Installation - Aquarius Universal 180 / 370

Important:

● The unit can be placed within the pond (submerged) or outside of the pond (dry)
●  Do not lift the pump by its power cord. 
●  Install the unit so that it is not exposed to direct sun radiation (max. 104 ºF - 40 ºC). 

Submerged installation

!

Attention! Risk of damage

.

Ensure that the unit does not take in air or runs dry. 

1.  

Align the intake of the suction unit 

 

 Lateral Suction Intake: Allows for maximum flow where 

the the deposits from the bottom of the resivoir are not 

taken into unit.

  

Bottom Suction Intake:  when the suction intake is 

rotated downwards suction is possible up to 0.2 in. (5 

mm). Only operate the unit with the filter housing on 

when intake is rotated downwards. 

●  

Only operate the unit with the filter housing.

1.

●  

For maximum water flow, it is recommended that the 

largest tubing size for your pump is used.

○  If needed, cut the adapter using a hacksaw; 

consult packaging for tubing size. 

2. 

 Screw the adapter onto the return. Attach tubing.

3. 

 Place the unit horizontally with its feet downward

Dry installation

!

Attention! Risk of damage

.

Ensure that the unit does not take in air or runs dry. 

1.  

Align the intake of the suction unit upward.

 

 Operate the unit without filter housing.

●   

For maximum water flow, it is recommended 

that the largest tubing size for your pump is 

used.

○  If needed, cut the adapters using a 

hacksaw; consult packaging for tubing 

size. 

2. 

 Screw the adapters onto the intake and return. 

Attach tubing.

3. 

 Place the unit horizontally with its feet downward

●  

To prevent air from being taken in, ensure that 

unit and supply hose are always below the 

water level.

2.

3.

1.

2.

3.

Start-up

Attention! Dangerous electrical voltage

.

Possible consequences: 

Death or serious injuries.

Protective measures: 

•  Prior to reaching into the water, disconnect the power supply to all units used in the water.

•  Disconnect the power plug prior to carrying out work on the unit.

Attention! The pump must never run dry. 

Possible consequence:

 The pump will be destroyed. 

Protective measure:

 Check the water level at regular intervals. Always place the unit below water level.

1.   

Set the flow at the flow control 

Important:

●   

The unit switches on automatically when power 

connection is established.

2.   Switching on: 

Connect power plug to the socket.

●   

Switching off: 

Disconnect the power plug.

!

!

Attention! Risk of accident

.

The installed temperature monitor automatically turns the pump off, if it is overloaded. The pump automatically 

switches on again once the motor has cooled down. 

Maintenance and cleaning

Attention! Dangerous electrical voltage

.

Possible consequences: 

Death or serious injuries.

Protective measures:

• Before reaching into the water, disconnect all units located in the water from the mains. 

• Disconnect the unit from the mains before performing any work on the unit. 

• Secure the unit to prevent unintentional switching on. 

Installation - Aquarius Universal 80

Important:

● The unit can be only be placed within the fountain or pond (submerged)
●  Do not lift the pump by its power cord. 
●  Install the unit so that it is not exposed to direct sun radiation (max. 104 ºF - 40 ºC). 

!

Attention! Risk of damage

.

Ensure that the unit does not take in air or runs dry. 

●  

For maximum water flow, it is recommended that the largest tubing size for your pump is used.

1. 

 Attach the tubing onto the adapter.

2. 

 Place the unit horizontally with its feet downward.

Aquarius Universal 80

Aquarius Universal 180 / 370

1.

2.

Содержание 57616

Страница 1: ...Aquarius Universal 80 180 370 Operating instructions Notice d emploi Instrucciones de uso...

Страница 2: ...juries if the appropriate measures are not taken Risk of personal injury caused by a general source of danger This symbol indicates an imminent danger which can lead to death or severe injuries if the...

Страница 3: ...rizontally with its feet downward To prevent air from being taken in ensure that unit and supply hose are always below the water level 2 3 1 2 3 Start up Attention Dangerous electrical voltage Possibl...

Страница 4: ...at de votre Aquarius Universal constitue un excellent choix Avant d utiliser la pompe lisez les instructions attentivement et familiarisez vous parfaitement avec l appareil Assurez vous que tout trava...

Страница 5: ...our les personnes en raison d un danger d ordre g n ral Ce pictogramme indique un danger imminent pouvant entra ner la mort ou des blessures graves si les mesures appropri es ne sont pas prises Rensei...

Страница 6: ...qu une baisse de performance est d tect e Nettoyez l unit avec de l eau chaude l aide d une brosse douce N utilisez jamais de produits de nettoyage agressifs ou de solutions chimiques Ceux ci pourraie...

Страница 7: ...sin circulaci n de agua No emplee el equipo para fines industriales No emplee el equipo en combinaci n con productos qu micos alimentos y sustancias f cilmente inflamables o explosivas No conectar a...

Страница 8: ...s en la entrada y el retorno Coloque el tubo 3 Coloque la unidad horizontalmente con los pies hacia abajo Para evitar que entre aire aseg rese de que la unidad y la manguera de suministro est n siempr...

Страница 9: ...227 AC 120 V 60Hz 4 W 80 GPH 300 LPH 1 5 ft 0 45 m 3 3 ft 1 m 39 95 F 4 35 C 6 ft 2 m 0 62 lbs 0 3 kg 2 x 2 x 2 in 50 8 x 50 8 x 50 8 mm 180 37228 8 W 180 GPH 680 LPH 4 9 ft 1 5 m 16 ft 5 m 2 56 lbs 1...

Страница 10: ...Pos Aquarius Universal 80 1 20331 Pos Aquarius Universal 180 370 1 23641 23641 2 20333 20354 3 26187 26187 4 26191 26191...

Страница 11: ...OASE North America INC www oase livingwater com 19651 02 18...

Отзывы: