3
】
Starting up the software
・
Execute the file {CAN setting_xxxx.exe} and open the following window.
【
4
】
Confirming COM port assignment
【
5
】
Setting the COM port
【
6
】
Select ‘CAN Invalid’ or a desired baud rate from the pull-down menu (
⑥
in the above picture).
【
7
】
Click the [Save Settings](
⑧
in the above picture).
【
8
】
Turn off the ECU and turn it on again to make the setting valid.
・
Make sure which COM port is assigned to the ECU serial connection by Windows® device manager.
・
In case the assigned COM port is other than COM1
~
COM10, reassign it to one of the port from COM1
to COM10. Refer to the instruction manual of the Windows® you are using how to assign a COM port.
・
Select the confirmed COM port from the pull-down menu (
①
in the above picture).
Click the [COM
OPEN] button (
②
in the above picture) and the connection is completed.
・
In the pull-down menu of
①
, you can see what kind of connection (“USB serial port” in this sample
below) next to port number (COM3 in this case). You can make a choice from the pull-down menu. In
case you cannot find a connection, click
④
[Search again]. But some kind of RS232CtoUSB conversion
device does not show a type of connection. In this case, set a port number using Windows® device
manager.
communication protocol
・
‘125Kbps’, ‘250Kbps’, ‘500Kbps’, or ‘CAN Invalid’ can be chosen from the pull-down menu.
・
After choosing a baud rate, CAN becomes valid and the ESC sends the data at intervals of around 100ms.
With this CAN system, the data cannot be resent in case of an error.
・
Refer to page 21 about the dataformat.
23
①
②
③
⑥
⑦
⑧
⑤
④