Operating Instructions

NOTE: All multi-fuelled stoves must be installed by an approved installer, and all 

necessary checks described in the Installation Instructions need to be carried out. 

Only use the recommended fuels detailed below.

Recommended Fuels

The  Zeta  stoves  are  Multi-Fuel  appliances,  meaning  they  can  burn  a  number  of  different 

fuels, however you must ensure that you follow the instructions specific to your chosen type 

of fuel and that your chimney is suitable for all the types of fuel you will use.

Wood

The wood you use to burn in this stove should only be dry and well seasoned. To prepare the 

wood for burning ensure it is cut, split and then left to season in a dry, well ventilated area for 

at least one year before burning. The ideal types of wood for this stove are hard woods such 

as Ash, Beech or Oak. We recommend that all wood has a moisture content of less than 20%.

The firebox should have a bed of ash at the base for the wood to be placed on. The use of 

unseasoned wood in this appliance can result in heavy tar deposits in the stove, on the glass 

and within the chimney. Also unseasoned wood will produce lower outputs from the fire.

Peat

Cut peat must be dried before using in the stove in order to reduce the amount of tar deposits 

produced. You should burn Peat in the same way as wood fuel, on a bed of ash at the base 

of the stove.

Smokeless Fuel (Solid Mineral Fuels)

A variety of smokeless fuels may be used in this stove, however you must check the necessary 

precautions for each specific fuel to prevent damage. These fuels include:

• Ancit

• Anthracite Large Nuts

• Centurion

• Extracite

• Homefire

• Maxibrite

• Phurnacite

Only smokeless fuels may be burnt in smoke control areas. Petroleum Coke and House Coal 

is not suitable for use on this appliance, it’s use will void your warranty.

There are a few additional points to consider when lighting smokeless fuel fires, please refer 

to the ‘Burning solid mineral fuels’ section on the next page. Also when burning smokeless 

fuels, the upper baffle vermiculite board (throat plate fireboard) must be removed. Please 

refer to page 19 for instructions on how to do this.

Oper

a

ting Ins

tructions

Содержание ZETA5PW

Страница 1: ...The Zeta 5 Window Series ZETA5CW ZETA5PW ZETA5LW Manual Operation Installation sales oakstoves co uk www oakstoves co uk...

Страница 2: ...e paint will be properly cured and you can operate your stove normally according to the instructions provided in this manual If any peeling of the paint occurs on your stove this will only be as a res...

Страница 3: ...y Cleaning 10 Chimney Sweeping 11 Combustion Air Supply 11 Seasonal Use 11 Troubleshooting 12 Placement Fixing Advice 13 Installation Instructions Health Safety Precautions 15 Chimney 15 Hearth Fire S...

Страница 4: ...OOD SOLID MINERAL FUEL NOMINAL OUTPUT 4 9kW 4 1kW ENERGY EFFICIENCY NET 76 7 77 7 Ancit CO EMISSION AT 13 OXYGEN 0 47 0 21 CLEARANCE TO COMBUSTIBLE MATERIAL MINIMUM 75mm REAR 500mm SIDE 75mm REAR 500m...

Страница 5: ...ALLER NAME INSTALLER ADDRESS Important To Remember Installation By Authorised Technician This manual contains instructions on how the stoves must be assembled maintained and installed To ensure the fu...

Страница 6: ...to be placed on The use of unseasoned wood in this appliance can result in heavy tar deposits in the stove on the glass and within the chimney Also unseasoned wood will produce lower outputs from the...

Страница 7: ...balancing valve which you never need to touch fitted into the rear of the stove that automatically manages the volume of air being fed to each of the outlet air controls so the optimum airflow is deli...

Страница 8: ...he base of the firebox and cover with approximately 50mm of fuel Light the paper or fire lighters to start the fire then ensure the right hand primary air slider is open See Fig 1 on the stove before...

Страница 9: ...or long periods then over firing may occur Once lit we recommend the primary slider be left slightly open and adjust accordingly to control the fire The door handle two control bars air wash and prima...

Страница 10: ...t to do this as this ash must not be allowed to overflow over the grate This model has a Remote Riddle Plate Handle located under the left side of the door pulling this bar will rotate the grills allo...

Страница 11: ...Provision of air to the stove must be in accordance with current Building Regulations Approved Document J An open window is not appropriate Any air inlets must be positioned in such a way as they cann...

Страница 12: ...ss still occurs ensure that all flue connections are well sealed with fire cement as this can decay over a long period of time and may need resealing Also the chimney draw needs to be sufficient and n...

Страница 13: ...ppened and the stove has cooled you must then clean the chimney and flueways to prevent the chimney fire from reoccurring next time you light the stove If the chimney fire does not extinguish after cl...

Страница 14: ...s 1000mm from the window and ends in line with each side of the door edge This area can be 90o C so we do not recommend any combustibles in this area Fixing Points If you would like to fix the stove t...

Страница 15: ...smoke alarm fitted in the same room as the appliance Chimney For the stove to perform correctly and safely your chimney height must not be less than 4 metres high this height is taken from the outlet...

Страница 16: ...to your chosen type of installation are conformed to before you begin to use the stove Your stove will normally be delivered assembled ready for connection Connecting The Flue The flue collar must be...

Страница 17: ...5mm E 420mm F 470mm G 150mm H 420mm The Zeta Pedestal 5kW Model ZETA5PW A 1050mm B 125mm C 300mm D 800mm E 500mm F 420mm G 470mm H 195mm I 240mm J 150mm K 420mm Front View Side View Front View Side Vi...

Страница 18: ...510 Baffle Deflector Fireboard N 11 1 Z511 Side Panel Y 12 1 Z512 Regulator Cover Plate Y 13 1 Z513 Pneumatic Door Closer N 14 1 Z514 Ash Pan N Item Qty Part No Description Warranty 15 1 Z515 Zeta 5 C...

Страница 19: ...then fix in position by slotting the Retaining Plate under it with the lip facing down 2 Place Top Fireboard in position on its retainers 3 Put the two Rear Fireboards back into position before refitt...

Страница 20: ...so a condition of the Extended Warranty that your Oak Stoves is regularly serviced every 12 months by a suitably trained and qualified individual HETAS registered in the United Kingdom or equivalent i...

Страница 21: ...r other household assets l Delivery to or return transport costs Removal and re installation costs or any labour cost to fit parts Repaired or replaced products are covered only for the remainder of t...

Страница 22: ...or Minister in the devolved administrations Further information on the requirements of the Clean Air Act can be found at http smokecontrol defra gov uk Your local authority is responsible for implemen...

Страница 23: ...ries Manual V2 8 Oak Stoves 2018 23 What comes with your stove Manual Stove body with door and handle fitted Ash pan Ash pan handle Protective gloves Flue collar Fire grate retainer bars Riddle grate...

Страница 24: ...ut 76 7 8 Specific precautions See Manual 1 Supplier name or trademark Oak Stoves 2 Model identifier Zeta Pedestal Clean Burn Stove 3 Energy class A 4 Direct heat output 4 9kW 5 Indirect heat output N...

Отзывы: