9
- GB -
Never operate the unit if the cable or housing are defective! Disconnect the power!
Do not carry or pull the unit by the connection cable.
Only use the unit with the attendant safety transformer contained in our scope of
delivery. Never open the unit housing or its attendant components, unless this is
explicitly mentioned in the operating instructions. Always disconnect the power
supply of all units located in water and of this unit prior to performing work on the
unit! For your own safety, consult a qualified electrician if you have questions or
encounter problems!
Installation
Attention!
Sensitive electrical components.
Possible consequence:
The unit will be destroyed.
Protective measure:
Do not connect the unit to a dimmable power supply.
Important
: Keep a safety distance between transformer and water (A).
−
Drill through the spring stone (B).
−
Only for Lunaled 9: Adapt the diameter of the hose connector (C).
−
Open hose connector (D).
−
Lead connection cable (1) through the hose (2) up to the cable outlet in the
hose connector (E), then connect hose (2).
−
Insert the light ring into the spring stone hole from above (E).
−
Insert seal (3) and close hose connector (4).
−
Connect hose (5) to hose connector and pump.
−
At the transformer, secure the connection cable using the union nut (F).
Start-up
Switching on
: Switch on pump. Connect transformer to socket.
Switching off
: Switch off pump. Disconnect transformer from socket.
Regulate bubbling intensity:
Turn stainless steel cap of the light ring (H) or
regulate connected pump.
Содержание Lunaled 6s
Страница 1: ...Lunaled 6s Lunaled 9s 11271 OASE GAW_Lunaled_A6_end 12 08 2009 17 27 Uhr Seite 2 ...
Страница 2: ...2 ...
Страница 3: ...3 ...
Страница 4: ...4 ...
Страница 30: ...75 ...
Страница 31: ...11271 02 14 ...