find in carry case Fig5 3 Check the display rotatable to left and right around 160 respectively Fig4 5 Fig6 CAUTION NOTE ...

Страница 6: ...ious next function or option To display or pause Confirm selection or option Enter to Menu mode To lock or delete files Return to the preview mode Snapshot To start stop video recording Zoom x2 x4 x8 4 3ratio Image rotation Enter playback mode Return to preview mode Choose camera or maintenance settings 6 Freeze image Zoom x2 x4 x8 4 3ratio only apply to 3 9 5 5 and HD 8 0mm cameras 5 Press power ...

Страница 7: ...k Normal B W Under the Effect selection You can choose the image with color or without color VGA 3 9 VGA5 5 3 9 and HD correspond to camera diameter 5 5mm 3 9mm and 8mm respectively Under the preview mode Press MENU button to display options as follows Camera Hd HD Effect Nor Date Stamp Date OK MENU Enter Back Menu ...

Страница 8: ...year month day or hour minute second and press for number increasing or decreasing OK MENU Enter Back 01 01 2014 00 00 DD MM YYYY Date Time Hd Language TV Out OK MENU Enter Back Power Save Format OK MENU Enter Back Off Date Date Time Under Date Stamp selection Date stamp can be added to recording files or not ...

Страница 9: ...AL 3Min Hd Enter Back 5Min 10Min Disable Setup time for auto power off Format or Reset all Choose Yes to format storage media SD card or return to original settings MENU MENU OK OK Tvout Setup English Hd 简体中文 OK MENU Enter Back Deutsch Français Español Language Setup 7 languages optional 5V DC Rese t TV OUT Fig7 ...

Страница 10: ...otect from being deleted Lock Hd Enter Back Delete MENU OK Lock Unlock one Hd Lock All Unlock All Choose lock you can lock or unlock one or all files Lock Enter Back MENU OK Delete Lock Enter Back MENU OK Delete All ONE Choose Delete to delete one or all files 10 No Hd Enter Back Yes MENU OK Enter Back MENU OK Delete Lock ...

Страница 11: ...ully charged battery can continuously works up to 8 hours 1 Rechargeable battery 2 Cleaning components Cleaning distal end Cleaning insertion tube Wipe thoroughly with a piece of gauze or other material moistened with neutral detergent next clean by gauze moistened with clear water and then wipe the insertion tube dry off all moisture Clear the insertion tube immediately after withdrawing the inse...

Страница 12: ...lay unit Q Unable to take photo or record video A SD card absent wrongly inserted full or faulty Q Shut down A When all functions freeze or fail insert an insulated needle into the hole on the side of the main unit the system will restart automatically Cleaning unit body Wipe with soft cloth dampened with clean water and wipe with clear and dry cloth Store the instrument under normalroom temperatu...

Страница 13: ...of construction Camera and Optical system Model No 2 8 3 9 3 9S 5 5 5 5S 8 0 8 5 8 5IR Diameter 2 8mm 3 9mm 3 9mm 5 5mm 5 5mm 8 0mm 8 5mm Rigid portion 10mm 18mm TBD 23mm TBD 28mm 30mm Housing Steel Alloy Copper Alloy Field of view 80 70 55 Direction of view Forward 90 Forward 90 Depth of view 5 50 mm 4 40 mm 8 100 mm 12 200 mm Forward 5 80 mm 4 40 mm 8 100 mm 12 200 mm 5 80 mm 15 200 mm 35mm infi...

Отзывы: