background image

Mineral Mizer Owner’s Manual (rev. 7) 

DWS-SADI  

 

Question or comments? Contact O-SO Pure at (800) OSO-PURE or 

[email protected]

Copyright

©

 2016 O-SO Pure. All rights reserved. 

Page 5 of 16 

  

             

   

(OR)

   

 

                            

Remote Dispensing Gun

           

Dispensing Gun w Coiled Hose                                    Red Faucet 

                                                (if SADI-R)                                               (if SADI-D)                                                   (if SADI Classic) 

If any items are missing or any components are damaged, contact and notify your dealer. 

 

Push-to-Connect (PTC) Fittings Primer 

The manufacturer makes extensive use of PTC fittings in the construction of this device. These fittings will last 
many leak-free years when properly cut tubing is 
properly inserted into them. Never cut tubing with a 
scissors as this crushes and deforms the new tubing 
ends. Instead, slice the tubing with a razor edge such as 
a box cutter or a tubing cutter specifically designed for 
this task. Please review the inset at right before 
continuing. 

Pre-installation Site Inspection 

Ensure that the Mineral Mizer and storage tank will fit 
into the desired location. If inside a cabinet, the Tank is 
usually placed at the back and the Mineral Mizer is 
positioned on the right side of the cabinet, providing 
maximum viewing exposure to the right & center clear 
filter sumps. If this is a Mineral Mizer II, make sure that 
it is placed within the 15 foot range of the dispensing 
gun assembly. Hand-tighten the filter sumps onto the 
Mineral Mizer head before placing it into the cabinet 
for spatial planning purposes. The filter housings must 
be removed for periodic service so keep accessibility in 
mind. 
 
 

Pay Attention to All Warnings

 

Read and adhere to all warnings contained within this manual. 

 

 

Quick Connect Fittings 

All connections are quick connect fittings except for the 
compression fitting at the inlet saddle valve, drain saddle 
valve and storage tank shutoff valve. 

To Prepare Tubing 

• Cut the tube squarely and remove any burrs. 
• Mark from the end of the tube the length of insertion. (1/4" 
O.D. - 11/16", 3/8" O.D. - 3/4") 

To Insert Tubing into Fitting 

• Insert tube straight into fitting until it bottoms out on interior 
shoulder and insertion mark is no longer visible. 

To Release Tubing 

• Push collet toward body and pull on tubing to release tube. 
To re-use fitting, begin assembly over again. 

Содержание Mineral Mizer

Страница 1: ...l rev 7 DWS SADI Question or comments Contact O SO Pure at 800 OSO PURE or support osopure com Copyright 2016 O SO Pure All rights reserved Page 1 of 16 MINERAL MIZER DEIONIZED WATER SYSTEM INSTALLATI...

Страница 2: ...Inspection 5 Pay Attention to All Warnings 5 INSTALLATION GUIDE 6 Locate the Mineral Mizer 6 Connect the Mineral Mizer to plumbing 7 OPERATING THEORY 10 SERVICING YOUR MINERAL MIZER 10 Schedule 10 Fi...

Страница 3: ...ded Introduction Congratulations on your purchase of the Mineral Mizer autoclave water system The Mineral Mizer produces deionized DI water from tap water allowing you to exit the boiled bottled disti...

Страница 4: ...Take inventory of all items supplied to ensure none are missing The box should contain the following Mineral Mizer Head Filters Spanner Wrench Filter Housings Blue 3 8 Tube Feed Water Tube w Press Reg...

Страница 5: ...he Tank is usually placed at the back and the Mineral Mizer is positioned on the right side of the cabinet providing maximum viewing exposure to the right center clear filter sumps If this is a Minera...

Страница 6: ...alve on the cold water stub plumbing Reconnect the faucet s cold water tube to the top of the Angle Stop Valve Close the Angle Stop Valve and turn on the cold water supply checking for leaks 6 Install...

Страница 7: ...responding dots on the bracket Hand tighten all the Filter Sumps so they are snug Do not use the provided filter wrench to tighten the filter Sumps unless absolutely necessary Place the Mineral Mizer...

Страница 8: ...th faucets are all CLOSED This will create enough water pressure in the system to see if there are any possible leaks coming from system Tighten the Filter Sumps with the Sump Wrench if necessary Chec...

Страница 9: ...DI filters 21 The Mineral Mizer is now ready for use To check the mineral content slide the Water Quality Monitor s switch to the FEED position Turn the monitor on by pressing its ON OFF switch The d...

Страница 10: ...s are directly affected by the RO feed water pressure and temperature The life of the membrane is determined by measuring the decline in the membrane s rejection rate over time Sans this level of meas...

Страница 11: ...lters Some possibilities include consumption by staff taking water for home use or new boiled water applications Changing Filters 1 Turn off the water supply by closing the Inline Valve on the Feed Wa...

Страница 12: ...d Thoroughly wash hands with soap before beginning installation and or sanitization procedure If your hands come into contact with any unsanitary surface while performing this procedure or the install...

Страница 13: ...NO WATER OR NOT ENOUGH WATER Feed water shut off Turn on feed water Storage tank valve shut off Open tank valve Plugged or crimped lines Remove blockage or crimp in lines Pre filter cartridge clogged...

Страница 14: ...800 OSO PURE to arrange shipment IMPORTANT To ensure proper treatment of source water purchaser must replace all filters and the UV lamp if applicable as directed in this manual Failure to service thi...

Страница 15: ...Mizer Owner s Manual rev 7 DWS SADI Question or comments Contact O SO Pure at 800 OSO PURE or support osopure com Copyright 2016 O SO Pure All rights reserved Page 15 of 16 this page intentionally lef...

Страница 16: ...der Rebate will not be applied retroactively o Only one 1 certificate may be redeemed per eligible O So Pure water system Dealer o Dealer and dealer employees are not eligible for referral fee o When...

Отзывы: