background image

20

SPECIFICATIONS

Guidance and manufacturer’s declaration - electromagnetic immunity

The table is intended for use in the electromagnetic environment specified below. The customer or the user of the 

table should assure that it is used in such an environment.

Immunity Test IEC 60601 test level Compliance level

Electromagnetic

environment - guidance

Conducted RF 

IEC 61000-4-6

Radiated RF

IEC 61000-4-3

3 Vrms

150 kHz to 80 MHz

3 V/m

80 MHz to 2,5 GHz

3Vrms

3V/m

Portable and mobile RF communications equipment 

should be used no closer to any part of the table, includ-

ing cables, than the recommended separation distance 

calculated from the equation applicable to the frequency 

of the transmitter.

Recommended separation distance

d = 1.2 

 P

 

d = 1.2 

 P

   80 MHz to 800 MHz

d = 2.3 

 P 

  800 MHz to 2,5 GHz

Where P is the maximum output power rating of the trans-

mitter in watts (W) according to the transmitter manufac-

turer and d is the recommended separation distance in 

meters (m).

Field strengths from fixed RF transmitters, as deter-mined 

by an electromagnetic site survey, 

a

should be less than 

the compliance level in each frequency range. 

b

Interference may occur in the vicinity of equipment 

marked with the following symbol:

NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.

NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection 

from structures, objects and people.

a

  Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, 

amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the 

electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured 

field strength in the location in which the table is used exceeds the applicable RF compliance level above, the table should be 

observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-

orienting or relocating the table

b

  Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.

Содержание DTPM 300

Страница 1: ...USER MANUAL www oakworksmed com 717 235 6807 made in the USA with US imported parts OAKWORKS DTPM 300 Imaging Table...

Страница 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifications and the like documen...

Страница 3: ...Fiber Arm Board 10 Fluoro Extender 10 Spine Positioning System II 11 Locking Casters Use 11 Reference Usable Imaging Area Diagrams 12 13 Cleaning Disinfection Recommended Cleaners Disinfectants 14 Cle...

Страница 4: ...is not designed for and should not be used with Magnetic Resonance Imaging procedures Although the table accommodates a number of procedures it is not intended to serve as a surgical procedure table S...

Страница 5: ...ed Both locking knobs must be securely tightened at all times Travel can occur if the locking knobs are not secured by inadvertently pushing on the end of the table or by tilting the table The table u...

Страница 6: ...ent exposure to scattered radiation from the x ray generat ing source Oakworks Imaging Tables may be used for x ray imaging where the x ray generator is located below the tabletop and the image recept...

Страница 7: ...ge Op tions 120V 60Hz or 230V 50Hz Table Capacity 450 lbs 205 kg patient and accessories Polycarbonate Top 78 198 cm Long x 24 61 cm Wide 4 10 cm Locking Casters Locking Unlocking Casters for mobile o...

Страница 8: ...uct is equipped with a cord having an equipment grounding conductor and a grounding pin The pin must be plugged into an appropriate outlet that is proper ly installed and grounded in accordance with a...

Страница 9: ...peutic procedures DANGER Should the use of this device create a circumstance under which the patient could be overexposed to ionizing radiation discontinue use immediately and determine an alternative...

Страница 10: ...all cautions and warnings Reverse Trendelenburg activates tilt up to 14 positioning stops when table is level press again for complete reverse Trendelenburg activates tilt up to 14 positioning stops w...

Страница 11: ...ide of the table just under the side rail Rotate the locking knob several turns counter clockwise to loosen Slide the table in the desired direction Rotate the locking knob clockwise until tight to se...

Страница 12: ...hen pressing the flaps in place anchoring the flaps to the Fastener Hook and Loop Faster as shown applies to both the 1 2 5 cm 2 5 cm pads Hook and Loop Faster All electric tables are equipped with an...

Страница 13: ...cedure The weight of the patient will hold the Arm Board in place Rotate the Support Section to the desired position This section rotates up to 180 Prone Position at 135 Supine Position at 180 Support...

Страница 14: ...ARGE RECTANGULAR ADJUSTER PAD 7 X 12 X 1 18cm x 31cm x 4cm SMALL RECTANGULAR ADJUSTER PAD 8 20 CM SEMI ROUND BOLSTER All four casters should be locked at all times during use with a patient LOCKING CA...

Страница 15: ...M 37 93 96 33 CM 16 57 CM 12 01 30 51 CM 12 01 30 52 CM 6 52 16 57 CM 37 93 96 33 CM 6 52 16 57 CM 12 01 30 51 CM 16 34 41 50 CM 19 88 50 48 CM 7 85 19 93 CM 7 02 17 84 CM 34 49 87 61 CM 7 02 17 84 CM...

Страница 16: ...13 REFERENCE OFFSET FOR A P VIEW OFFSET CAUDAL 30 VIEW FROM VERTICAL NO IMAGE NO IMAGE NO IMAGE NO IMAGE...

Страница 17: ...cquer plated metals 2 Clorox Hydrogen Peroxide Disinfectant EPA reg 67619 24 corrosion of metals deterioration of upholstery and wood lacquer leaves a hard to remove residue 3 Virox Accel TB EPA reg 7...

Страница 18: ...ain wet for the disinfectant manufacturer s recommended contact time 4 Throw the used wipe s away and allow the table to dry INSPECTIONS RECOMMENDED REGULAR INSPECTIONS monthly or local standard Check...

Страница 19: ...CRIPTION FL DT RT 22 26 84 MG TT XX XX Fluoroscopy Table Base Motion Dual Tower Top Polycarbonate RT Rectangular Table Top Width Minimum Table Height Table Top Length Padding Comfort Foam Fabric Terra...

Страница 20: ...e standards 21 CFR Subchapter I in effect at the time of manufacture for radiographic tables ENVIRONMENTAL CONDITIONS Conditions Temperature Humidity Atmospheric Pressure Normal Use 50 10 C to 104 40...

Страница 21: ...magnetic environment in which radiated RF disturbances are con trolled the customer or the user of the table can help prevent electromagnetic interference by maintaining a minimum distance between por...

Страница 22: ...2 kV line s to earth 1 kV line s to line s 2 kV line s to earth Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interrup tions and voltage variati...

Страница 23: ...d RF transmitters as deter mined by an electromagnetic site survey ashould be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with t...

Страница 24: ...g Road New Freedom PA 17349 Phone 717 235 6807 FAX 717 235 6798 www oakworksmed com made in the USA with US imported parts 3034177 CONFORMS TO ANSI AAMI STD ES60601 1 IEC STD 60601 1 3RD EDITION IEC S...

Отзывы: