SENSITIVITY 

Set the detection range using the S7 & S8 DIP switches as shown below. 
 

                              

 

 
RATINGS 

Power supply : 

 

220-240VAC 50/60Hz 

Rated Load : 

 

400W (Inductive) & 800W ( Resistive) 

Operating Temperature:  

-

25

°

C …+60

°C

 

 

FAULT FINDING 

If you experiencing a problem please check through the following before making contact with NVC: 

 

Fault - Load does not come on 

 

Check to see if the live supply to the circuit is good. 

 

If the supply & wiring are good, check the LUX setting. Increase the LUX level setting to allow the sensor to turn 
on at a higher ambient light level. 

 
Fault - Lights do not go off 

 

Ensure that the area is left unoccupied for longer than the selected timer setting. 

 

Make sure that the sensor is not adjacent to circulating air, heaters or lamps. 

 

If the unit “false triggers” reduce the SENSITIVITY level to narrow the area of detection. 

 

Ensure luminaire is not connected in parallel with other luminaires containing MW sensors 

 

Содержание SPARTAN 3CCT

Страница 1: ...e luminaire 3 Pass the mains supply cable through the cable entry hole offer the base to the mounting surface secure using the screws provided Note It is the installer s responsibility to ensure the fixing points cable entry point are appropriately sealed to maintain the IP rating 4 Route the mains supply cable to the terminal block on the gear tray terminate ensuring correct polarity is observed ...

Страница 2: ... discharge test MAINTENANCE 5 The battery pack in this luminaire must be replaced when it is no longer able to satisfy its full rated duration 6 In emergency mode the light level of the luminaire will be at a reduced output Regular maintenance and gentle cleaning is recommended so as to ensure that the Emergency Output Factor E O F remains at pre determined levels 7 Isolate the supply before servi...

Страница 3: ...ix to a vibrating surface Avoid metallic objects directly in front of the sensor head These sensor kits are capable of switching controlling more than one luminaire in a master slave set up This is done by linking non sensored fittings slaves to the one with the sensor fitted master using the live output from the sensor Note DO NOT link other fittings containing MW sensors together in this way as ...

Страница 4: ...the live supply to the circuit is good If the supply wiring are good check the LUX setting Increase the LUX level setting to allow the sensor to turn on at a higher ambient light level Fault Lights do not go off Ensure that the area is left unoccupied for longer than the selected timer setting Make sure that the sensor is not adjacent to circulating air heaters or lamps If the unit false triggers ...

Отзывы: