8
Clean pump
How to proceed:
F
1. Screw off the stepped hose adapter.
2. Remove screws.
– The screws are used as transport protection and not required for operation.
3. Actuate the engagement hook and fold up the strainer top casing.
4. Remove pump.
5. Remove screws.
6. Remove the pump housing including its holding ring, sealing and impeller unit.
– Clean all components under running water using a soft brush, replace damage parts.
7. Reassemble the unit in the reverse order.
– Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed
when closing the filter housing.
Wear parts
The impeller unit is a wearing part and does not fall under the warranty.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the regu-
lations.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
23795-11-14_GA_AquaMax Eco Class8 8
19.11.2014 11:10:02
Содержание AquaMax Eco Classic 3600
Страница 2: ...2 A AMX0001 B AMX0002 C AMX0003 D AMX0004 23795 11 14_GA_AquaMax Eco Class2 2 19 11 2014 11 10 01...
Страница 3: ...3 E AMX0005 23795 11 14_GA_AquaMax Eco Class3 3 19 11 2014 11 10 01...
Страница 4: ...4 F AMX0006 23795 11 14_GA_AquaMax Eco Class4 4 19 11 2014 11 10 02...
Страница 18: ...18 AMX0007 23795 11 14_GA_AquaMax Eco Class18 18 19 11 2014 11 10 02...
Страница 19: ...23795 11 14_GA_AquaMax Eco Class19 19 19 11 2014 11 10 03...