![NXP Semiconductors DSP56800E Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/nxp-semiconductors/dsp56800e/dsp56800e_user-manual_1721703028.webp)
Equation 15
Equation 16
where:
• U
α
* is the direct-
α
duty cycle ratio
• U
β
* is the direct-
β
duty cycle ratio
• U
α
is the direct-
α
voltage
• U
β
is the quadrature-
β
voltage
If the fractional arithmetic is used, the FOC and DC-bus voltages have their scales, which
take place in
Equation 17
where:
• U
FOC
is the scaled FOC voltage
• U
dcbus
is the scaled measured DC-bus voltage
• U
FOC_max
is the FOC voltage scale
• U
dcbus_max
is the DC-bus voltage scale
If this algorithm is used with the space vector modulation with the ratio of square root
equal to 3, then the FOC voltage scale is expressed as follows :
Equation 18
The equation can be simplified as follows:
GMCLIB_ElimDcBusRipFOC
GMCLIB User's Guide, Rev. 2, 10/2015
28
Freescale Semiconductor, Inc.