Cleaning the quartz glass / Replacing the UVC lamp

Attention! Ultra-violet radiation

.

Possible consequences: 

Eye or skin injury from burns

Protective measures:

•  Never operate the UVC lamp outside its housing.

•  Never operate the UVC lamp in a housing that is defective

Danger: 

Ultraviolet radiation.

Do not expose eyes to lamp rays.

Disconnect power before servicing or replacing lamp.

Replace lamp only with lamp rated 9 watts:

Warning: 

To reduce the risk of electric shock - Connect only to a circuit that is protected by a ground-fault circuit 

interrupter (GFCI)

For indoor and outdoor household use 

Attention! 

Breakable glass

Possible consequences: 

Injury to your hands caused by cuts

Protective measures:

 Handle the quartz glass and UVC lamp with care.

Note!

For safety reasons the UVC lamp can only be switched on when the unit head has been correctly fitted into the casing.

Opening the UCV clarifying unit 

1.

   Remove the cover from the UVC clarifying unit.

○ 

Turn the UVC clarifying unit counter-clockwise up 

against the stop (bayonet closure), then carefully 

pull out of the filter cover including the O ring.

2.

   Loosen the self-tapping screw until the the screw tip 

is sunk in the housing of the clamping screw.

3.

   Unscrew the clamping screw counter-clockwise.

4.

   Remove the quartz glass including the O ring towards 

the front with a slight turning movement.

○ 

Check the quartz glass and the O ring for damage 

and replace, if necessary.

○ 

Clean the quartz glass outer face with a moist 

cloth.

!

!

Содержание BioPress UVC 1000

Страница 1: ...BioPress UVC 1000 1600 2400 Operating instructions Notice d emploi Instrucciones de uso...

Страница 2: ...e with the purchase of this product BioPress UVC 1000 1600 2400 Prior to operating the unit please read the instructions of use carefully and fully familiarise yourself with the unit Ensure that all w...

Страница 3: ...aken Important information for trouble free operation Intended use BioPress UVC 1000 1600 2400 referred to in the following as unit may only be used as specified in the following For operation with cl...

Страница 4: ...the appliance is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified technician Install the unit so that it...

Страница 5: ...unintentional switching on Attention Never operate the unit with a water pressure of more than 2 9 psi 0 2 bar Important Switch the pump on first then the UVC clarifying unit Do not operate the unit...

Страница 6: ...or dirty water from the water outlet returns to the garden pond Carry out quick cleaning first Should this prove insufficient clean the entire unit A blocked filter could lead to leakages Never use c...

Страница 7: ...g by undoing the nut from the pulling rod To remove the nut hold the pulling rod using combination pliers Note Do not pull the pulling rod out of the cover 5 Pull off the foam filters 6 Clean under ru...

Страница 8: ...equences Injury to your hands caused by cuts Protective measures Handle the quartz glass and UVC lamp with care Note For safety reasons the UVC lamp can only be switched on when the unit head has been...

Страница 9: ...nd replace the UVC lamp Assembly of the UVC clarifying unit 6 Insert the quartz glass including the O ring against the stop in the unit head Press the O ring into the gap between unit head and quartz...

Страница 10: ...municipal authority Issue Cause Solution The unit performance is not satisfactory Unit has been in operation only for a short time The complete biological cleaning effect is only achieved after sever...

Отзывы: