PRE-INSTALLATION AND PREPARATION SAFETY GUIDELINES 

 

A. 

Before installing this Outdoor Fire Pit, check “Minimum Clearance to Combustibles” on page 2.  

MINIMUM

 

CLEARANCES

 must be maintained when you install this Outdoor Fire Pit.  

THERE  MUST BE AT LEAST 60”

 

(1.5 m) from the center of the burner to any combustible sidewall.  The unit 

MUST NOT BE

 installed under any 

type of ceiling or overhang. 

 
B. 

The Outdoor Fire Pit is for outdoor use only.  

DO NOT

 install or use this appliance inside a building, garage, or 

any other enclosed area including recreational vehicles and/or boats.  

This unit must be installed in such a 

manner that proper air ventilation is maintained without obstruction at all times, and during all weather 
conditions.

  

 
C. 

CHECK GAS TYPE

 (natural gas or propane):  The gas supply you intend to use may not be the same as that 

stated on your outdoor rating plate.  

THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE GAS.

  If the 

gas supply is different, or 

or you wish to change to natural gas, you MUST have the Fire Pit converted 

(method described on page 8) to the gas type you intend to use, by a qualified, professional installer.  

If 

you are unsure, contact your dealer for assistance. 

 
D. 

DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE     
MAXIMUM.

 

 
E. 

FOR NATURAL GAS:

  The minimum inlet gas supply pressure for purposes of input adjustment is 

5 inches 

(127

 

mm) water column and maximum inlet gas supply pressure is 

10 inches

 (254 mm) water column. 

FOR PROPANE:

  The minimum inlet gas supply pressure for purposes of input adjustment is 

8 inches 

(203 mm)

 

water column and the maximum inlet gas supply pressure is 

13 inches

 (330 mm) water column. 

DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS 
EXCEEDED. 

 

F. 

Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr).  Undue 
pressure loss will occur if the pipe is too small or the run is too long. 

 
G. 

For installations at elevations above 2,000 ft., contact your local dealer or gas supplier before installing as input 
ratings will be reduced approximately 4% for each 1,000 ft. above sea level.  Refer to the National Fuel Gas 
Code.  

Contact the dealer for the required orifice

 

(Also see page 8 of instructions). 

 
H. 

If the Outdoor Fire Pit is connected to Natural Gas, its main gas valve must be disconnected from the gas supply 
piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5kPa).   

I. 

If the Outdoor Fire Pit is connected to Natural Gas, it must be isolated from the gas supply piping system by 
closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test 
pressures equal to or less than ½ psi (3.5kPa). 

 
J. 

INSTALLER NOTE:  This unit should be installed so that it can be removed at a later date for service. 

 

 

K. 

GAS SUPPLY PLUMBING REQUIREMENTS 

 

Apply only joint compounds that are resistant to all gasses on all male pipe fittings.  Make sure to tighten every 
joint securely.  Do not use pipe joint compound to connect flare fittings. 
 
 

 

 
 
 
 

 
 

IMPORTANT SAFETY INFORMATION

SAFETY NOTE:  An external on/off valve in the gas line is required for safety when your Outdoor Fire Pit is 

not in use.  It also provides for convenient maintenance and repair. 

Содержание 51-05F Largo Fire Pit

Страница 1: ...21 97 2010 CGA 2 17 M91 R2009 1 OWNER S MANUAL This appliance is designed as an attended appliance Adults must be present when the unit is operating DO NOT leave this unit burning when unattended If this product is left burning unattended it may cause damage or serious injury Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cyl...

Страница 2: ... LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS OR MATERIAL IT MUST NOT BE INSTALLED UNDER ANY TYPE OF CEILING OR OVERHANG C When shutting the unit down be sure to TURN THE CONTROL VALVE FULLY OFF D WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH DO NOT MODIFY THIS OUTDOOR FIRE PIT OR ITS CONTROLS EXCEPT AS PROVIDED FOR IN THIS MANUAL Any other change may be dangerous Improper install...

Страница 3: ... of input adjustment is 8 inches 203 mm water column and the maximum inlet gas supply pressure is 13 inches 330 mm water column DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED F Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue pressure loss will occur if the pipe is too small or the run is too l...

Страница 4: ...ing or any flammable material on or near your Fire Pit Matches paper garbage or any other material must not be thrown on top of the lava rock logs or burner or into the flame I DO NOT use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been unde...

Страница 5: ...must be turned off at the supply cylinder 4 The cylinder must be disconnected when the appliance is not in use 5 The LP gas cylinders must be stored outdoors in a well ventilated area out of the reach of children Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored in a building garage or any other enclosed area 6 The cylinder supply system must be arrange...

Страница 6: ...S CRYSTALS WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Figure 2 Figure 1 PARTS LIST Replacement parts available from your local retailer LAVA GRANULE GLASS CRYSTAL INSTALL...

Страница 7: ...alified professional service technician Force or attempted repair may result in fire or explosion DO NOT use this appliance if any part has been under water Immediately call a qualified professional service technician to inspect the Outdoor Fire Pit and to replace any part of the control system and any gas control that has been under water LIGHTING INSTRUCTIONS Shutting Off the Fire Pit To turn of...

Страница 8: ...tter so that the air intake hole is open Figure 1 For natural gas slide the air shutter so that the air intake hole is closed Figure 2 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE THE FIELD CONVERSION Air intake hole open for LP Gas Open air shutter Orifice holder Connector hose Air shutter closed for Natural Gas Connector hose Orifice ...

Отзывы: