Operating Theory 

The Mineral Mizer utilizes several modern water technologies to cost-effectively purify your tap water supply 
into buffered low-mineral water for dental unit bottles, or mineral-free, autoclave-grade water. 

 

Pre-Filter 

- The yellow dot pre-filter contains a combination sediment & carbon block filter. Its function is 

to remove suspended particles, chlorine and chemicals from the feed water, reducing the incidence of 
reverse osmosis (RO) membrane clogging and chemical degradation. The pre-filter element must be 
replaced every twelve months or earlier depending on the quality of the feed water. 

 

Reverse Osmosis (RO) Module 

- The RO module contains a semi-permeable membrane. Its function is to 

divide the RO feed water into separate permeate (low mineral) and brine (high mineral) streams. This is 
accomplished by applying hydraulic pressure greater than the osmotic pressure in water containing

 

dissolved solids, effectively allowing water molecules to pass through the membrane while rejecting most 
other molecules. The productivity of the RO membrane is measured in 2 ways: 

 

water efficiency – the percentage of RO feed water that is converted to permeate water. 

 

rejection rate – the percentage of minerals rejected from the RO feed water. 

Both of these measures are directly affected by the RO feed water pressure and temperature. The life of the 
membrane is determined by measuring the decline in the membrane’s rejection rate over time. Sans this level 
of measurement, the membrane should be replaced every 24 to 36 months. (This could be earlier depending 
upon quality of feed water). 

DI Filters 

- The red dot DI filters contain two types of beads coated with ion exchange resin. One type absorbs 

molecular calcium and magnesium while the other absorbs chlorides. In exchange, the resins release hydrogen 
and hydroxide ions which combine to create additional water molecules. DI filters have a specific capacity to 
absorb minerals so the volume of DI water produced by a 2 filter set varies based on the mineral content of 
the feed water and the rejection rate of the RO membrane. The DI filters must be replaced when exhausted 
(TDS ppm > 5), and at least once annually. 

Servicing your Mineral Mizer 

Schedule 

This schedule is designed for the average potable water supply and should be followed to ensure the proper 
functioning of your Mineral Mizer. 

PART # 

SERVICE INTERVAL 

PRE-

FILTER 

DI FILTER 

RO MEMBRANE 

POST- 

FILTER 

DWS-RPKSD* 

Annual  

 

DWS-LDPF

 

Only if pre-filter clogs between 

annual service events 

 

 

 

DWS-LRDC2 

Only if TDS rises above 5 ppm 

between annual service events 

 

 

 

DWS-ROM-75HE 

3 years (2 years if TDS IN > 150 

ppm) 

 

 

 

 

 

 

 

 

 

 

These filters may be ordered by contacting the dealer through whom you purchased your Mineral Mizer. Feel 
free to contact O-SO Pure at 800-OSO-PURE (800-676-7873) for assistance in ordering from your dealer or by 
emailing your name, practice phone # and desired part # to 

[email protected]

Содержание Mineral Mizer

Страница 1: ...l rev 7 DWS SADI Question or comments Contact O SO Pure at 800 OSO PURE or support osopure com Copyright 2016 O SO Pure All rights reserved Page 1 of 16 MINERAL MIZER DEIONIZED WATER SYSTEM INSTALLATI...

Страница 2: ...Inspection 5 Pay Attention to All Warnings 5 INSTALLATION GUIDE 6 Locate the Mineral Mizer 6 Connect the Mineral Mizer to plumbing 7 OPERATING THEORY 10 SERVICING YOUR MINERAL MIZER 10 Schedule 10 Fi...

Страница 3: ...ded Introduction Congratulations on your purchase of the Mineral Mizer autoclave water system The Mineral Mizer produces deionized DI water from tap water allowing you to exit the boiled bottled disti...

Страница 4: ...Take inventory of all items supplied to ensure none are missing The box should contain the following Mineral Mizer Head Filters Spanner Wrench Filter Housings Blue 3 8 Tube Feed Water Tube w Press Reg...

Страница 5: ...he Tank is usually placed at the back and the Mineral Mizer is positioned on the right side of the cabinet providing maximum viewing exposure to the right center clear filter sumps If this is a Minera...

Страница 6: ...alve on the cold water stub plumbing Reconnect the faucet s cold water tube to the top of the Angle Stop Valve Close the Angle Stop Valve and turn on the cold water supply checking for leaks 6 Install...

Страница 7: ...responding dots on the bracket Hand tighten all the Filter Sumps so they are snug Do not use the provided filter wrench to tighten the filter Sumps unless absolutely necessary Place the Mineral Mizer...

Страница 8: ...th faucets are all CLOSED This will create enough water pressure in the system to see if there are any possible leaks coming from system Tighten the Filter Sumps with the Sump Wrench if necessary Chec...

Страница 9: ...DI filters 21 The Mineral Mizer is now ready for use To check the mineral content slide the Water Quality Monitor s switch to the FEED position Turn the monitor on by pressing its ON OFF switch The d...

Страница 10: ...s are directly affected by the RO feed water pressure and temperature The life of the membrane is determined by measuring the decline in the membrane s rejection rate over time Sans this level of meas...

Страница 11: ...lters Some possibilities include consumption by staff taking water for home use or new boiled water applications Changing Filters 1 Turn off the water supply by closing the Inline Valve on the Feed Wa...

Страница 12: ...d Thoroughly wash hands with soap before beginning installation and or sanitization procedure If your hands come into contact with any unsanitary surface while performing this procedure or the install...

Страница 13: ...NO WATER OR NOT ENOUGH WATER Feed water shut off Turn on feed water Storage tank valve shut off Open tank valve Plugged or crimped lines Remove blockage or crimp in lines Pre filter cartridge clogged...

Страница 14: ...800 OSO PURE to arrange shipment IMPORTANT To ensure proper treatment of source water purchaser must replace all filters and the UV lamp if applicable as directed in this manual Failure to service thi...

Страница 15: ...Mizer Owner s Manual rev 7 DWS SADI Question or comments Contact O SO Pure at 800 OSO PURE or support osopure com Copyright 2016 O SO Pure All rights reserved Page 15 of 16 this page intentionally lef...

Страница 16: ...der Rebate will not be applied retroactively o Only one 1 certificate may be redeemed per eligible O So Pure water system Dealer o Dealer and dealer employees are not eligible for referral fee o When...

Отзывы: