background image

The tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is 

rated for the table. (See Grounding below)
Arrange the power cord and control cords so that they will not create a tripping hazard.
Be sure access to the plug is not blocked for disconnecting the table from power.

GROUNDING FOR 120 VOLT PRODUCTS WITHOUT WARMING DRAWER:
This product is for use on a nominal 120-volt circuit and has a grounding plug that looks like the plug 

shown below. See Grounding Methods - US 120V Example. Make sure that the product is connected 

to an outlet having the same configuration as the plug. No adapter should be used with this product.

 

Grounding for 120 Volt products with warming drawer:
This product is rated for more than 15 amperes and is for use on a circuit having a nominal rating of 

120 volts and is factory-equipped with specific electric plug to permit connection to a proper circuit. 

Make sure that the product is connected to an outlet having the same configuration as the plug. No 

adapter should be used.
Grounding for 230 Volt products:
This product is rated for less than 15 amperes and is for use on a circuit having a nominal rating 

of 230 volts and is factory-equipped with specific electric plug to permit connection to a proper 

circuit. Make sure that the product is connected to an outlet having the same configuration as the 

plug. No adapter should be used.

WARNING

1.  Improper connection of the equipment-grounding conductor can result in a risk of  electric 

shock. Check with a qualified electrician or service person if you are in doubt as to whether 

the product is properly grounded.

2.  Do not modify the plug provided with the product - if it will not fit the outlet; have a proper 

outlet installed by a qualified electrician.

Correct Implementation

Incorrect Implementation

Risk of Electric Shock - Connect this furnishing to a properly grounded outlet only.

DANGER

INSTALLATION

GROUNDING

Grounding Methods - US 120V Example

For electrical specs, see Specifications section.

11

Содержание Masters Britta Fuzion Top

Страница 1: ...USER MANUAL www OAKWORKS com 717 235 6807 made in the with US imported Icon Series Talise Series Cosmo Series Maia Series Legacy Series Britta Series Palas Series OAKWORKS Masters Collection Tables...

Страница 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifica tions and the like documen...

Страница 3: ...perations 1 Section Flat Top Tables Only 18 1 Section Britta and Palas Flat Top Tables Only 19 4 Section Salon Top Tables Only 20 4 Section Britta and Palas Salon Top Tables Only 21 Adjustable Breast...

Страница 4: ...es that when the end user wishes to discard this product it must be sent to separate collection facilities for recovery and recycling U L 2601 1 C S A C 22 2 N O 601 1 IE C 60601 2 2001 09 C U S U S L...

Страница 5: ...roducts are being used or where oxygen is being administered 7 Use this furnishing only for its intended use as described in these instructions Do not use attachments not recommended by the manufactur...

Страница 6: ...8 Do not place foreign objects into the ABC System 9 Only use the ABC system as intended 10 For safety of your client use a cloth sheet between the ABC System and your client 11 Be certain that the t...

Страница 7: ...Control All powered motions and Memory Positions Boiance Shelf Support OF SHEET SCALE PART NO FILE NAME DESIGNER THIS DOCUMENT CONTAINS TECHNICAL INFORMATION PROPRIETARY TO OAKWORKS INC THE DISCLOSUR...

Страница 8: ...V 4 Section Salon Top 4 Section Fuzion Top 120V or 230V ABC MODEL 5 OF SHEET SCALE PART NO FILE NAME DESIGNER THIS DOCUMENT CONTAINS TECHNICAL INFORMATION PROPRIETARY TO OAKWORKS INC THE DISCLOSURE TO...

Страница 9: ...or 230V 4 Section Salon Top 4 Section Fuzion Top 120V or 230V ABC MODEL OF SHEET SCALE PART NO FILE NAME DESIGNER THIS DOCUMENT CONTAINS TECHNICAL INFORMATION PROPRIETARY TO OAKWORKS INC THE DISCLOSUR...

Страница 10: ...e Cabinet 41 L x 24 D x 11 H Storage Load Capacity 75 lbs Warming Drawer Inside Area 19 D x 17 W x 3 H Warming Drawer Capacity 16L OF SHEET SCALE PART NO FILE NAME DESIGNER THIS DOCUMENT CONTAINS TECH...

Страница 11: ...Warming Drawer Capacity 16L UPHOLSTERED TOP MODELS 1 Section Flat Top 1 Section Fuzion Top 120v or 230v 4 Section Salon Top 4 Section Fuzion Top 120v or 230v OF SHEET SCALE PART NO FILE NAME DESIGNER...

Страница 12: ...88 cm Height with 4 foam 4 Section Table Motions 1 Powered 20 5 34 5 52 88 cm Height with 4 foam 2 Powered 17 Trendelenburg ReverseTrendelenburg 2 Powered 0 80 Backrest Foot Control All powered motion...

Страница 13: ...ding 4 10 cm or 6 15 cm AeroLux Foam Table Voltage 120V 60Hz or 230V 50Hz OPTIONS ACCESSORIES 120V or 230V Outlets 2nd Foot Control 2nd Hand Control All powered motions and Memory Positions Boiance Sh...

Страница 14: ...roper circuit Make sure that the product is connected to an outlet having the same configuration as the plug No adapter should be used Grounding for 230 Volt products This product is rated for less th...

Страница 15: ...ace anything between the metal frame and the base structure as damage can occur to the table The 1 Section Flat Top Tables offer height positioning with electronic ease Operate the foot control as sho...

Страница 16: ...anything between the metal frame and the base structure as damage can occur to the table The 1 Section Britta and Palas Tables offer trendelenburg and height positioning with electronic ease Operate t...

Страница 17: ...T use this area for holding anything as damage can occur to the table The 4 Section Salon Top Tables offer backrest height and footrest positioning with electronic ease Operate the foot control as sho...

Страница 18: ...this area for holding anything Damage can occur to the table The 4 Section Britta and Palas Salon Tables offer trendelenburg height backrest and footrest positioning with electronic ease Operate the f...

Страница 19: ...stem and your client The OAKWORKS Adjustable Breast Comfort ABC System is designed to lower the pressure on breasts and pectoral muscles allowing the client to relax and create a more comfortable posi...

Страница 20: ...lbs 45 kg Do not place foreign objects into the ABC System Only use the ABC System as intended For safety of your client use a cloth sheet between the ABC System and your client The OAKWORKS Adjustab...

Страница 21: ...ight positioning and memory positions with electronic ease Operate the hand control as shown below to raise or lower the height of the table Use either of the top 2 buttons to orient the table in a fa...

Страница 22: ...te position To store the current position in memory press the MEM button twice double click Two audi ble beeps will confirm To recall a stored position press hold the MEM button MEMORY FUNCTION USE 19...

Страница 23: ...electronic ease Operate the hand control as shown below to raise or lower the backrest height or footrest functions of the table Use either of the top 8 buttons to orient the table in a favorite posit...

Страница 24: ...ory press the MEM button twice double click Two audi ble beeps will confirm To recall a stored position press hold the MEM button MEMORY FUNCTION USE The 4 Section Britta and Palas Salon Tables offer...

Страница 25: ...ht of the cushion is easily adjusted up and down in small increments by using the hand control 4 SECTION SALON TOP TABLES ONLY 1 SECTION FLAT TOP TABLES ONLY ABC SYSTEM UP ABC SYSTEM DOWN ABC System U...

Страница 26: ...adjusted up and down in small increments by using the hand control ABC SYSTEM UP ABC SYSTEM DOWN ABC System Weight Limit 100 lbs 45 kg Do not place foreign objects into the ABC System Only use the ABC...

Страница 27: ...l motions It should be used to prevent unauthorized use Remove the key when not in use and store out of reach of children The green light on the switch indicates the table is on Key Lock Use I Unlocks...

Страница 28: ...le Sometimes going back up a little will be preferred This whole process takes no more than 15 20 seconds After lowering check headrest position to ensurecomfort support NOTE Breastsizeisnottheonlydet...

Страница 29: ...into the bracket until bullet catches are snapped into place To remove the QuickLock Face Rest gently pull the headrest by the dowels until it comes free Set it safely aside or store it inside the un...

Страница 30: ...head support Note The QuickLock Face Rest is required to use the boiance shelf support system TO INSTALL THE BOIANCE SHELF SUPPORT First install the QuickLock Face Rest at the head end of the table 1...

Страница 31: ...rocedure Because of possible chemical incompatibilities between various cleaning products and bleach utmost care must be taken by the user to avoid potential exposure to harmful or toxic by prod ucts...

Страница 32: ...control and foot control cables and all visible wiring Visually inspect components for obvious damage that could cause problems during operation Check all mechanical functions using the hand control R...

Страница 33: ...lspring Rd New Freedom PA 17349 USA Phone 717 235 6807 www oakworks com 16796025 MIXX4R35ASH611USXXXSAGEAGIDPCXXDXX Ser MIS563146 07 18 2017 Order 785461 Maia 4 Sect XX 4 R 3 5 A SH 6 11 US XXX AS Sha...

Страница 34: ...60Hz 5 0 Amps 120V 60Hz 3 0 Amps 120V 60Hz 11 0 Amps 120V 60Hz 9 0 Amps 120V 60Hz 16 0 Amps Plug Type s Type B Plug NEMA 5 15 NEMA 5 20 Plug Mode of Operation 10 Duty Cycle MAX 2 minutes ON 18 minutes...

Страница 35: ...applicable regulations and require ments of the local state environmental protection agency state health agency Centers for Disease Control CDC Occupational Safety and Health Administration OSHA U S F...

Страница 36: ...tional Radiators NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonab...