CLEANING & DISINFECTION

RECOMMENDED CLEANERS/DISINFECTANTS

To reduce the risk of electric shock:

-  Always unplug this furnishing from the electrical outlet before cleaning.

DANGER

The following cleaners were tested by OAKWORKS® and found to be acceptably compatible with all materials used in 

construction of our tables:

1.  Formula 409

®

2.  Fantastik

®

3.  Green Windex

®

The following disinfectants were tested by OAKWORKS® and found to be acceptably compatible with all materials 

used in construction of our tables:

1.   Parker Labs: Protex

TM

 (EPA reg# 6836-152-82613)

2.  Healthlink

®

 E-Z Kill

®

 (EPA reg# 59894-10-67454)

3.  MADA Medical: Madacide-FD (EPA reg# 1130-15-11703)

The following disinfectants were tested by OAKWORKS® and found to be acceptably compatible with most materials, 

with some cautions as indicated:

1.  10% Sodium Hypochlorite (bleach) solution in water (EPA reg# 5813-100) (possible mild corrosion of  

 

plated metals)

2.  Metrex Cavicide One (EPA reg# 46781-12) (possible slight deterioration of upholstery and wood lacquer)

OAKWORKS® recommends a prepackaged wipe for cleaners/disinfectants to ensure best distribution of disinfectant 

for the required kill time, without leaving excess residue and/or overexposing components therefore minimizing the 

potential for damage to materials. Please read and follow disinfectants manufacturers’ directions for cleaning and dis-

infection.

The following disinfectants were tested by OAKWORKS® and found to be incompatible with some materials and are 

therefore NOT recommended for use:

1.  Clorox Broad Spectrum Quaternary (EPA reg# 67619-20)(deterioration of upholstery, wood lacquer,  

 

plated metals)

2.  Clorox Hydrogen Peroxide Disinfectant (EPA reg# 67619-24)(corrosion of metals, deterioration of    

upholstery and wood lacquer, leaves a hard-to-remove residue)

3.  Virox Accel TB (EPA reg# 74559-1)(corrosion of metals, deterioration of upholstery and wood lacquer,  

leaves a hard-to-remove residue)

4.  Clorox Healthcare Bleach Germicidal Cleaner (EPA reg# 56392-7)(deteriorates upholstery, wood    

 

lacquer, mild corrosion of metals, dissolves foam in pads)

OAKWORKS® does NOT recommend the use of cleaners/disinfectants containing Hydrogen Peroxide, Acetic Acid, or 

Phenolics. These chemicals can cause damage to the appearance and/or material integrity of various components. 

Also, while the recommended cleaners/disinfectants list includes products containing Quaternary Ammonium com-

pounds (“quats”), not all products containing quats are approved for use. Some contain additional detergents and/or 

surfactants which can be detrimental to some materials. 

A note on Bleach: While a 10% sodium hypochlorite (household bleach) solution (EPA reg# 5813-100 or equivalent) 

can be an effective disinfectant and is dilute enough to be benign to most materials, it alone is not an effective clean-

er and a separate product must be used for the initial cleaning steps of the procedure. Because of possible chemical 

incompatibilities between various cleaning products and bleach, utmost care must be taken by the user to avoid 

potential exposure to harmful or toxic by-products of the combination. Also, because bleach leaves a potentially cor-

rosive residue as it evaporates, it must be rinsed with clean water after disinfection. It is therefore NOT recommended 

by OAKWORKS®. Please note, one step cleaner/disinfectants using bleach and a detergent/ surfactant were found to 

damage materials and are NOT recommended.

Содержание PF Series

Страница 1: ...L www oakworksmed com 717 235 6807 made in the USA with US imported parts PF250 PF200 Shown with optional QuickLock Face rest platform and Boiance crescent PF400 Shown with optional Adjustable Side Ar...

Страница 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifications and the like documen...

Страница 3: ...rest Adjustment 12 Lowered Arm Rest Use 12 Locking Casters Use 13 Table Extender 13 Adjustable Arm Rest Installation and Adjustment 14 QuickLock Face Rest 15 Cleaning Disinfection Recommended Cleaners...

Страница 4: ...Terminal This symbol when used in this manual or on product labels indicates that the product should be protected from moisture The humidity specifications for Transport Storage are listed in the env...

Страница 5: ...thetic mixture with air or oxygen or nitrous oxide Do not lift the table by the table top This can damage the table When lowering the table or using the Trendelenburg functions make sure there is noth...

Страница 6: ...0 kg patient and accessories Widths 27 69 cm 29 74 cm 31 79 cm or 33 84 cm Length 4 section 72 183 cm Padding 4 10 cm Comfort Foam Upholstery Terra Touch Wood Stain Natural Maple Finish Table Weight 2...

Страница 7: ...s 250 kg patient and accessories Widths 27 69 cm 29 74 cm 31 79 cm or 33 84 cm Length 2 section 74 188 cm Padding 3 8 cm Comfort Foam Upholstery Terra Touch Wood Stain Natural Maple Finish Table Weigh...

Страница 8: ...patient and accessories Widths 27 69 cm 29 74 cm 31 79 cm or 33 84 cm Length 2 section 73 185 cm Padding 3 8 cm Comfort Foam Upholstery Terra Touch Wood Stain Natural Maple Finish Table Weight 212 lb...

Страница 9: ...is equipped with a cord having an equipment grounding conductor and a grounding pin The pin must be plugged into an appropriate outlet that is prop erly installed and grounded in accordance with all l...

Страница 10: ...anything Damage can occur to the table The PF400 Tables offer trendelenburg height backrest and footrest positioning with electronic ease Operate the foot control as shown below to raise or lower the...

Страница 11: ...or holding anything Damage can occur to the table The PF250 PF200 tables offer trendelenburg and height positioning with electronic ease Operate the foot control as shown below to raise or lower the t...

Страница 12: ...his area for holding anything Damage can occur to the table The PF400 Tables offer trendelenburg height backrest and footrest positioning with electronic ease Operate the optional hand control as show...

Страница 13: ...nder the backrest top is not designed for storage DO NOT use this area for holding anything Damage can occur to the table The PF250 PF200 tables offer trendelenburg and height positioning with electro...

Страница 14: ...use the table to transport a patient 11 DIRECTIONS FOR USE Grasp at base corner at low height range 1 2 13mm Open end Wrench Leveler Foot 1 Place the table in the location where you plan to use it 2...

Страница 15: ...side of the back rest by removing the screws and relocating the hand lever to the opposite side of the top into the four pre drilled holes Back Rest Control The Lowered Arm Rest can be removed when no...

Страница 16: ...CKING THE CASTERS 1 Place your shoe on top of the casters locking tab 2 Press firmly inward and downward until you here a click ing noise and the caster is unlocked CAUTION TABLE EXTENDER USE Do not p...

Страница 17: ...rm rest at a 60 angle to the backrest 2 Push end all the way into the hole and drop the arm rest into the horizontal position Pull outward to make sure the arm rest is secure TO LEVEL THE ARM RESTS Th...

Страница 18: ...ting for height and angle and then locking the cam locks into the desired position Important Safety Note Maximum Distance from edge of Table 3 7 6 cm QuickLock Face Rest Insert dowels into Accessory a...

Страница 19: ...cquer plated metals 2 Clorox Hydrogen Peroxide Disinfectant EPA reg 67619 24 corrosion of metals deterioration of upholstery and wood lacquer leaves a hard to remove residue 3 Virox Accel TB EPA reg 7...

Страница 20: ...ain wet for the disinfectant manufacturer s recommended contact time 4 Throw the used wipe s away and allow the table to dry INSPECTIONS RECOMMENDED REGULAR INSPECTIONS monthly or local standard Check...

Страница 21: ...Series Exam Table Exam Base Top FT Flat PF200 LB Lift Assist PF250 ES Electric PF400 Table Width Minimum Table Height Table Top Length Padding PL 3 AC 4 Fabric TerraTouch Grommets Options Model Number...

Страница 22: ...ICAL SPECIFICATIONS Designed for North America Europe Input Service 120 VAC 15 amp 60 Hz 220 VAC 10 amp 50 60 Hz Current Draw 4 0 amps 2 0 amps Maximum Momentary Current Consumption 6 0 amps 3 0 amps...

Страница 23: ...netic environment in which radiated RF disturbances are controlled the customer or the user of the table can help prevent electromagnetic interference by maintaining a minimum distance between portabl...

Страница 24: ...de 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical com mercial or hospital environ ment Voltage dips short inter ruptions and voltage variation...

Страница 25: ...RF transmitters as deter mined by an electromagnetic site survey ashould be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with th...

Страница 26: ...23 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 27: ...24 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 28: ...m PA 17349 Phone 717 235 6807 FAX 717 235 6798 www oakworksmed com made in the USA with US imported parts 3034177 CONFORMS TO ANSI AAMI STD ES60601 1 IEC STD 60601 1 3RD EDITION IEC STD 60601 1 2 3RD...

Отзывы: