UM10237_2
© NXP B.V. 2008. All rights reserved.
User manual
Rev. 02 — 19 December 2008
496 of 792
NXP Semiconductors
UM10237
Chapter 18: LPC24XX CAN controllers CAN1/2
10.2 Central Receive Status Register (CANRxSR - 0xE004 0004)
10.3 Central Miscellaneous Status Register (CANMSR - 0xE004 0008)
15:10 -
Reserved, user software should not write ones to reserved bits. The
value read from a reserved bit is not defined.
NA
16
TCS1
When 1, all requested transmissions have been completed successfully
by the CAN1 controller (same as TCS in CAN1GSR).
1
17:16 TCS2
When 1, all requested transmissions have been completed successfully
by the CAN2 controller (same as TCS in CAN2GSR).
1
31:18 -
Reserved, user software should not write ones to reserved bits. The
value read from a reserved bit is not defined.
NA
Table 438. Central Transit Status Register (CANTxSR - address 0xE004 0000) bit description
Bit
Symbol
Description
Reset
Value
Table 439. Central Receive Status Register (CANRxSR - address 0xE004 0004) bit
description
Bit
Symbol Description
Reset
Value
0
RS1
When 1, CAN1 is receiving a message (same as RS in CAN1GSR).
0
1
RS2
When 1, CAN2 is receiving a message (same as RS in CAN2GSR).
0
7:2
-
Reserved, user software should not write ones to reserved bits. The
value read from a reserved bit is not defined.
NA
8
RB1
When 1, a received message is available in the CAN1 controller (same
as RBS in CAN1GSR).
0
9
RB2
When 1, a received message is available in the CAN2 controller (same
as RBS in CAN2GSR).
0
15:10 -
Reserved, user software should not write ones to reserved bits. The
value read from a reserved bit is not defined.
NA
16
DOS1
When 1, a message was lost because the preceding message to CAN1
controller was not read out quickly enough (same as DOS in CAN1GSR).
0
17:16 DOS2
When 1, a message was lost because the preceding message to CAN2
controller was not read out quickly enough (same as DOS in CAN2GSR).
0
31:18 -
Reserved, user software should not write ones to reserved bits. The
value read from a reserved bit is not defined.
NA
Table 440. Central Miscellaneous Status Register (CANMSR - address 0xE004 0008) bit
description
Bit
Symbol Description
Reset
Value
0
E1
When 1, one or both of the CAN1 Tx and Rx Error Counters has reached
the limit set in the CAN1EWL register (same as ES in CAN1GSR)
0
1
E2
When 1, one or both of the CAN2 Tx and Rx Error Counters has reached
the limit set in the CAN2EWL register (same as ES in CAN2GSR)
0
7:2
-
Reserved, user software should not write ones to reserved bits. The
value read from a reserved bit is not defined.
NA