30
|
ELDEAN OPERATING MANUAL
NW Explorations
4F3: AC Panel 120 Volt Breakers
This section of the AC panel provides standard 120-volt
power throughout the vessel. Below are described each
breaker’s circuits and its use.
After connecting to shore power, if the Reverse Polarity Light
lights, it indicates the shore power supply is mis-wired, a
very dangerous condition that could lead to an electrical
shock, and damage the boat’s underwater gear through
electrolysis. Disconnect immediately if this occurs and advise
the marina’s officials at once!
The shore power switches are arranged so that only the
Shore Power “A” bow connector, the Shore Power “B”
Cablemaster system, or the “Ship’s Power” (generator) can
be energized at one time. To operate, slide the selector switch bar in the desired position, then throw the switch. The
upper bar connects to the boat to “A” or “B”, while the lower bar connects the boat to the Generator.
Both “Line 1” & “Line 2” are required for AC operation of the entire AC system
KEY
:
“B”
= “Breaker”
Green
=
Leave on Always
“S”
= “Switch and Breaker”
Yellow =
Use when Item is Needed
“WL” = “Warning Light”
Red
=
Use with Caution in Exceptional Circumstances
“MS” = “Momentary Switch”
*
=
Can run on Inverter
PILOT LIGHTS
Shore Power A: L1 & L2
Light if Shore Pwr “A” is live
Shore Power B: L1 & L2
Light if Shore Pwr “B” is live
Ship’s Power: L1 & L2
Light if the Generator is live
Reverse Polarity: 2 Lights See bold note above!
4F4: AC Outlet Ground Fault Interrupters
The AC outlets all have ground fault interrupters for your protection. All AC outlets in the forward part of the vessel are
protected by a GFCI breaker in the head. The AC outlets in the galley and salon are protected by a GFCI breaker to the
starboard side of the helm. There is a third GFCI breaker in the top step compartment in the companionway leading up
to the galley from the forward part of the vessel. This GFCI breaker should be left on at all times.
CIRCUIT BREAKERS
Water Heater
S
To Heater Thermostat
Air Conditioner Forward
B
To Air Conditioner
Salon Air Conditioners 1&2
B
To Air Conditioners
Battery Chargers 1 & 2
S
Turns on 12-volt Chargers
Receptacles (4)*
B
To Receptacles
Microwave*
B
To Microwave
Cooktop
B
To Cooktop in Galley
Water Maker
B
(Not used)
Engine Room Lights*
S
Turns on E/R Lights