3、Sensitivity 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 
 

 
 

 
 

 
 

 
 

 

 

Press Select to enter 

SENSITIVITY 

 

Press direction buttons to SENSITIVITY 

Parameters 

indication 

Level

:The system yields sensing signal at every 

mini second in order to simulate the signals 

transmitted by a intruder. 

 

Period:This is a second-based unit to simulate how 

many seconds a intruder may go over the 

detection zone.   

Count:It refers to within preset 

Period

Period

Period

Period

, how many 

times that signals go beyond the threshold.     

 

Only when the three parameters are met 

simultaneously, the alarms will be issued

    

Real Time 

Signals 

 

Accumulated 

intrigue counts 

 

 

1

 

Press direction button to move each item 

2

 

Press Select to enter and adjust value 

3

 

After setting, press Select to save the 

  value.   

4

 

Apply the procedure to other parameter   

setting   

 

Press Function back 

to SETUP MENU 

 

 

 

 

 

Содержание NS-400C

Страница 1: ...Optic Security Co Ltd Fiber Optic Intrusion Detection System Fiber Optic Intrusion Detection System Fiber Optic Intrusion Detection System Fiber Optic Intrusion Detection System NS NS NS NS400C 600C 4...

Страница 2: ...rection Buttons Setting Buttons Power Switch Power Plug RS232 S USB S Main Comport RS232 M USB M Vice Comport to be connected with PC for Monitoring software I O Expansion Module CH 1 CH 6 Fiber plug...

Страница 3: ...n Introduction Introduction Introduction 1 Alarm Monitor Press Select to enter ALARM MONITOR It indicates how many counts of intrusion happen in the detection zone Press BEEP OFF to eliminate Intrusio...

Страница 4: ...elect to enter SINGAL MONITOR Press Function back to SETUP MENU Threshold Real time signals Accumulated intrigue counts 1 Count is accumulated when each the sensing signals exceeds the thresholds 2 Al...

Страница 5: ...second based unit to simulate how many seconds a intruder may go over the detection zone Count It refers to within preset Period Period Period Period how many times that signals go beyond the thresho...

Страница 6: ...ETUP MENU SF requires repair SF LF requires repair It indicates the performance of the optical path When optical path is decaying check on the glitch is required Note Note Note Note SF Sensing Fiber S...

Страница 7: ...onal button to tick detection zones 2 Press Select to group the detection zones as ticked 3 Remove the ticked zones by pressing Select Grouping function The system can filter out the unwanted global n...

Страница 8: ...tection zone is intruded The maximum duration is 99 seconds External Device Detection Zone 1 can be integrated with other security equipments When the Din pin is short and meanwhile the zone threshold...

Отзывы: