- GB -
15
Start-up
This unit supports the DMX protocol extension RDM.
•
Start-up and operation are only possible with a DMX-RDM controller.
•
The DMX / RDM protocol is used for signal transmission and control.
Addressing via DMX
DMX (Digital Multiplex) is a standardised digital transmission protocol used in stage and event equipment as well as in
many Oase components.
The DMX channel and the mode can be changed by means of a DMX controller (WECS made by OASE). Read the
corresponding operating instructions
Description Value
Serial No. (SN)
Enter the unit serial number. The serial number is indicated on
the type plate
d
.
Product ID
50
Version No.
1
DMX Channel
Define the DMX channel. The factory-set channel is indicated on
the type plate
c
.
Configuration mode
1 = Define the first DMX channel (starting address)
−
In the standard setting with four DMX channels, the three
following DMX channels are automatically allocated once the
starting address has been defined.
123456789
DM
X
012
01234
12
SN: 123456789
: 24VDC
10,5A max.
4m
Underwater Switch
24 V DC/DMX/02
IP68
max. 35°C
SN:
30
652D/I07
56411
PRI
SEC
P
max
: 24VDC
4x2,5A max.
: 4x60W
OASE
GmbH
Tecklenburger Str. 161, 48477 Hörstel, Germany
Addressing via DMX-RDM
RDM (Remote Device Management) is a new, open and bi-directional protocol standard for DMX-controlled devices.
The permanently transmitted DMX data flow briefly pauses (several milliseconds), and an RDM data package (messa-
ge) is sent directly to a subscriber. The subscriber evaluates the information in the data package and sends an answer
(semi-duplex) on the same line. Targeted polling to a subscriber via its UID (Unique ID) prevents several subscribers
from answering simultaneously.
The protocol makes it possible to receive status information about a unit or to change configurations on a unit. Chan-
ging the configuration means, e.g. changing the DMX address. The prerequisite for this function is a RDM-compatible
controller. Read the corresponding operating instructions
All unit outputs can be accessed individually and simultaneously. Two different operating modes can be selected. The
operating mode can only be configured by means of the Personality ID via RDM.
Personality ID
(Operating mode)
Description of operating mode
RDM display text
Number of DMX chan-
nels
DMX range
starting address
1
(Standard)
A DMX address controls a switch
subject to the DMX value range
Multi Channel Mode
4
1 … 509
2
A DMX address controls all switches
subject to the DMX value range
Single Channel Mode
1
1 … 512
30539-10-13_GA_Underwater Switch15 15
29.10.2013 10:16:30
Содержание Underwater Switch 24V DC/DMX/02
Страница 2: ...2 A UWR0001 B UWR0004 30539 10 13_GA_Underwater Switch2 2 29 10 2013 10 16 30...
Страница 3: ...3 C D UWR0002 UWR0003 E PLX0004 30539 10 13_GA_Underwater Switch3 3 29 10 2013 10 16 30...
Страница 37: ...37 UWR0006 30539 10 13_GA_Underwater Switch37 37 29 10 2013 10 16 31...
Страница 38: ...30539 10 13_GA_Underwater Switch38 38 29 10 2013 10 16 31...
Страница 39: ...30539 10 13_GA_Underwater Switch39 39 29 10 2013 10 16 31...