background image

Instruction Manual 

                                                           Temp 4/5/6 

 

17

9.  WARRANTY  & RETURN OF ITEMS 

This meter is supplied with a warranty against significant deviations in material 
and workmanship for a period of 

THREE

 years from date of purchase whereas 

probe with a 

SIX

-month warranty.  

If repair or adjustment is necessary and has not been the result of abuse or 
misuse within the designated period, please return – freight pre-paid – and 
correction will be made without charge.  Eutech Instruments/ Oakton 
Instruments will determine if the product problem is due to deviations or 
customer misuse.   

Out of warranty products will be repaired on a charged basis.  

 

Exclusions 

The warranty on your instrument shall not apply to defects resulting from: 

 

Improper or inadequate maintenance by customer 

 

Unauthorized modification or misuse 

 

Operation outside of the environment specifications of the products 

 

Содержание Temp 4/5/6

Страница 1: ...1 Technology Made Easy Instruction Manual Temp 4 5 6 Temperature Meter Series 68X243607 Rev 2 01 03...

Страница 2: ...use of this meter please do not hesitate to contact the nearest Eutech Instruments Oakton Instruments Authorized Distributor Eutech Instruments Oakton Instruments will not accept any responsibility fo...

Страница 3: ...the Meter On 9 3 CALIBRATION 10 3 1 Temperature Calibration 10 3 1 1 Temperature Calibration using Offset Adjustment 10 3 1 2 Temperature Curve Selection Temp 5 Meter Only 11 4 MEASUREMENT 12 4 1 Tak...

Страница 4: ...m hold mode Low battery indicator Hold function freezes measured reading User calibration offset adjustment Built in memory backup calibration and other information remain if battery is disconnected T...

Страница 5: ...HOLD ENTER Freezes the measured reading confirm calibration value MAX S UP and MIN T DOWN Momentarily displays meter s maximum and minimum temperature enter maximum or minimum hold mode scroll up and...

Страница 6: ...edges of meter until it is completely out of boot Ensure that the connector of temperature sensor is not connected 2 To insert meter into rubber boot slide in from the top of meter before pushing the...

Страница 7: ...tery compartment is found at the back of instrument To open the battery compartment push in the direction of arrow and lift up the cover Note the polarity of battery before inserting into position Aft...

Страница 8: ...manufacturer Caution Power off the meter when changing battery 2 6 Connecting the Temperature Sensor To connect a temperature probe into the meter align the connector of probe to the meter s socket a...

Страница 9: ...r All the LCD segments display momentarily as the meter performs a self diagnostic test per shown in section 2 2 The LCD then switches into measurement mode 2 The LCD displays oPEn if the temperature...

Страница 10: ...meter Dip the probe in a constant temperature bath or a liquid whose temperature can be checked with a thermometer known to be accurate For best accuracy place the probe and thermometer in a constant...

Страница 11: ...n the measurement mode Press CAL key to enter calibration mode The LCD shows CA and the reading flashes 3 Press o C o F key to enter curve selection mode Press the o C o F key again to scroll through...

Страница 12: ...4 2 Displaying Maximum and Minimum Readings The EcoScan Temp meter can momentarily display the maximum and minimum temperature measured since you switched the meter on Simply press MAX S or MIN T key...

Страница 13: ...nce entering the Maximum or Minimum Hold mode 1 Power on the meter The meter automatically enters Temperature mode Use o C o F key to switch between Celsius and Fahrenheit reading if desired 2 Press H...

Страница 14: ...both the probe and meter into its original packaging when not in use 6 TROUBLESHOOTING Problem Cause Solution Power on but no display a Batteries not in place a Insert batteries b Re insert batteries...

Страница 15: ...9 o C 99 9 o F and range 199 9 o C 391 9 o F Accuracy 0 2 o C 0 4 o F 0 2 o C 0 4 o F 99 9 to 199 9 o C 99 9 to 391 9 o F 2 o C 4 o F range 99 9 o C 99 9 o F and range 199 9 o C 391 9 o F Hold Functio...

Страница 16: ...00 35626 00 General Purpose Probe 93824 00 Temp 5 Meter with probe EC TEMP5 01 35626 10 100K Thermistor Temperature probe EC TEM5TEM01P 35626 50 Temp 6 Meter with probe EC TEMP6 01 Temp 6 Meter only...

Страница 17: ...misuse within the designated period please return freight pre paid and correction will be made without charge Eutech Instruments Oakton Instruments will determine if the product problem is due to dev...

Страница 18: ...he reason the items are to be returned For your protection items must be carefully packed to prevent damage in shipment and insured against possible damage or loss Eutech Instruments Oakton Instrument...

Страница 19: ...NOTES...

Страница 20: ...ruments P O Box 5136 Vernon Hills IL60061 USA Tel in U S 888 462 5866 Tel outside U S 1 847 549 7600 Fax 1 847 247 2984 E mail info 4oakton com www 4oakton com Eutech Instruments Pte Ltd Blk 55 Ayer R...