- EN -
61
7.3
Operating modes
Description
Information
Automatic mode:
−
Operating mode for normal operation.
−
The display indicates the water temperature as standard.
−
A cleaning cycle is automatically started if the level detection device
signals an excessive deviation in the water level.
−
The level exceeds a certain water level.
−
After 20 automatic cleaning cycles, a cleaning cycle with extended
cleaning time is performed.
Time-dependent operation
−
In addition to the automatic cleaning cycle (dependent upon the water
level in the drum filter), a time-dependent cleaning cycle can be
performed.
: Time-dependent cleaning "Interval")
−
The duration of the cleaning cycle corresponds to the time set in the
cleaning time "Cleaning" menu.
(→
7.4
Manual cleaning
How to proceed
Information
Press for
3 s
−
LED (6) is lit
−
The display indicates
CL
−
To cancel the process: Press the button again
−
The drum motor is stopped for safety reasons if the filter cover is lifted.
The rinsing pump can still be manually started to check the function of
the nozzles.
−
Each active cleaning cycle (automatic, time-dependent or manual) can
be stopped by pressing the button.
7.5
Settings in the menus
N O T E
Settings can only be made in the menus when the control system is switched on.
(→
7.5.1
CL
: Cleaning time "Cleaning"
Setting the cleaning time changes the duration of the cleaning cycle. Extend the cleaning time if the dirt is
not completely carried away by the water, for example if the drain pipes are very long or have lots of
bends, or there is a particularly large amount of sticky dirt (e.g. during spawning).
Please take into consideration that an extended cleaning time leads to increased water consumption. The
default setting of 10 s is normally sufficient (corresponds to approx. a
7
/
8
drum rotation).
Proceed as follows
Information
1.
Press
several times until
Cl
appears in
the display.
−
To cancel and exit the menu: Either wait for 10 s or press
or
.
2. Press
for 5 s until the time is indicated in
the display.
−
To cancel and exit the menu: Either wait for 5 s or press
or
.
3. Press
several times to change the
value.
−
To change the value quickly: Hold down
the button
−
Settable range: 10 – 30 s
−
Increment: 1 s
−
The number can only be changed upwards. Once the value 30 is
reached, the display returns to 10.
−
Saving the set value: Wait for 5 s until the menu is automatically exited.
−
Cancel without saving and exit the menu:
or press
.
Содержание ProfiClear Premium TF-L Pump Fed EGC
Страница 2: ... 2 A ProfiClear0023 ProfiClear0022 ...
Страница 3: ... 3 C ProfiClear0020 D ProfiClear0021 ...
Страница 4: ... 4 E ProfiClear0036 F G ProfiClear0033 ProfiClear0032 H ProfiClear0034 ...
Страница 5: ... 5 I ProfiClear0037 J K ...
Страница 6: ... 6 ProfiClear0060 ProfiClear0061 L ProfiClear0039 ...
Страница 7: ... 7 M ProfiClear0040 ...
Страница 8: ... 8 N ProfiClear0047 O ProfiClear0109 P FMR0031 Q EGC0003 ...
Страница 9: ... 9 R S ProfiClear0044 ProfiClear0043 T ProfiClear0110 U ProfiClear0035 ...
Страница 10: ... 10 V ProfiClear0041 W ProfiClear0042 ...
Страница 11: ... 11 X ProfiClear0050 Y Z ProfiClear0046 ProfiClear0057 ...
Страница 386: ...47626 01 17 ...