Equation 25
where:
• U
FOC
is the scaled FOC voltage
• U
dcbus
is the scaled measured DC-bus voltage
• U
FOC_max
is the FOC voltage scale
• U
dcbus_max
is the DC-bus voltage scale
Thus, the modulation index in the fractional representation is expressed as follows :
Equation 26
where:
• i
modfr
is the space vector modulation index in the fractional arithmetic
The
function compensates an amplitude of the direct-
α
and the
quadrature-
β
component of the stator-reference voltage vector in the fractional
arithmetic, using the formula shown in the following equations:
Equation 27
Equation 28
where:
• U
α
* is the direct-
α
duty cycle ratio
• U
β
* is the direct-
β
duty cycle ratio
• U
α
is the direct-
α
voltage
• U
β
is the quadrature-
β
voltage
Chapter 2 Algorithms in detail
GMCLIB User's Guide, Rev. 2, 10/2015