Perimeter Intruder Detection System
The objective of these tests is to verify that the NS200M Controller is working properly.
1)
Make sure you have cleaned the connectors of LD with 99% Alcohol Solutions
and clean swipes before connecting it into the socket.
2)
Make sure you have cleaned the two SC connectors of PD1 to PD2 with 99%
Alcohol Solutions and clean swipes before connecting them into their socket.
NOTE 1:
The tip of the SC connectors are made of ceramic and are not to be
touched by bare fingers. When connecting, please ensure that the tip
does not touch the sides of the sockets!
4)
Turn system on and wait for 5 seconds.
5)
All the LED in the “TAMPER” should be GREEN. If any of the LEDs is RED,
please to check optics loop of detection.
6) Connect the controller to PC with RS232, and activate NSS for parameter setting.
7)
Please take extra care when you see the label below. Direct exposure of the
eye to the tip of connectors can caused permanent damage to the user.
SYSTEM TESTING