O.W. Lee CASUAL FIRESIDE 51-08 Скачать руководство пользователя страница 3

GAS PRESSURE REQUIREMENTS:  FOR NATURAL GAS:

The minimum inlet gas supply pressure for purposes of input adjustment is

 3.5 inches

 (127 mm) water column and maximum 

inlet gas supply pressure is 

10 inches

 (254 mm) water column.

FOR PROPANE: 

 The minimum inlet gas supply pressure for purposes of input adjustment is 

8 inches

(203 mm) water column and the maximum inlet gas supply pressure is 

13 inches

 (330 mm) water column.

MANIFOLD PRESSURE REQUIREMENT

:   Liquid Propane 9.5 (241.3mm)  / Natural Gas 2.5 (63.5mm) of pressure.

DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED.

Page 3

SAFETY NOTE:  An secondary on/off valve, kept in the Off Position, in a fixed piping gas supply line before the fire pit 
is required for safety when your Outdoor Fire Pit is not in use.  It also provides for convenient maintenance and 
repair.

O.

D.

E.

Casual Fireside Fire Pits are suitable for installation from 0 - 4,500 ft. elevation without modification.

M.

F. Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr).  Undue 

pressure loss will occur if the pipe is too small or the run is too long.

A. Before installing the Outdoor Fire Pit, check “Minimum Clearance to Combustibles” on page 2.

MINIMUM CLEARANCES

 must be maintained when you install this Outdoor Fire Pit.  

THERE  MUST

BE AT LEAST 60”

 (1.5 m) from the center of the burner to any combustible sidewall, ceiling, or material.  

The Outdoor Fire Pit is for outdoor use only.  DO NOT install or use this appliance inside a building,
garage, or any other enclosed area or structure including recreational vehicles, boats & sheds.  

This unit must be

installed in such a manner that proper air ventilation is maintained without obstruction at all times, and during all 
weather conditions. 

B.

C.

CHECK GAS TYPE

 (Natural Gas or Propane):  The gas supply you intend to use may not be the same that your fire pit was 

setup for or is stated on your outdoor rating plate.  

THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE

 

GAS

.  If 

the gas supply is different, 

or you wish to change to Natural Gas, you MUST have the Fire Pit Converted (directions to 

convert can be found on page 12) to the gas type you intend to use.  Any gas type conversion should be performed 
by a qualified, professional technician or licensed plumber

.  If you are unsure, contact your dealer for assistance.

INSTALLER NOTE:  This unit should be installed so that it can be removed at a later date for service.

K.

Propane Regulator Hose 

(when used):   The propane regulator hose is located inside the fire pit door panel.  When 

installed, make sure the hose is secured inside the unit and 

DOES NOT TOUCH THE BURNER PAN.

L.

Propane Regulator Hose:

  Always inspect the condition of the propane regulator hose before each operation.  Any signs of 

excessive abrasion the hose MUST BE REPLACED.  Contact your local dealer for replacement part #COM0589

I.

If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 
installed before the fire pit must be closed during any pressure testing of the system at test pressures equal to or less than ½ 
psi (3.5kPa).

N.

IMPORTANT SAFETY INFORMATION 

Pre-Installation & Preparation Guidelines

If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 
installed before the fire pit and it must be closed during any pressure testing of the system at test pressures in excess of ½ 
psi (3.5kPa).  

G.

H.

DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE MAXIMUM.

J.

Note:  The Use Of A Third Party Fire Pit Top, Media and or Components Will Void the OMNI Certification
and O.W Lee Warranty. 

GAS SUPPLY PLUMBING REQUIREMENTS 

Apply only joint compounds that are resistant to all gasses on all male pipe fittings.  Make sure to tighten every joint securely.  

DO NOT use pipe joint compound to connect flare fittings

.

Содержание CASUAL FIRESIDE 51-08

Страница 1: ...t is operating burning DO NOT leave this unit operating burning when unattended If this product is left operating burning unattended it may cause serious injury or property damage BUILDING CODE AND FIXED PIPING SUPPLY REQUIREMENTS When an appliance is connected to a fixed gas piping supply system the installation must conform to local building codes or in the absence of local building codes to the...

Страница 2: ...AN CAUSE SERIOUS INJURY OR DEATH FROM FIRE BURNS EXPLOSIONS OR CARBON MONOXIDE POISONING Clearances to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensions shown in Figure 1 are MINIMUM CLEARANCES to maintain when you install this Outdoor Fire Pit THERE MUS...

Страница 3: ...y not be the same that your fire pit was setup for or is stated on your outdoor rating plate THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE GAS If the gas supply is different or you wish to change to Natural Gas you MUST have the Fire Pit Converted directions to convert can be found on page 12 to the gas type you intend to use Any gas type conversion should be performed by a qualified professio...

Страница 4: ... the fire pit top surrounding the flame and should stay away to avoid burns and clothing or long hair ignition DO NOT continue using your FIRE PIT if you smell any unusual odors or have headaches nausea or dizziness G WARNING DO NOT throw trash paper plastics or any other flammable materials into your Fire Pit WARNING DO NOT leave in operation when unattended H DO NOT use this appliance if any par...

Страница 5: ... gas at the supply LP Gas Cylinder Valve The LP Gas Cylinder must be disconnected when the appliance is not in use 4 5 6 The LP Gas Cylinder must be standing on the designed bottom base of the cylinder for proper vapor withdrawal CONNECTING AN LP GAS CYLINDER PROPANE TANK TO THE FIRE PIT Page 5 B Minimum Clearance to Combustibles Page 2 IMPORTANT BEFORE PROCEEDING CAREFULLY READ ALL OF THE IMPORTA...

Страница 6: ...ERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Note Lava granules used in a fire pit when heated up to normal operating temperatures can cause trapped gasses or moisture in the porous stone to expand and cause a pop and launch outside of the fire pit which could cause damage or injury Caution should be exercised when heating up the fire pit with lava granules to normal operating temperatures REPLACEM...

Страница 7: ...ng temperatures Figure 1 Place the largest log diagonally centered over the burner Figure 2 Place the larger three logs as desired using the largest log as the support Figure 3 Place the balance of the logs as desired Make sure to leave enough air flow CERAMIC LOG MEDIA PLACEMENT Pour the lava granules into the Outdoor Fire Pit so that the burner is completely covers the burner by 1 2 and spread e...

Страница 8: ...S SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Note Lava granules used in a fire pit when heated up to normal operating temperatures can cause trapped gasses or moisture in the porous stone to expand and may pop and launch outside of the fire p...

Страница 9: ... on Converting Your Fire Pit to a Different Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctly when finished for proper fire pit operation and safety This is a common problem when the fire pit has not been used for an extended period of time Low or Excessi...

Страница 10: ......

Страница 11: ...ied professional service technician Force or attempted repair may result in fire or explosion DO NOT use this appliance if any part has been under water Immediately call a qualified professional service technician to inspect the Outdoor Fire Pit and to replace any part of the control system and any gas control that has been under water Push in the manual gas control knob slightly and turn clockwis...

Страница 12: ...etach the flex line connector hose attached to the orifice holder Figure 1 and unscrew the orifice holder from the burner pipe Figures 1 and 2 40 3 Remove the orifice from the holder Figure 2 and replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 4 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDIC...

Страница 13: ...l Gas Code Code national du gaz É U à ANSI Z223 1 NFPA 54 Code international du gaz L installation de gaz naturel et de propane codes CSA B149 1 ou propane entreposage et de manutention Code B149 2 le cas échéant En cas d odeur de gaz UN STANDARD MEILLEUR EN QUALITÉ ET ASPECT FOYER EXÉRIEUR MAGNIFIQUE ET SANS DANGER POUR LE GAZ PROPANE ET NATUREL Kit de conversion Nécessite CASUAL FIRESIDE BTU ÉVA...

Страница 14: ... L UTILISATION DE VOTRE FEU EXTÉRIEUR PIT PEUT CAUSER DES BLESSURES GRAVES OU LA MORT DE FEU BURNS EXPLOSIONS OU AU MONOXYDE DE CARBONE INTOXICATION Parois 60 1 5 m du centre de l unité Figure 1 Plafond 60 1 5 m de haut de l unité au plafond ou faux Revêtement de sol 0 Peut être installé sur le pont la dalle le plancher etc Les dimensions indiquées dans la figure 1 sont MINIMUM DÉGAGEMENTS à maint...

Страница 15: ...PRESSION MAXIMALE EST DÉPASSÉE F Le système de tuyauterie du gaz doit être dimensionné de sorte à fournir la pression minimale d admission au débit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fireside foyers sont adaptés pour l installation à partir de 0 4500 m sans modification H Si le foyer extérieur est raccordé au gaz naturel sa v...

Страница 16: ...oyer la roche de lave ou en verre morceaux avec de l eau et sécher soigneusement avant d allumer Retirez toutes les toiles d araignée à l intérieur de l unité Effectuez périodiquement un contrôle visuel de la flamme du brûleur pour vous assurer qu il n a pas beaucoup changé en hauteur ou la coloration depuis le dernier être utilisé Toute modification significative de la hauteur de la flamme ou de ...

Страница 17: ...e LP bouteille de gaz doit être débranchée lorsque l appareil est inutilisé 4 5 6 Le cylindre de gaz propane doit être debout sur la base inférieure du cylindre conçu pour le retrait de vapeur appropriée RACCORDEMENT D UN LP BOUTEILLE DE GAZ PROPANE AU PIT FIRE Page 5 B Minimum Dégagements aux combustibles Page 2 IMPORTANT AVANT DE PROCEDER LIRE ATTENTIVEMENT TOUT LE IMPORTANT INFORMATIONS SUR LA ...

Страница 18: ...al PIÈCES DE RECHANGE ET MÉDIAS SONT DISPONIBLES SUR VOTRE CONCESSIONNAIRE nº 1 Kit de brûleur rectangle en acier inoxydable nº 2 Régulateur avec tuyau nº 3 Bouton de contrôle On Off marche arrêt nº 4 Tuyau flexible nº 5 Valve de rechange en cuivre nº 6 Connecteur de bouteille de propane nº 7 Orifice nº 8 Kit de conversion de gaz propane en gaz naturel nº 9 Kit de conversion de gaz naturel en gaz ...

Страница 19: ...s le Brasier extérieur de sorte que le brûleur est complètement recouverte Voir la Figure 1 2 et 3 Figure 1 Verser le premier sac du support de verre dans le support de brûleur Figure 2 Verser le deuxième sac de support sur le support de brûleur Spead les médias qui couvrent Evely le brûleur Bûches en céramique placement dans les médias Verser les granulés de lave dans le Foyer extérieur de sorte ...

Страница 20: ...ET SPHERE placement dans les médias Rocher Placement céramique Voir la Figure 1 2 et 3 ATTENTION brûlures ROCK CÉRAMIQUE ET CHAMP MEDIA Restera chaud pendant un certain temps après l utilisation VOUS DEVEZ conserver la disposition comme indiqué pour assurer le bon fonctionnement de votre feu PIT SI VOUS nécessité de repositionner TOUT MATÉRIEL POUR MAINTENIR l aménagement utiliser la chaleur GANTS...

Страница 21: ...et l orifice Insérez un petit fil dans le venturi et orifices des trous pour dégager le passage libre des toiles d araignées ou d autres débris Assurez vous de tout remettre correctement lorsque vous avez terminé pour le fonctionnement du foyer adéquat et la sécurité Ceci est un problème commun lorsque le foyer n a pas été utilisé pendant une longue période de temps Flamme faible ou excessive Util...

Страница 22: ... Parties Pit Fire O W Lee offre une garantie limitée de deux 2 ans sur tous les composants du brûleur en utilisation normale et appropriée entretien OW Lee sera à l usine de réparer ou de remplacer tout brûleur extérieur foyer trouvé défectueux pendant cette période de garantie Un entretien régulier doit être exercé selon dans le manuel du propriétaire Pour plus d informations consultez www owlee ...

Страница 23: ...nter une réparation peut entraîner un incendie ou une explosion NE PAS EMPLOYER cet appareil si une partie ou pièce s est trouvée sous l eau Appeler immédiatement un technicien professionnel et qualifié pour inspecter le foyer et remplacer le cas échéant des pièces du système de contrôle et de commande du gaz qui se sont trouvées sous l eau INSTRUCTIONS D ALLUMAGE STOP LIRE LES MESURES DE SÉCURITÉ...

Страница 24: ...n fonctionnement 5 IL EST NÉCESSAIRE DE POSER L ÉTIQUETTE OU LA PLAQUE SIGNALÉTIQUE INCLUSE DANS LE KIT DE CONVERSION AFIN D INDIQUER CLAIREMENT LA CONVERSION FAITE SUR PLACE Nº de série FIGURE 1 FIGURE 2 RÉSERVÉ AU FABRICANT Contrôle de la qualité Date Ordre de travail Essai de feu Volet d air X Nº d orifice PRINC 40 BTU Évaluation LP 60 000 NG 60 000 Nº d orifice AUTRE 12 COM0590CK Casual Firesi...

Отзывы: