Nxtar NS200M Скачать руководство пользователя страница 4

Perimeter Intruder Detection System

FRONT PANEL

In

s

ta

lla

tio

n

 –

N

S

 C

o

n

tr

o

lle

r

A

B

4

TAMPER LED Indicator

When the LED is GREEN, it indicates
normal operation and there is no breach in
the

fiber connection. It also signifies that

the controller is ready for Operation. When
LED is RED, it indicates that there is a
breach somewhere in the system. This may
be tampered or damaged by intruders.
Thorough inspection is required at the
respective zone or contact your dealers and
supplier for an

inspection. User can also

refer to the operational software to detect if
tampering occurs at the Leading Fiber or
S e n s i n g F i b e r . U s e r c a n r e f e r t o
“ I n s t a l l a t i o n – S y s t e m S e t t i n g a n d
Calibration” 
for more details required.
Necessary action should be carried out
while the respective TO/TC contacts will
also be activated accordingly less than 5S.

A

INTRUDER LED Indicator

When the LED is no lighting, it indicates
normal operation and that there is no
intruder in the perimeter or the detection
zones. When the LED is RED and blinking,
it indicates that is a Warning Signal. It also
indicates that there are some unknown
project approached or touched detection
area. When the LED is RED in any zone, it
indicates that there is a intrusion in that
detection zone. Necessary action should
be carried out while the respective NO/CC
contacts will also be activated accordingly
at real time.

B

N

S

 C

o

n

tr

o

lle

r

Содержание NS200M

Страница 1: ...Instruction NS Controller Perimeter Intruder Detection System Model NS200M Security Controller NS Controller...

Страница 2: ...housed in a strong cast aluminum casing Intelligent Discrimination High performance software to calibrated the zones individually and the ability to monitor them simultaneously Equipped with Intellig...

Страница 3: ...zoom in on its present location to see and record the intrusion We at NXTAR understand that it is almost impossible to demand a perimeter especially a big one to be of the same landscape and environme...

Страница 4: ...Fiber or Sens ing Fiber User c an refer to Installation System Setting and Calibration for more details required Necessary action should be carried out while the respective TO TC contacts will also b...

Страница 5: ...sence of intruder in one of the zone TAMPER There are 2 sets of dry contacts in this row It is labeled TO1 TC1 to TO2 TC2 to trigger other devices of Zone 1 to 2 respectively if there is a tampering i...

Страница 6: ...into the output at any time during operation to as it can caused permanent damaged to the eye 5 Dry contact Status NO1 CC1 TO1 TC1 NO2 CC2 TO2 TC2 Power off Shunt Shunt Shunt Shunt Normal Open Open O...

Страница 7: ...Perimeter Intruder Detection System SYSTEM STRUCTURE Installation NS Controller ZONE 1 ZONE 2 Leading Fiber Sensing Fiber Controller SJB 7 NS Controller TJB Sensing Fiber...

Страница 8: ...The tip of the SC connectors are made of ceramic and are not to be touched by bare fingers When connecting please ensure that the tip does not touch the sides of the sockets 4 Turn system on and wait...

Страница 9: ...X 01pc 2 Relay Contact i 120Vac 10A 250Vac 7A ii 24Vdc 10A 3 Intruder LED x 02 4 Tamper LED x 02 5 Beeper x 01 9 NS Controller 5 Beeper x 01 Mechanical Spec 1 Dimension 260mm x 205mm x 44 6mm L x W x...

Страница 10: ...Perimeter Intruder Detection System DIMENSION Installation NS Controller 10 NS Controller...

Отзывы: