26
- GB -
8
Maintenance and cleaning
The filter system is self-cleaning. Dead biomass drops to the bottom and has to be removed. To do this,
open the DN 75 dirt outlet for approx. 10 seconds.
►
The entire filter system only needs to be taken out of operation for cleaning and maintenance if it is
extremely soiled.
►
Do not use any chemical cleaning agents as they would kill the filter bacteria.
9.
How to proceed:
1. Switch off all filter pumps.
2. Switch off all other electrical units of the filter system (e.g. UVC clarifying unit).
3. Only applies to gravity fed systems: Close the slide valves (supply and return) of the filters
connected in series to prevent further water flow.
4. Open the slide valve for the DN 75 dirt outlet at the bottom of the container and dispose of the soiled
water in a permissible way.
5. Carry out cleaning measures.
−
Rinse the Hel-X biomedia in the container with running water.
6. Close the slide valve (dirt outlet).
7. Start up the filter system again (
→
Start-up).
8.1
Replace the aerator rod
8.
How to proceed:
I
1. Remove approx. 2/3 of the Hel-X biomedia and keep moist. After completing the maintenance
measures, return the Hel-X biomedia to the container.
2. Pull the aerator rod out of the clamping holder at the bottom of the container.
3. Disconnect the hose from the aerator rod and fit it onto the new aerator rod.
4. Press the new aerator rod into the clamping holder.
9 Storage/Over-wintering
The unit is protected from frost:
The unit can be operated as long as the water temperature does not go below +4 °C.
The unit is not protected from frost:
Take the unit out of operation at water temperatures below +8° C or, at the latest, when freezing
temperatures are to be expected.
►
Drain the unit as far as possible, clean thoroughly and check for damage.
►
Empty all hoses, pipes and connections as far as possible.
►
Leave the slide valves open.
►
Cover the filter container to prevent the penetration of rain water.
►
Protect pipes and slide valves that are in contact with water from frost.
10 Disposal
Support us in our endeavour to keep our environment intact, and adhere to the following disposal
information!
Dispose of the unit in accordance with the national legal regulations.
18172-07-13_GA_ProfiClear Premiu26 26
25.07.2013 12:58:55
Содержание ProfiClear Premium
Страница 1: ...ProfiClear Premium Moving Bed Modul 18172 02 H 18172 GA_Moving_Bed_Modul_A5_end 07 02 12 14 19 Seite 2...
Страница 2: ...2 A ProfiClear0015 B ProfiClea0006 18172 07 13_GA_ProfiClear Premiu2 2 25 07 2013 12 58 52...
Страница 3: ...3 C ProfiClear0008 D ProfiClearr007 18172 07 13_GA_ProfiClear Premiu3 3 25 07 2013 12 58 53...
Страница 5: ...5 H ProfiClear0039 I ProfiClear0045 18172 07 13_GA_ProfiClear Premiu5 5 25 07 2013 12 58 54...
Страница 127: ...127 ProfiClear 0054 18172 07 13_GA_ProfiClear Premiu127 127 25 07 2013 12 58 58...
Страница 128: ...128 ProfiClear0055 18172 07 13_GA_ProfiClear Premiu128 128 25 07 2013 12 58 59...
Страница 129: ...129 Pro ProfiClear0056 18172 07 13_GA_ProfiClear Premiu129 129 25 07 2013 12 58 59...
Страница 130: ...18172 07 13_GA_ProfiClear Premiu130 130 25 07 2013 12 58 59...
Страница 131: ...18172 07 13_GA_ProfiClear Premiu131 131 25 07 2013 12 58 59...
Страница 132: ...18172 07 13 18172 07 13_GA_ProfiClear Premiu132 132 25 07 2013 12 58 59...