1.

   Lay the outlet pipe for the water outlet into the pond and 

the hose for the sludge drain into the sewage system or 

flower bed with a sufficient gravity (i.e. slightly downhill).

2.

   Place the unit at a flood protected position at a distance 

from the pond edge of at least 6.6 ft (2 m) on a firm and 

level ground.

○ Ensure unrestricted access to the cover to be able to

carry out work on the unit.

3.

   To avoid pressure loss, use hose connections which are as 

short as possible and have a maximum internal diameter; 

avoid bends and lay well protected.

○ Saw off the open stepped hose nozzle at the

corresponding mark.

    

Push or turn the hose for the water inlet onto the open stepped 

hose nozzle and secure with a hose clip.

    

Place a flat sealing ring on the thread of the stepped hose 

nozzle, push the thread of the stepped hose nozzle through the 

water inlet, insert an O ring on the thread from inside, screw the 

inlet nozzle on the stepped hose nozzle from inside ensuring that 

the opening points downward.

    

Close the second water inlet with the closed hose nozzle (except 

when fitting an OASE UVC pre-clearing unit, e.g. Bitron).

    

Lay the hose so that it cannot be stepped on, avoid kinks and 

connect it to the pump.

    

During normal filter operation, the sludge drain should be closed 

using the cover cap.

    

To permanently fit a 2” hose to the sludge drain, unscrew the 

cover cap from the dirt drain, push the union nut over the 2” hoze 

nozzle, push on the hose and secure with the hose clip, insert 

the flat sealing ring in the union nut and firmly screw-tighten the 

2” hose nozzle including the union nut on the dirt drain.

    

As an option, you can permanently fit a 1/2” connection for a 

garden hose to the fresh water connection and to connect the 

OASE pond aerator AQUAOXY 400 to the air connection to 

ensure an adequate oxygen supply to the pond.

1.

 

 

 

 

 

 

 

 

2.

 

 

 

 

 

 

 

 

3.

 

 

 

 

 

 

 

 

Содержание 56929

Страница 1: ...BioSmart 5000 10000 Operating instructions Notice d emploi Instrucciones de uso...

Страница 2: ...URNING TO STORE Part Description QTY A Container for pond additives 1 B Water supply 1 C Slide valve 1 D Sludge drain 1 E Filter cleaning Handle function 4 F Water level indicator 1 G Water drain 1 H...

Страница 3: ...ctrical voltage This symbol indicates an imminent danger which can lead to death or severe injuries if the appropriate measures are not taken Risk of personal injury caused by a general source of dang...

Страница 4: ...stepped hose nozzle through the water inlet insert an O ring on the thread from inside screw the inlet nozzle on the stepped hose nozzle from inside ensuring that the opening points downward Close th...

Страница 5: ...y clean the unit when required do not use chemical cleaning agents to permit the filter biology to optimally develop knowing that cleaning agents kill the bacteria in the foam filters Clean the filter...

Страница 6: ...several weeks Inadequate pump capacity Readjust the pump capacity Water extremely soiled Remove algae and leaves from the pond perform a partial water change Foam filters soiled Clean foam filters Exc...

Страница 7: ...livingwater com Vous pouvez aussi consulter notre site web au www oase livingwater com 6 RAPPEL APPELEZ LE 1 866 627 3435 AVANT DE RETOURNER AU MAGASIN Pi ce Description Quant A R cipient pour additi...

Страница 8: ...ET MISES EN GARDE Pictogrammes utilis s dans ces instructions Les pictogrammes utilis s dans ce manuel d utilisation ont les significations suivantes Risque de blessures aux personnes en raison de la...

Страница 9: ...uyau souple Enfiler une garniture plate sur le filetage de l embout olive ins rer le filetage de l embout olive travers l arriv e d eau enfiler de l ext rieur un joint torique sur le filetage visser p...

Страница 10: ...on lectrique dangereuse Cons quences possibles mort ou risque de blessures Mesures de protection Retirez la prise de secteur de tous les appareils se trouvant dans l eau avant de toucher l eau Retirez...

Страница 11: ...es Entreposage hivernage Mettre l appareil hors service si la temp rature de l eau est inf rieure 46 F 8 C ou en cas de risque de gel Vidanger l appareil proc der un nettoyage soigneux et v rifier l a...

Страница 12: ...Descripci n Cant A Recipientes para los complementos de estanque 1 B Entrada de agua 1 C V lvula de cierre 1 D Salida de agua sucia 1 E Limpieza del filtro Funci n de manejo 4 F Indicador del nivel de...

Страница 13: ...s siguientes restricciones de uso de la unidad La distancia de seguridad del equipo al estanque tiene que ser como m nimo de 6 6 ft 2 m No transporte nunca otros l quidos que no sea el agua No emplee...

Страница 14: ...ntrada de agua coloque un anillo en O por adentro en la rosca y atornille la tobera de entrada por adentro en la boquilla portatubo escalonada de forma que la abertura indique hacia abajo Cierre la se...

Страница 15: ...ta el procedimiento de limpieza si fuera necesario 2 a 3 veces Si fuera necesario saque los elementos de espuma filtrantes y l mpielos bajo agua clara Presione para esto el dispositivo enclavador de l...

Страница 16: ...el portaespuma Coloque la tapa interior en el recipiente de filtro y coloque todas las grapas hacia arriba Coloque despu s la tapa del filtro y conecte la bomba Si el flotador del indicador del nivel...

Страница 17: ...Elementos de espuma filtrantes verde Temperatura del agua Dimensiones Peso 5000 56929 max 1450 GPH max 5500 LPH 1 1 25 38 mm DN 70 4 101 6 mm 2 1 1 min 46 F min 8 C 15 x 22 x 16 in 385 x 555 x 408 mm...

Страница 18: ...18...

Страница 19: ...19 18...

Страница 20: ...OASE North America INC www oase livingwater com 23867 11 16...

Отзывы: