Fiber Optic Intrusion Detection System 

                                                 

NS-400C/600C User Manual 

 

Nxtar Fiber Optic Security Co.,Ltd.

 

6、Other 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 
 

 
 

 
 

 
 

 
 

 

 

Press Select to enter OTHER 

 

Press direction buttons to OTHER 

Press Function back to SETUP MENU 

 

Volume

Adjust the alarm sound volume from 1 to 10. 

Alarm Duration

The alarming duration when they system is tampered or the 

detection zone is intruded. The maximum duration is 99 seconds.                             

External Device

Detection Zone 1 can be integrated with other security 

equipments. When the Din pin is short, and meanwhile the zone 

threshold meets the preset value, it will not issue alarm.    When 

the Din pins are open, the system will issue alarm when the zone 

threshold meets the preset value.   

 

1

 

Press directional button to default 

2

 

Press Select into blinking status 

  and adjust value 

3

 

Activate the external device by 

  pressing UP & DOWN 

4

 

Press Select to save all setting   

 

Содержание NS-400C

Страница 1: ...Optic Security Co Ltd Fiber Optic Intrusion Detection System Fiber Optic Intrusion Detection System Fiber Optic Intrusion Detection System Fiber Optic Intrusion Detection System NS NS NS NS400C 600C 4...

Страница 2: ...rection Buttons Setting Buttons Power Switch Power Plug RS232 S USB S Main Comport RS232 M USB M Vice Comport to be connected with PC for Monitoring software I O Expansion Module CH 1 CH 6 Fiber plug...

Страница 3: ...n Introduction Introduction Introduction 1 Alarm Monitor Press Select to enter ALARM MONITOR It indicates how many counts of intrusion happen in the detection zone Press BEEP OFF to eliminate Intrusio...

Страница 4: ...elect to enter SINGAL MONITOR Press Function back to SETUP MENU Threshold Real time signals Accumulated intrigue counts 1 Count is accumulated when each the sensing signals exceeds the thresholds 2 Al...

Страница 5: ...second based unit to simulate how many seconds a intruder may go over the detection zone Count It refers to within preset Period Period Period Period how many times that signals go beyond the thresho...

Страница 6: ...ETUP MENU SF requires repair SF LF requires repair It indicates the performance of the optical path When optical path is decaying check on the glitch is required Note Note Note Note SF Sensing Fiber S...

Страница 7: ...onal button to tick detection zones 2 Press Select to group the detection zones as ticked 3 Remove the ticked zones by pressing Select Grouping function The system can filter out the unwanted global n...

Страница 8: ...tection zone is intruded The maximum duration is 99 seconds External Device Detection Zone 1 can be integrated with other security equipments When the Din pin is short and meanwhile the zone threshold...