background image

nVent.com  |  3

7

8

6B

•  Pull exposed braid back over metal clip.

•  Apply a small amout of lubricant to the jacket surface 

near the end of the cable.

•  Avoid using large amounts of lubricant on the exposed 

end of the cable.

IceStop and XL-Trace Only

•  Insert prepared heating cable 

end into connector. Push until 

heating cable is fully inserted and end is 

visible through opening in connection cover 

plate.

Note: RayClic connection kits are designed to be installed only 

once; the heating cable cannot be removed once installed

IceStop and XL-Trace

6A

HWAT Only

•  Using wire cutters, cut away 1-inch of the braid.
•  Pull exposed braid back over metal clip.

•  Using wire cutters, cut away aluminum wrap.

HWAT

Содержание RAYCHEM

Страница 1: ... Cable 877Z De Icing and Snow Melting Not UL Listed with XL Trace heating cable for buried piping APPROVED w For HWAT IceStop and XL Trace only Hazardous Locations For IceStop GM XT only Class I Div 2 Groups A B C D RayClic Connection System RayClic LE Lighted End Seal Kit Installation Instructions This component is an electrical device that must be installed correctly to ensure proper operation a...

Страница 2: ...enough extra heating cable to make service loops as required Make sure end of heating cable is cut clean Remove the outer jacket Place metal clip over the base of exposed braid For the RayClic LE lighted end seal fold up the four outer snaps then position the connector over the snaps and press down Score around and down the outer jacket of the heating cable 3 1 8 inches from the end If you experie...

Страница 3: ...nsert prepared heating cable end into connector Push until heating cable is fully inserted and end is visible through opening in connection cover plate Note RayClic connection kits are designed to be installed only once the heating cable cannot be removed once installed IceStop and XL Trace 6A HWAT Only Using wire cutters cut away 1 inch of the braid Pull exposed braid back over metal clip Using w...

Страница 4: ...ailed in steps 3 through 9 pages 2 4 Close the lid and snap the lever shut Do not force lid closed if lid does not close check the connection to ensure all screws are fully tightened Tighten the nuts on the heating cable entries until grommets are compressed Position attachment clips on mounting bracket as shown Attach the connector to the mounting bracket by pressing until it snaps in place Compl...

Страница 5: ...g cables Braid clip does not fit Be sure the clip is installed on the metal braid not on the outer jacket Heating cable does not have aluminum wrap Only HWAT heating cables have the aluminum wrap under the braid Skip the aluminum wrap removal step for XL Trace and IceStop heating cables Heating cable cannot be inserted into connector Check for the following Apply lubricant to heating cable primary...

Страница 6: ...8 Fax 86 21 5426 3167 cn thermal info nvent com Latin America Tel 1 713 868 4800 Fax 1 713 868 2333 thermal info nvent com 2018 nVent All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates All other trademarks are the property of their respective owners nVent reserves the right to change specifications without notice Raychem IM H58082 RayClicLE EN 1805 PN P0000008...

Отзывы: